2. PERSONAL SAFETY PRECAUTIONS

2.1 

Wear complete eye protection and 

protective clothing when working near 

lead-acid batteries. Always have someone 

nearby for help.

2.2 

Have plenty of fresh water, soap and 

baking soda nearby for use, in case battery 

acid contacts your eyes, skin, or clothing. 

Wash immediately with soap and water 

and seek medical attention.

2.3 

If battery acid comes in contact with eyes, 

flush eyes immediately for a minimum 10 

minutes and get medical attention.

2.4 

Neutralize any acid spills thoroughly with 

baking soda before attempting to clean up. 

2.5 

Remove all personal metal items from your 

body, such as rings, bracelets, necklaces 

and watches. A battery can produce a 

short circuit current high enough to weld a 

ring to metal, causing a severe burn.

2.6 

Never smoke or allow a spark or flame in 

the vicinity of the battery or engine. 

2.7  WARNING: 

This product contains one 

or more chemicals known to the State 

of California to cause cancer and birth 

defects or other reproductive harm. 

3. FEATURES

3

5

4

6

7
8

1

2

1.

Worklight ON/OFF switch

2.

Rotary switch for USB and jump starter

3.

Built-in work light

4.

Battery status indicators

5.

Battery status button

6.

USB port

7.

12V DC power outlet

8.

Battery clamps

9.

Air compressor gauge

10.

Air compressor ON/OFF switch

11.

Internal battery charger port

12.

Air compressor hose wrap cleats

13.

Air compressor hose

14.

Air compressor adapters

and storage bag

9

14

13

10

11

12

4. CHARGING THE INTERNAL BATTERY OF THE JUMP STARTER

IMPORTANT:

  

CHARGE IMMEDIATELY AFTER 

PURCHASE, AFTER EACH USE AND 

EVERY 30 DAYS, TO KEEP THE UNIT’S 

INTERNAL BATTERY FULLY CHARGED 

AND PROLONG BATTERY LIFE.

4.1  CHECKING THE LEVEL 

OF THE INTERNAL BATTERY

Press the Battery Status button on the 

front of the unit. The LED lights will indicate 

the current charge level as follows:

RED –

 less than 20% of full charge; 

immediately charge the unit.

YELLOW/ORANGE –

 20-80% of full 

charge. 

GREEN –

 more than 80% of full charge.

4.2  CHARGING THE INTERNAL BATTERY

Charge the unit’s internal battery using an 

extension cord (not included).

NOTE:

 Use of an improper extension 

cord could result in a risk of fire and 

electric shock. 

3.

To charge, flip the AC connector on

the back of the unit DOWN and plug in

an 18 AWG or larger extension cord.

4.

Plug the extension cord into a 120VAC

electrical wall outlet.

5.

While the jump starter is charging, the 

RED LED

 will be on. Complete charging

may take up to 72 hours. When the 

RED LED

 turns off, the jump starter is 

ready to use.

Содержание SJ1331

Страница 1: ...DC Power Source OWNERS MANUAL PLEASE SAVE THIS OWNERS MANUAL AND READ BEFORE EACH USE This manual will explain how to use the portable power safely and effectively Please read and follow these instructions and precautions carefully ...

Страница 2: ...ar away from the battery being jumped as the cables will permit 1 8 Do not expose the jump starter to rain or snow 1 9 Never attempt to jump start a frozen battery 1 10 Never place the jump starter directly above battery being jumped 1 11 To prevent arcing never allow the clamps to touch together or to contact the same piece of metal 1 12 Use of an attachment not recommended or sold by Schumacher ...

Страница 3: ...us indicators 5 Battery status button 6 USB port 7 12V DC power outlet 8 Battery clamps 9 Air compressor gauge 10 Air compressor ON OFF switch 11 Internal battery charger port 12 Air compressor hose wrap cleats 13 Air compressor hose 14 Air compressor adapters and storage bag 9 14 13 10 11 12 4 CHARGING THE INTERNAL BATTERY OF THE JUMP STARTER IMPORTANT CHARGE IMMEDIATELY AFTER PURCHASE AFTER EACH...

Страница 4: ...hicle as in most vehicles connect the Instant Power s POSITIVE RED clamp to the POSITIVE POS P battery post Next connect the NEGATIVE BLACK clamp to the vehicle chassis or engine block away from the battery 4 For a positive ground vehicle connect the Instant Power s NEGATIVE BLACK clamp to the NEGATIVE NEG N battery post Next connect the POSITIVE RED clamp to the vehicle chassis or engine block aw...

Страница 5: ...ports balls 30 seconds These times are approximate Use the air compressor gauge to ensure the proper pressure has been reached Do not overinflate 6 MAINTENANCE INSTRUCTIONS 6 1 After use and before performing maintenance unplug and disconnect the jump starter 6 2 Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery clips cords and the jump starter case 6 3 Ensure th...

Страница 6: ... internal battery is not charged The 12V device draws more than 20A has a short circuit or the internal fuse has blown Turn on the 12V device Check the battery charge status by pressing the Battery Status button Disconnect the 12V device The internal 20A fuse needs replacement by a qualified service person The internal battery won t hold a charge The battery is bad will not accept a charge Have th...

Отзывы: