USING YOUR BATTERY CHARGER

OVERVIEW

Using the battery charger is very simple.
First, connect the battery and AC power
following the precautions listed under
“OPERATING INSTRUCTIONS”. Then
select the appropriate BATTERY TYPE
and CHARGE RATE for your battery.
The Charger will then do everything
automatically. This section explains a
few details.

CHARGING: 

If the charger does not

detect a properly connected battery, the
CHECK (red) LED will light continuously
until a battery is detected. Charging will
not begin while the CHECK light is on.
When charging begins, the CHARGING
LED will be lit.

AUTOMATIC SHUT OFF:

 When the 2A,

6A, or 10A charge rate is selected, the
charger is set to perform an automatic
charge. When an automatic charge is
performed, the charger stops charging
automatically after the battery is fully
charged.

ABORTED CHARGE: 

If charging can’t

be completed normally, charging will be
aborted. When charging is aborted, the
charger’s output is shut off and the red
CHECK LED blinks on and off. In that
state, the charger ignores all buttons. To
reset the charger from after an aborted
charge, either disconnect the battery or
unplug the charger.

DESULFATION MODE:

 If a battery is

left discharged for an extended period, it
could become sulfated and not accept a
normal charge. If the charger detects a
sulfated battery, the charger will switch
to a special mode of operation designed
for such batteries. Activation of the
special desulfation mode is indicated by

blinking the CHARGING LED. If
successful, normal charging will resume
after the battery is desulfated. The
CHARGING LED will then stop blinking
and light continuously. Desulfation could
take up to 10 hours. If desulfation fails,
charging will be aborted and the CHECK
(red) LED will blink.

COMPLETION OF CHARGING:

 Charge

completion is indicated by the
CHARGED (green) LED; when lit, the
charger has stopped charging and
switched to the Maintain Mode of
operation.

MAINTAIN MODE

: When the

CHARGED (green) LED is lit, the
charger has started Maintain Mode. This
mode of operation is also known as
Float-Mode Monitoring. In this mode,
the charger keeps the battery fully
charged by delivering a small current,
when necessary. The voltage is main-
tained at a level determined by the
BATTERY TYPE selected.

GENERAL CHARGING NOTES:

If the charge mode is changed after
charging has started (by pressing the
CHARGE RATE or BATTERY TYPE
button), the charging process will be
restarted.

Содержание SpeedCharge 1000AP

Страница 1: ...product 0099000479 0105 SpeedCharge computer smart 6 10a m p F A S T C H A R G E a m p M E D I U M C H A R G E a m p S L O W C H A R G E 2 Fully Automatic Microprocessor Controlled Battery Charger ELECTRIC CORPORATION Mount Prospect IL 60056 U S A OWNER S MANUAL Model 1000AP For 12 Volt Batteries ...

Страница 2: ... not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the interfer ence by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equ...

Страница 3: ...er as far away from the battery being charged as the charger cables will permit Do not expose charger to rain or snow Never charge a frozen battery If battery fluid electrolyte becomes frozen bring battery into a warm area to allow the battery to thaw before you begin charging Never allow battery acid to drip on charger when reading specific gravity or filling battery WARNING Handling the cord on ...

Страница 4: ...ery Have plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touching your eyes while working with a battery Acid particles corrosion may get into your eyes If this occurs flush eyes immediately with running cold water for at least 10 minutes Then immediately get...

Страница 5: ...ave a 12 volt lead acid battery Determine voltage of battery by referring to vehicle owner s manual Charge battery initially at charger s lowest rate Clean the battery terminals Be careful to keep corrosion from getting in or around your eyes Wear safety glasses See additional Personal Safety Precautions on page 4 For batteries with removable vent caps if required add distilled water to each cell ...

Страница 6: ... LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the charger unplug its power cord before attempting to disconnect the output clamps Then standing away from the battery remove the output clamp from the chassis or engine block Finally remove the output clamp from the battery post 9 Clean and store the charger in a...

Страница 7: ... BATTERY 24 6 GAUGE CABLE POWER CORD TO GROUNDED POWER OUTLET CHARGING BATTERY REMOVED FROM THE VEHICLE 5 Plug power cord into an AC outlet The charger will be set to the 2 Amp for REGULAR battery type 6 Press the appropriate control buttons to select the desired charge rate and battery type The CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on check...

Страница 8: ...rine Deep cycle batteries are usually larger than the other types AGM GEL CELL AGM and gel cell batteries have sealed cases without vent caps Such batteries are often smaller than the other types 6A or 10A CHARGE RATE Use for charging automotive batteries marine batteries and deep cycle batteries Not intended for industrial applica tions With the exception of AGM and gel cell batteries all other b...

Страница 9: ...nnect the battery or unplug the charger DESULFATION MODE If a battery is left discharged for an extended period it could become sulfated and not accept a normal charge If the charger detects a sulfated battery the charger will switch to a special mode of operation designed for such batteries Activation of the special desulfation mode is indicated by blinking the CHARGING LED If successful normal c...

Страница 10: ...the charging process depends on three factors 1 Battery State If a battery has only been slightly discharged it can be charged in less than a few hours The same battery could take up to 10 hours if very weak 2 Battery rating A higher rated battery will take longer to charge than a lower rated battery under the same conditions A battery is rated in ampere hours AH reserve capacity RC and cold crank...

Страница 11: ...g Battery may be bad Charger The CHECK red light This will happen if the Reset the charger by un always flashes before the battery did not reach full plugging it or briefly discon battery is completely charge within 24 hours May necting the negative battery charged be due to a very large clip Select the desired battery or a bank of batteries charge rate and battery type requiring more power than a...

Страница 12: ...anufacturer or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages THIS IS THE ONLY EXPRESS LIMITED WARRANTY AND THE MANUFACTURER NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS EXPRESS LIMITED WA...