Schumacher SPI 16 PRO Скачать руководство пользователя страница 4

 
 

For 

24V batteries

 the following charging parameters can be selected 

via the “Function" button: 

 

 4A

 

 

For charging 24V 5Ah to 80Ah batteries 
Maintenance for 24V 5Ah to 120Ah batteries 
Suitable for charging WET and Gel batteries

 

 8A

 

 

For charging 24V 50Ah to 160Ah batteries 
Maintenance for 24V 50Ah to 250Ah batteries 
Suitable for charging WET and Gel batteries

 

 4A

 

 

For charging 24V 5Ah to 80Ah batteries 
Maintenance for 24V 5Ah to 120Ah batteries 
Suitable for charging AGM-START&STOP and AGM-SPIRAL and EFB batteries 

 8A

 

 

For charging 24V 50Ah to 160Ah batteries 
Maintenance for 24V 50Ah to 250Ah batteries 
Suitable for charging AGM-START&STOP and AGM-SPIRAL and EFB batteries 

 
After selecting the appropriate 24volt function the charging process starts automatically after 5 seconds. 
 

Additional battery charger functionallity can be selected using the mode button as follows.

 

 

SHOW 
ROOM

 

SHOW ROOM

 function: 13.8 V. This function keeps vehicle accessories in operation during 

demonstrations in the dealership by supporting the connected vehicle battery. (Only in 12V mode) 

SUPPLY 

 

POWER SUPPLY

 function: 14.0 V. Press and h

old the “Mode " key for 5 sec to activate this function. 

This function allows you to keep the memory of a vehicle active during battery changes or in all cases 
where the battery is disconnected from the vehicle circuit. (Only in Mode 12V) 

Warning: in this function the charger is not protected against reverse polarization. RISK OF 
DAMAGE

!

 

 
Charging reports:

 

 

 

Battery charging. 
 

Green LED flashing. 

 

The  battery  is  100%  charged,  from  this  moment  the  charger  enters  the  maintenance  phase  and  will 
constantly monitor the state of charge of the battery, ensuring that it always remains at an optimal level. 
 
Fixed green Led.

 

 
 

INTERRUPTION OF THE CHARGE CYCLE DUE TO LOSS OF AC SUPPLY. 
 

In case of interruptions on the 230V mains line the charger stores the working cycle it was running so 
that it

 

can automatically resume when the power is returned to the 230 Volt MAINS line. This function 

is  essential  in  cases  where  the  charger  performs  charge  cycles  in  the  absence  of  an  operator;  for 
example  during  very  long  working  cycles  (maintenance  charges)  or  night  cycles  (charges  for  means 
that need daily charge cycles). 
 

END OF CHARGE 

 
1. 

Disconnect the power cord of the appliance from the mains socket 

 

2. 

Disconnect the output conductor with black clamp from the ground of the vehicle or the negative 
terminal (-) of the battery. 

 

3.       Disconnect the output conductor with red clamp from the positive terminal (+) of the battery. 

Содержание SPI 16 PRO

Страница 1: ...Only with charger set on RECON constant current deep charge phase and increasing voltage to increase battery charging capacity Diagnosis of battery status A2 The charger analyzes the state of efficie...

Страница 2: ...the electronic circuit inside the device will void the warranty In case of damage the power cord of the appliance must be replaced by authorized technicians since intervention requires the use of spec...

Страница 3: ...for charging AGM START STOP and AGM SPIRAL and EFB or WET batteries with temperatures below 5C 16A For charging 12V 90Ah to 360Ah batteries Maintenance for 12V 90ah to 550Ah batteries Suitable for cha...

Страница 4: ...this function This function allows you to keep the memory of a vehicle active during battery changes or in all cases where the battery is disconnected from the vehicle circuit Only in Mode 12V Warnin...

Страница 5: ...he battery is unable to absorb current The battery may be defective Consult the nearest Battery Service Center Battery recovery failed after a full cycle of desulfation The battery may be defective Co...

Страница 6: ...pecifications given by the Manufacturer insufficient care repairs carried out by persons or entities or with parts not approved by Manufacturer poor care accidents unauthorized changes or modification...

Страница 7: ...ion Centers Schumacher Europe Office in Belgium Rue de la Baronnerie 3 B 4920 Harz Belgium 32 4 388 20 17 info ceteor com Schumacher Asia Pacific Office in Australia 29 51 Wayne Goss Drive Berrinba Qu...

Отзывы: