4

J.

OPERATING INSTRUCTIONS

This battery charger is equipped with a self-reseeing circuit breaker. This device protects
the charger from tempory overloads. In the event of an overload, the circuit breaker will trip
open and after a short cooling off period will reset automatically. This process is known as
cycling and can be recognized by an audible clicking sound.

K.

OUTPUT VOLTAGE SELECTOR SWITCH

Set output voltage selector switch to match voltage of battery to be charged. For models
without voltage selector switch make sure voltage of battery matches that of the charger.
Battery charger models having a voltage selector switch are for charging a 6 or 12 volt
battery. Those having no voltage switch are intended for charging a 12 volt battery or
two 6 volt batteries connected in series.

CHARGE RATE SWITCH

: Provided on model SE-50 MA-2 only. For smaller batteries, 30

AMP hours (Ah) or less, use only the 2 AMP rate. If time is not a factor, the 2 AMP rate is
also ideal for charging and maintaining larger batteries.

L.

This battery charger is equipped with an electronic control circuit which automatically gov-
ern the charge rate to your battery, (except when switch near ammeter is in its left hand
position, marked “MANUAL’ in that position  charger will not automatically shut off and user
must guard against overcharging battery).

This charger has optional charging for Low Maintenance/Conventional and Maintenance
Free/Deep Cycle batteries. These chargers employ a selector switch marked correspond-
ingly.

It is important when using this battery charger to determine initially if the battery being charged
is of (1) Maintenance Free/Deep cycle type or (2) Low Maintenance/Conventional type. Re-
fer to section Q for additional information.

Before making any connections to battery, set selector switches for type battery being charged,
read instructions F, G and H carefully.

M.

Indication of proper operation to a discharged battery but otherwise in good condition:
1. The amp meter should initially indicate the maximum output ampere rating of the charger.
2. Charge current will gradually taper to approximately one half maximum rating.
During this period the battery is approaching full charge state.
3. As the battery continues to charge the charge rate should taper to approximately 3 amp or
less. Now your battery should be fully charged.

 

 FIGURE 1

    GROUNDING METHODS

Содержание SE-3004

Страница 1: ...RATING AMPERES AWG SIZE OF CORD Equal to or but less than Length of Cord Feet 25 50 100 150 0 2 18 18 18 16 2 3 18 18 16 14 3 4 18 18 16 14 8 Do not operate charger with damaged cord or plug replace t...

Страница 2: ...ause an arc 2 Be sure area around battery is well ventilated while battery is being charged Gas can be forcefully blown away by using a piece of cardboard or other non metallic material as a fan 3 Cle...

Страница 3: ...n con nect NEGATIVE BLACK charger clip to free end of cable 5 Do not face battery when making final connection 6 When disconnecting charger always do so in reverse sequence of connecting proce dure an...

Страница 4: ...ontrol circuit which automatically gov ern the charge rate to your battery except when switch near ammeter is in its left hand position marked MANUAL in that position charger will not automatically sh...

Страница 5: ...ary materials If the battery is known to be of a calcium lead construction it should be charged with the battery charger switch in the Maintenance Free position 2 Low Maintenance and Conventional batt...

Страница 6: ...C CORPORATION 801 BUSINESS CENTER DRIVE MT PROS PECT ILLINOIS 60056 2179 MAKES THIS LIMITED WARRANTY TO THE ORIGINAL PUR CHASER AT RETAIL OF THIS PRODUCT THIS LIMITED WARRANTY IS NOT TRANSFER ABLE Sch...

Страница 7: ...S DE CORRIENTE ALTERNA Igual a la mayor que pero menos de 25 50 100 150 0 2 18 18 18 16 2 3 18 18 16 14 3 4 18 18 16 14 8 No opere el cargador con un cord n da ado cambielo inmediatamente 9 No use el...

Страница 8: ...OS CUANDO INSTALE LA BATERIA EN EL CARRO UNA CHISPA CERCADE LA BATERIA PUEDE CAUSAR UNA EXPLOSION PARAREDUCIR LOS RIESGOS DE LA CHISPA CERCA DE LA BATERIA HAGA LO SIGUIENTE 1 Sit e los cordones de cor...

Страница 9: ...es a las bater as Este cargador se apagara completamente cuando la bater a ya este cargada y se prendera automaticamente cuando la bater a necesite ser cargada nuevamente P ALMACENAMIENTO Mantengase e...

Страница 10: ...ise el voltage del interruptor si esta propiamente colocado 3 Si la corriente de descarga es menos que la proporci n de salida del cargador compruebe lo siguiente a Talvez la bater a no tiene una carg...

Отзывы: