Schumacher SPI3 Скачать руководство пользователя страница 9

‡

9

‡

Find your battery’s rating on the following chart, and note the charge time given for each 

charger setting. The times given are for batteries with a 50% charge prior to recharging. 

Add more time for severely discharged batteries.

BATTERY SIZE/RATING

CHARGE RATE/ 

CHARGING TIME

3 AMP

SMALL 

BATTERIES

Motorcycle,

garden tractor, etc.

6-12 Ah

1½-2½ hrs

12-32 Ah

2½-7 hrs

CARS/TRUCKS

200-315 CCA

36-46 Ah

7½-9½ h

315-550 CCA

46-58 Ah

9½-12 h

550-1000 CCA

58-111 Ah

MAINTAIN ONLY

MARINE/DEEP-CYCLE

56 Ah

MAINTAIN ONLY

86 Ah

MAINTAIN ONLY

96 Ah

MAINTAIN ONLY

106 Ah

MAINTAIN ONLY

14. DISPLAY MESSAGES

SELECT BATTERY TYPE

1R/('OLW±:DLWLQJIRUXVHUWRVHOHFWEDWWHU\W\SH

LEAD-ACID BATTERY-PRESS AGAIN FOR LITHIUM ION

1R/('OLW±&KDUJLQJZLOO

begin for lead-acid battery type. Press again to change to lithium ion battery type.

CONNECT CLAMPS

1R/('OLW±3OXJJHGLQWRWKH$&RXWOHWZLWKRXWWKHFODPSV

connected to a battery.

WARNING CLAMPS REVERSED

1R/('OLW±3OXJJHGLQWRWKH$&RXWOHWDQGWKHFODPSV

are connected backwards to a 12V battery.

ANALYZING BATTERY

*UHHQ/('OLW±3OXJJHGLQWRWKH$&RXWOHWDQGZKHQ¿UVW

connected to a 12V battery correctly.

CHARGING 12V – XX%

*UHHQ/('OLW±3OXJJHGLQWRWKH$&RXWOHWDQGFRUUHFWO\

connected to a discharged 12V battery.

FULLY CHARGED AUTO MAINTAINING

*UHHQ/('SXOVLQJ±3OXJJHGLQWRWKH$&

outlet and correctly connected to a fully charged 12V battery.

CHARGE ABORTED-BAD BATTERY

*UHHQ/('ÀDVKLQJ±

 

Circumstances that could cause an Abort situation during charging: 

‡

The battery is severely sulfated or has a shorted cell and can’t reach a full charge.

‡

The battery is too large or there is a bank of batteries and it doesn’t reach full charge 

within a set time period.

Circumstances that could cause an Abort situation during maintain: 

‡

The battery is severely sulfated or has a weak cell and will not hold a charge.

‡

There is a large draw on the battery and the charger has to supply its maximum maintain 

current for a 12 hour period to keep the battery at full charge.

15. MAINTENANCE INSTRUCTIONS

15.1 

Cleaning and user maintenance should not be done by children without supervision.

15.2 

After use and before performing maintenance, unplug and disconnect the battery charger 

(see sections 6, 7 and 8).

15.3 

Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery 

connectors, cords, and the charger case.

15.4 

Ensure that all of the charger components are in place and in good working condition, for 

example, the plastic boots on the battery clips.

15.5 

Servicing does not require opening the unit, as there are no user-serviceable parts.

15.6 

$OORWKHUVHUYLFLQJVKRXOGEHSHUIRUPHGE\TXDOL¿HGVHUYLFHSHUVRQQHO

15.7 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 

VLPLODUO\TXDOL¿HGSHUVRQVLQRUGHUWRDYRLGDKD]DUG

Содержание SPI3

Страница 1: ...0099001439 01 SPI3 English Page 02 Deutsch Seite 15 Espa ol P gina 27 Fran ais Page 39 Italiano Pagina 51 Nederlands Pagina 63 Svenska Sidan 74...

Страница 2: ...ow you how to use your charger safely and effectively Please read understand and follow these instructions and precautions carefully as this manual contains important safety and operating instructions...

Страница 3: ...nsion cord are the same number size and shape as those of the plug on the charger That the extension cord is properly wired and in good electrical condition 7KDW WKH ZLUH VL H LV ODUJH HQRXJK IRU WKH...

Страница 4: ...acid contacts your skin or clothing immediately wash the area with soap and ZDWHU I DFLG HQWHUV RXU H H LPPHGLDWHO RRG WKH H H ZLWK FROG UXQQLQJ ZDWHU IRU DW OHDVW 10 minutes and get medical attentio...

Страница 5: ...belts pulleys and other parts that can cause injury 6 3 Check the polarity of the battery posts The POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post 6 4 Determin...

Страница 6: ...LOH DV IDU DZD IURP WKH EDWWHU DV SUDFWLFDO 7 8 A marine boat battery must be removed and charged on shore To charge it onboard requires equipment specially designed for marine use 8 AC POWER CORD CON...

Страница 7: ...ttery inside a vehicle Section 6 or outside of the vehicle Section 7 USING THE QUICK CONNECT CABLE CONNECTORS Connect any of the output cable assemblies to the charger in a matter of seconds Make VXUH...

Страница 8: ...COMPLETION OF CHARGE Charge completion is indicated by the pulsing green LED and the digital display showing FULLY CHARGED AUTO MAINTAINING This indicates the charger has switched to the Maintain Mode...

Страница 9: ...and correctly connected to a fully charged 12V battery CHARGE ABORTED BAD BATTERY UHHQ DVKLQJ Circumstances that could cause an Abort situation during charging The battery is severely sulfated or has...

Страница 10: ...is dead Poor electrical connection Check for open fuse or circuit breaker supplying AC outlet Check power cord and extension FRUG IRU ORRVH WWLQJ SOXJ Green LED is lit and the display shows ANALYZING...

Страница 11: ...s incurred by purchasers users RU RWKHUV DVVRFLDWHG ZLWK WKLV SURGXFW LQFOXGLQJ EXW QRW OLPLWHG WR ORVW SUR WV UHYHQXHV anticipated sales business opportunities goodwill business interruption and any...

Страница 12: ...ZDV DI HG LV Manufacturer Cory Watkins President July 1 2014 Hereby declares that the equipment Model SPI3 is compliant to the DIRECTIVE 2011 65 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 J...