D.

BATTERY CHARGER CONTROLS

NOTE:

 A buzz, or hum is normal when the output cables have

been disconnected and the AC power cord is still connected to
an electrical source (i.e. wall outlet).

OPERATION – Model SE-70MA

Two switches permit operation and volt selection.

Switch #1 – OPERATION SELECTOR

Mode 1 – Manual setting: Warning: This charging must be moni-
tored and stopped when the battery is charged. Overcharging
will damage the battery.

Mode 2 – Automatic setting for Conventional and Low Mainte-
nance Batteries. If you are not sure of your battery type, use the
Conventional setting.

Mode 3 – Automatic setting is for Maintenance Free and Deep
Cycle batteries.

Switch #2 – VOLT SELECTOR

Select either the 12 or 24-volt setting: Use the 12-volt setting for
a 12-volt battery and the 24-volt setting for two 12-volt batteries
hooked up in series.

MANUAL

AUTOMATIC FOR CONVENTIONAL
AND LOW MAINTENANCE BATTERIES

VOLT

SELECTOR

AUTOMATIC FOR

MAINTENANCE
FREE AND
DEEP CYCLE
BATTERIES

12 VOLT

24 VOLT

(SWITCH #1)

(SWITCH #2)

OPERATION SELECTOR

If more than one battery is to be charged, be sure the total battery
voltage is not less than that of the charger or damaged could
result to batteries and charger. Diagram for series hook up is
shown below:

Use #10 AWG jumper wires to connect batteries.

2.

Attach clamps to battery posts and twist or rock back and
forth several times to make a good connections This tends
to keep clamps from slipping off terminals and helps to
reduce risk of sparking.

1.

Connect and disconnect DC output clamps only after setting
any charger switches to off position and removing AC cord
from electric outlet. Never allow clamps to touch each other.

E.

DC CONNECTION PRECAUTIONS

A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION.
FOLLOW THESE STEPS TO REDUCE RISK OF SPARK NEAR
BATTERY:

1.

Position AC and DC cords to reduce risk of damage by hood,
door, or moving engine part.

2.

Stay clear of fan blades, belts, pulleys, and other parts that
can cause injury to persons.

3.

Check polarity of battery posts. POSITIVE (POS, P,+) battery
post usually has larger diameter than NEGATIVE (NEG, N, -
) post.

4.

Determine which post of battery is grounded (connected to
the chassis). If negative post is grounded to chassis (as in
most vehicles), see No. 5. If positive post is grounded to the
chassis, see No. 6.

5.

For a negative-grounded vehicle, connect POSITIVE (RED)
clamp from battery charger to POSITIVE (POS, P,+)
ungrounded post of battery. Connect NEGATIVE (BLACK)
clamp to vehicle chassis or engine block away from battery.
Do not connect clamp to carburetor, fuel lines, or sheet-
metal body parts. Connect to a heavy gage metal part of the
frame or engine block. (Figure 2)

6.

For a positive-grounded vehicle, connect NEGATIVE (BLACK)
clamp from battery charger to NEGATIVE (NEG, N, -)

ungrounded post of battery. Connect POSITIVE (RED) clip
to vehicle chassis or engine block away from battery. Do
not connect clamp to carburetor, fuel lines, or sheet-mebl
body parts. Connect to a heavy gage metal part of the frame
or engine block. (Figure 3)

7.

When disconnecting charger, disconnect AC cord, remove
clamp from vehicle chassis, and then remove clamp from
battery terminal, in that order.

8.

See charge period for length of charge information.

FIGURE 2:  CONNECTION TO NEGATIVE GROUNDED BATTERY

F.

FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE

GROUND

(NEG)

Содержание SE-70MA

Страница 1: ...properly wired and in good electrical condition Wire size is large enough for AC ampere rating of charger as specified below ACINPUTRATING AMPERES AWGSIZEOFCORD Equal to or but less than Length of Co...

Страница 2: ...eye protection and clothing protection when working with lead acid batteries 2 Make sure someone is within range of your voice or close enough to come to your aid when you work with or near a lead ac...

Страница 3: ...ches to off position and removing AC cord from electric outlet Never allow clamps to touch each other E DC CONNECTION PRECAUTIONS A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION FOLLOW THESE STEPS TO...

Страница 4: ...on a nominal 120 volt 60 Hz circuit I OPERATION INSTRUCTIONS 1 These battery chargers are equipped with a self resetting circuit breaker This device protects the charger from temporary overloads In th...

Страница 5: ...to zero accompanied breaker will continue to cycle and needle will by a clicking sound swing side to side until battery has recovered Battery is defective will not accept Have battery checked charge C...

Страница 6: ...subjected to careless handling or repaired by anyone other than the factory or other authorized factory representative The manufacturer makes no warranty other than this limited warranty and expressl...

Страница 7: ...7 NOTES...

Страница 8: ...l tipo de bater a que va a cargar se recomienda que seleccione tipo Convencional Modo 3 La opci n Autom tica tambi n se recomienda para bater s Libres de Mantenimiento selladas y de Ciciaje Profundo A...

Страница 9: ...conectar el cargador desconecte el cord n de la corriente AC del toma corriente y despu s quite los alicates del chasis y de la bater a en este mismo orden 8 Observe las instrucciones de trabajo para...

Страница 10: ...PROBLEMA POSIBLEEXPLICACION SOLUCION No hay lectura en el medidor Conexiones est n invertidas Con el cargador desenchufado invierte las grapas y reconecte mu valas adelante y atr s para que cojen bie...

Страница 11: ...idado o ha sido reparado por alguna persona distinta al fabricante o su representante autorizado El fabricante no efect a ninguna representaci n distinta a esta garant a limitada y expresamente excluy...

Страница 12: ...12 NOTAS...

Отзывы: