Technical Data
22
28.00 | DPG-plus | Assembly and Operating Manual | en | 389031
3 Technical Data
Designation
DPG-plus
Nominal working pressure [bar]
6
Min. pressure [bar]
without gripping force
maintenance
with gripping force maintenance
2.5
4.0
Max. pressure [bar]
without gripping force maintenance
with gripping force maintenance
with force intensified cylinder
8.0
6.5
6.0
Pressure range for air purge [bar]
0.2–0.5
More technical data is included in the catalog data sheet.
Whichever is the latest version.
Ambient conditions and operating conditions
Designation
DPG-plus
Ambient temperature [°C]
min.
max.
max. (variant V/HT)
+5
+90
+100 (previous version)
+130 (successor version)
IP rating*
with sinter filter (delivery state)
with ventilation connection
with Air purge connection
54
67
68
Noise emission [dB(A)]
≤ 70
* For use in dirty ambient conditions (e.g. sprayed water, vapors,
abrasion or processing dust) SCHUNK offers corresponding
product options as standard. SCHUNK also offers customized
solutions for special applications in dirty ambient conditions.