CHARGE RATE*/CHARGING TIME - HOURS**

2 AMP

10 AMP

30 AMP

40 AMP

60 AMP

Motorcycle, Garden

6 - 12 AH

3-6

Tractor, etc.

12 - 32 AH

3 - 18

200 - 315 CCA

40 - 60 RC

13 - 20

2 ½  - 4

½ - 1

½ - ¾

NR

315 - 550 CCA

60 - 85 RC

20 - 35

4 - 7

1 - 2

¾ - 2

½ - 1

550 - 875 CCA

85 - 125 RC

35 - 55

7 - 11

2 - 7

2 - 3

1 - 2

55 MC

34

7

NR

NR

NR

80 MC

50

10

NR

NR

NR

105 MC

66

13

NR

NR

NR

5.

If the engine fails to start, charge the battery for 5 more
minutes before attempting to crank the engine again.

6.

After the engine starts, move the charge rate switch and
timer switch to OFF and unplug the AC power cord from
the outlet before disconnecting DC clips.

Do not try to engine start a vehicle without a battery in it.
You may damage the vehicle’s system. If the engine spins,
but doesn’t start after several starting attempts, there is a
problem with the engine of the vehicle other than its start-
ing system. STOP cranking the engine until the other prob-
lem has been found and corrected.

1.

Set charge rate switch and timer to OFF positions.

2.

With the charger unplugged from the AC outlet, connect
the charger to the battery following instructions given in
section F.

3.

Plug the charger AC power cord into the AC outlet, then
move timer from OFF to HOLD position.

4.

Set the charge rate switch to the engine start position that
matches the vehicle battery and then crank the engine. Fol-
low the duty cycle printed on the front panel of your charger
for proper ON / OFF times. During extremely cold weather
or when the battery is severely exhausted, charge the bat-
tery for about 5 minutes before cranking the engine.

*Charge Rates for this model are listed on the

front panel.

**Based on battery at 50% charge.

AH

Ampere Hours

NR

Not Recommended

CCA Cold Cranking Amps
RC

Reserve Capacity

MC

Marine Capacity

SMALL
BATTERIES

CAR/TRUCKS

MARINE/
DEEP CYCLE

BATTERY SIZE/RATING

NR

NR

NR

NR

Determine the charge level of your battery with a hydrometer or electronic percent of charge tester. Determine the ampere hour rating of
your battery. It may be on the battery information label. If the battery is rated in Reserve Capacity, convert to ampere hour rating using
the following formula:

Ampere Hour rating = (Reserve Capacity) + 16

Example: AH rating = (168 Reserve Capacity) + 16

or AH = 100

   (2)

        (2)

"Reserve capacity is in minutes"

Use the following formula to determine the time of charge required: 

(AH x  % of charge needed) divided by amp setting of the charger, times

1.25 = hours of charge:

Example:

State of charge of the battery is 50%

Percent of charge needed is 100% - 50% = 50% (.50 decimal)
Ampere rating of the battery is 100AH
Charger setting is 10 amps

100 x .50

 =

x

1.25

=

6.25 hours of charge needed

10

+

1.00

hour more if charging a deep cycle battery

7.25

hours total for a deep cycle battery.

A hydrometer reading of the specific gravity of the electrolyte (fluid) of the battery in good condition should be between 1.25 and 1.28.
When a battery reaches 80-85% of full charge, bubbles will appear on the surface of the fluid. As the battery nears full charge, bubbling
will become more vigorous.

5.

Set the timer from OFF position to desired timed charge,
30-135 minutes.

NOTE:

  These battery chargers are not automatic and can

overcharge a battery if permitted to operate for extended
periods of time. Monitor the charging often.

CHARGER MUST BE ASSEMBLED BEFORE USING.

1.

Before charging any battery, make sure the electrolyte (bat-
tery liquid) in each cell is at correct level.

2.

Set all switches and timers to the OFF position.

3.

If the battery is being charged inside the vehicle, use con-
nection procedures outlined in Section F. Should the bat-
tery be removed from the vehicle, follow the instruction in
Section D, step 6 and Section G. Plug the power cord into
the AC outlet.

4.

Set the charge rate switch to the desired charge position.
See Charge Rate Charts.

I.

ENGINE START

J.

CHARGE PERIOD

K.

BATTERY CHARGING

Содержание SF-2254

Страница 1: ...d and in good electrical condition Wire size is large enough forAC ampere rating of charger as specified below Length of cord feet 25 50 100 150 AWG size of cord 16 12 10 8 American Wire Gauge 11 Always charge battery in a well ventilated area NEVER operate in a closed in or restricted area without adequate ventilation because of risk of explosive gases WARNING Risk of explosive gas 12 Locate char...

Страница 2: ...alified electrician FIGURE 1 GROUNDING METHODS DANGER Never alter the AC cord or plug provided If it will not fit outlet have a proper outlet installed by a qualified electrician Improper connection can result in a risk of an electrical shock DANGER Before using an adapter as illustrated be certain that the center screw of the outlet plate is grounded The green colored rigid ear or lug extending f...

Страница 3: ...y charger WARNING Be sure area around the battery is well ventilated while battery is being charged Gas can be forcefully blown away by using a piece of cardboard or other non metallic material as a fan 1 Check polarity of battery posts Battery case will be marked by each post POSITIVE POS P and NEGATIVE NEG N NOTE The positive battery post usually has a larger diameter than the negative post 2 At...

Страница 4: ...ch dial for those available on this charger The Ammeter indicates the amount of current measured in am peres that is being drawn by the battery For example In the 40 amp charge rate a typical discharged battery will initially draw approximately 40 amps As the battery continues to charge cur rent will taper to 15 to 20 amps at full charge The Start area of the meter indicates a high rate of current...

Страница 5: ...R NR NR Determine the charge level of your battery with a hydrometer or electronic percent of charge tester Determine the ampere hour rating of your battery It may be on the battery information label If the battery is rated in Reserve Capacity convert to ampere hour rating using the following formula Ampere Hour rating Reserve Capacity 16 Example AH rating 168 Reserve Capacity 16 or AH 100 2 2 Res...

Страница 6: ... B AXLE CAP Fig A Fig D AXLE BRACKET HUBS MUST FACE IN Fig C M TROUBLESHOOTING L ASSEMBLY INSTRUCTIONS If a problem does occur check the following PROBLEM POSSIBLE CAUSE SOLUTION No Meter Reading Clips are not making a good Rock clips back and forth for a better AC Cord Unplugged connection connection Battery voltage is too low Plug AC line into outlet Meter should now indicate 2 amp charge rate b...

Страница 7: ...if the product is misused subjected to careless handling or repaired by anyone other than the factory or other authorized factory representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages This is the only express limited warranty and the manufacturer neither assumes nor authorizes ...

Страница 8: ...8 NOTES ...

Страница 9: ...iner un courant dont l intensité répond aux exigences du chargeur Longueur de la rallonge Calibre des fils 7 6 mètres 25 pieds 16 15 2 mètres 50 pieds 12 30 5 mètres 100 pieds 10 45 7 mètres 150 pieds 8 Calibre américain de fils 11 Chargez toujours la batterie dans un endroit bien aéré Ne vous en servez JAMAIS dans un espace clos ou un endroit où l espace est restreint à moins qu il soit bien aéré...

Страница 10: ...eut être employé pour brancher la fiche du chargeur à une prise bipolaire comme le montre la figure 1 B REMARQUE L adaptateur temporaire doit être utilisé seulement jusqu à ce qu une prise mise à la terre soit installée par un électricien qualifié DANGER Ne modifiez jamais le cordon CA ni la fiche du chargeur Si la fiche ne s adapte pas à la prise de courant faites remplacer la prise par un électr...

Страница 11: ...rosserie en tôle REMARQUE Fixez les pinces aux bornes de batterie et tournez ou faites bouger les pinces de l avant vers l arrière pour assurer une bonne connexion et éviter que les pinces ne se détachent des bornes vous réduisez ainsi les risques d étincelles 6 Suivez les étapes de 1 à 4 de la section K Charge de la batterie 7 Lorsque la batterie est complètement chargée débranchez le chargeur de...

Страница 12: ...rotatif pour choisir l intensité de charge ou l aide démarrage dont vous avez besoin Lisez les indications inscrites autour du commutateur pour connaître les possibilités du chargeur L ampèremètre indique la quantité de courant mesurée en ampères et prélevée par la batterie Par exemple à une intensité de charge de 40 A une batterie type déchargée prélèvera initialement environ 40 A Tandis que la c...

Страница 13: ...otre batterie Elle peut être indiquée sur l étiquette d information de la batterie Si la capacité de réserve de la batterie est indiquée convertissez la en intensité nominale à l aide de la formule suivante Intensité nominale Capacité de réserve 16 Exemple intensité nominale capacité de réserve 168 16 ou AH 100 2 2 La capacité de réserve est en minutes Servez vous de la formule suivante pour déter...

Страница 14: ...AGE Si un problème survenait vérifiez les points suivants PROBLÈME CAUSE PROBABLE SOLUTION L ampèremètre n indique rien Les pinces ne sont pas bien raccordées Faites bouger les pinces de l avant vers l Cordon CA débranché arrière pour assurer une meilleure connexion La tension de la batterie est trop faible Branchez le cordon CA dans la prise L ampèremètre devrait alors indiquer l intensité L inte...

Страница 15: ...ulé avec négligence ou s il est réparé ailleurs qu à l usine ou chez l un des représentants agréés de l usine Le fabricant n offre aucune autre garantie que cette garantie limitée et exclut expressément toute garantie tacite incluant toute garantie pour des dommages indirects Cette garantie est la seule garantie limitée expresse et le fabricant n assume ni n autorise personne à assumer ou à contra...

Страница 16: ...8 REMARQUES ...

Отзывы: