BATTERY ANALYSIS AND ERROR REPORTING

  

 

In case of anomaly the charger can report the following indications: 

 

DISPLAY SIGNALING 

CAUSE 

REMEDY

 

 

The 

output 

clamps 

are 

improperly 

connected to the battery. 
Reverse polarity. 

Position  the  clamps  correctly  and  start  the 
charging process again. (See HOW TO USE 
THE BATTERY CHARGER)

 

 

Battery with too low voltage. (You are trying 
to charge a 12Volt battery  with charger set 
to 24V). 
Battery  with  too  high  voltage.  (You  are 
trying  to  charge  a  24Volt  battery  with 
charger set to 12V). 

Check the battery voltage. 
The  battery  may  be  defective.  Consult  the 
nearest Battery Service Center.

 

 

Charger in error. 

Have  the  charger  checked  by  the  nearest 
Service Center.

 

 

After  a  certain  period  of  time  the  battery  is 
unable to absorb current. 

The  battery  may  be  defective.  Consult  the 
nearest Battery Service Center.

 

 

Battery  recovery  failed  after  a  full  cycle  of 
desulfation. 

The  battery  may  be  defective.  Consult  the 
nearest Battery Service Center.

 

 

Disconnected cables, short circuit cables. 

Position  the  pliers  correctly  and  resume  the 
battery charge; (see paragraph “how to use 
the charger").

 

Battery completely short circuit. 

The  battery  may  be  defective.  Consult  the 
nearest Battery Service Center.

 

 

PROTECTION 
 

The  chargers  are  equipped  with  following  safety  functions  to  ensure maximum  safety  during the  use 
and operation of the device. 
 

 

Full protection against sparks  

 

Short circuit protection  

 

Voltage compensation  

 

Overheat protection  

 

Reverse polarity protection  

 
MAINTENANCE 
 

When  not  in  use  the  charger  should  be  kept  in  a  dry  area.  For  cleaning  the  external  body  of  the 
charger, disconnect the appliance and use a soft cloth. 

 
 
 

Содержание SPI 16 PRO

Страница 1: ...Only with charger set on RECON constant current deep charge phase and increasing voltage to increase battery charging capacity Diagnosis of battery status A2 The charger analyzes the state of efficie...

Страница 2: ...the electronic circuit inside the device will void the warranty In case of damage the power cord of the appliance must be replaced by authorized technicians since intervention requires the use of spec...

Страница 3: ...for charging AGM START STOP and AGM SPIRAL and EFB or WET batteries with temperatures below 5C 16A For charging 12V 90Ah to 360Ah batteries Maintenance for 12V 90ah to 550Ah batteries Suitable for cha...

Страница 4: ...this function This function allows you to keep the memory of a vehicle active during battery changes or in all cases where the battery is disconnected from the vehicle circuit Only in Mode 12V Warnin...

Страница 5: ...he battery is unable to absorb current The battery may be defective Consult the nearest Battery Service Center Battery recovery failed after a full cycle of desulfation The battery may be defective Co...

Страница 6: ...pecifications given by the Manufacturer insufficient care repairs carried out by persons or entities or with parts not approved by Manufacturer poor care accidents unauthorized changes or modification...

Страница 7: ...ion Centers Schumacher Europe Office in Belgium Rue de la Baronnerie 3 B 4920 Harz Belgium 32 4 388 20 17 info ceteor com Schumacher Asia Pacific Office in Australia 29 51 Wayne Goss Drive Berrinba Qu...

Отзывы: