![Schumacher SPI 16 PRO Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/schumacher/spi-16-pro/spi-16-pro_instruction-manual_1215209005.webp)
BATTERY ANALYSIS AND ERROR REPORTING
In case of anomaly the charger can report the following indications:
DISPLAY SIGNALING
CAUSE
REMEDY
The
output
clamps
are
improperly
connected to the battery.
Reverse polarity.
Position the clamps correctly and start the
charging process again. (See HOW TO USE
THE BATTERY CHARGER)
Battery with too low voltage. (You are trying
to charge a 12Volt battery with charger set
to 24V).
Battery with too high voltage. (You are
trying to charge a 24Volt battery with
charger set to 12V).
Check the battery voltage.
The battery may be defective. Consult the
nearest Battery Service Center.
Charger in error.
Have the charger checked by the nearest
Service Center.
After a certain period of time the battery is
unable to absorb current.
The battery may be defective. Consult the
nearest Battery Service Center.
Battery recovery failed after a full cycle of
desulfation.
The battery may be defective. Consult the
nearest Battery Service Center.
Disconnected cables, short circuit cables.
Position the pliers correctly and resume the
battery charge; (see paragraph “how to use
the charger").
Battery completely short circuit.
The battery may be defective. Consult the
nearest Battery Service Center.
PROTECTION
The chargers are equipped with following safety functions to ensure maximum safety during the use
and operation of the device.
Full protection against sparks
Short circuit protection
Voltage compensation
Overheat protection
Reverse polarity protection
MAINTENANCE
When not in use the charger should be kept in a dry area. For cleaning the external body of the
charger, disconnect the appliance and use a soft cloth.