Schumacher SCF-10000A SpeedCharge Скачать руководство пользователя страница 4

4

Never

 place charger directly above

battery being charged. The gases from
the battery will corrode and damage the
charger.

Never 

touch the battery clamps together

when the charger is on. You could
cause a spark.

Never 

operate charger if it has received

a hard blow, been dropped, or otherwise
damaged. Take it to a qualified profes-
sional for inspection and repair.

Be sure

 to position the charger power

cord to prevent it from being stepped
on, tripped over, or damaged.

Never

 pull out the plug by the cord

when unplugging the charger. Pulling on
the cord may cause damage to the cord
or the plug.

Do not

 operate the charger if it has a

damaged power cord or plug. Have the
cord replaced.

PERSONAL SAFETY PRECAUTIONS

Wear complete eye and clothing
protection 

when working with lead-

acid batteries.

Make sure 

that someone is within

range of your voice to come to your
aid if needed while you work with or
are near a lead-acid battery.

Have plenty of fresh water and
soap 

nearby for use in case battery

acid contacts your eyes, skin, or
clothing. If this happens, wash
immediately with soap and water.
Then get medical attention.

Avoid touching your eyes 

while

working with a battery. Acid particles
(corrosion) may get into your eyes. If
this occurs, flush eyes immediately
with running cold water for at least 10
minutes. Then immediately get
medical attention.

Never

 charge a frozen battery.

Remove all personal metal items

from your body such as rings,
bracelets, necklaces and watches,
while working with a lead-acid battery.
A battery can produce a short circuit
current high enough to weld a ring (or
the like) to metal, causing a severe
burn.

Take care 

not to drop any metal tool

or metal object onto the battery. This
may spark or short circuit the battery
or another electrical device that may
cause an explosion.

Always 

operate the battery charger in

an open, well-ventilated area.

Never 

smoke or allow a spark or

flame in the vicinity of the battery or
engine. Batteries generate explosive
gases.

Neutralize 

any acid spills thoroughly

with baking soda before attempting to
clean up.

Содержание SCF-10000A SpeedCharge

Страница 1: ...ctions and follow them with each use of this product 0099000450 0605 OWNER S MANUAL Schumacher Electric Corporation Mount Prospect IL 60056 U S A Model SCF 10000A For 6 and 12 Volt Batteries Send Warr...

Страница 2: ...rticular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to co...

Страница 3: ...RATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY SAVE T...

Страница 4: ...plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touching yo...

Страница 5: ...ne voltage of battery by referring to vehicle owner s manual or the battery markings Be sure to set the charger to the 6V or 12V mode accordingly Charge battery initially at charger s lowest rate Clea...

Страница 6: ...ds the CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the Charger unplug its power cord before at...

Страница 7: ...cord before attempting to disconnect the charger clamps Then standing away from the battery remove the output clamp from the CHARGING BATTERY REMOVED FROM THE VEHICLE NEGATIVE battery post Finally rem...

Страница 8: ...to set the type of battery to be charged to one of the following SCF 10000A CONTROL PANEL 12V REGULAR This is the type of battery usually used in cars trucks and motorcycles These batteries have vent...

Страница 9: ...r activated O 0 0 17 0V 2 Amp charge with battery detected O O xx or xx xV 15 Amp charge activated O O xx or xx xV 40 Amp charge activated O O xx or xx xV Charge complete Maintain Mode started O 100 o...

Страница 10: ...ed within the first ten minutes after the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTING AFTER CHARGING After the unit has been ch...

Страница 11: ...5 minutes If the charger resets it sets itself for a 2A charge and 12V REGULAR battery While waiting for cranking the digital display shows the battery voltage it can t be set to percent USING YOUR EN...

Страница 12: ...signed for such batteries Activation of the spe cial desulfation mode is indicated by blinking the CHARGING LED If suc cessful normal charging will resume af ter the battery is desulfated The CHARGING...

Страница 13: ...at period If the vehicle will only be operated for a short period short drive the battery might need to be charged again before it could start the vehicle again Reviving your battery If you only wish...

Страница 14: ...if it is determined that the battery can accept the higher rate All charging modes will decrease the charge rate as the battery approaches maximum charge After the charging process has started the di...

Страница 15: ...nnecting the negative large battery or a bank of battery clip Select the batteries requiring more desired charge rate and power than a 40 15 Amp battery type again if charger can deliver within necess...

Страница 16: ...ANUFACTURER NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS EXPRESS LIMITED WARRANTY THE MANUFACTURER MAKES NO WARRANTY OF MERCHANTABIL...

Страница 17: ...e dispositif et les observer chaque emploi 0099000450 0605 Manuel d utilisation Schumacher Electric Corporation Mount Prospect IL 60056 U S A Faire parvenir les produits r parer sous garantie Customer...

Страница 18: ...dans un type d installation sp cifique Si cet appareil cause effectivement une interf rence nuisible la r ception de la radio ou de la t l vision ce qui peut tre v rifi en allumant et en teignant l ap...

Страница 19: ...er avant de la recharger Ne laissez jamais d acide de batterie d goutter sur le chargeur lorsque vous MISE EN GARDE la manipulation du cordon de cet appareil ou du cordon des accessoires vendus avec c...

Страница 20: ...mb acide ou proximit de celle ci Ayez toujours une source d eau fra che et de savon proximit en cas d claboussure d acide dans les yeux sur la peau ou les v tements Le cas ch ant rincezimm diatementla...

Страница 21: ...tteriepourconna tre le voltage de celle ci Assurez vous de r gler le chargeur au mode 6 V ou 12 V selon le voltage de la batterie La premi re fois chargez la batterie au taux de charge le plus bas Net...

Страница 22: ...uessecondespour indiquer le d but du cycle de charge Si le voyant rouge V rifier s allume v rifiez vos branchements 8 Pour arr ter le chargeur d branchez D ABORDlecordondelaprise Ensuite en vous tenan...

Страница 23: ...e au c ble N GATIF et finalement la pince fix e la borne POSITIVE de la batterie 8 Nettoyez le chargeur et rangez le dans un endroit sec CIRCUIT DE D MARRAGE D URGENCE Ce chargeur de batterie peut au...

Страница 24: ...et por tent souvent les inscriptions Faible entretien Low Maintenance ou Sans entretien Main tenance free D CHARGE POUSS E 12 V les batteries d chargepouss eportentg n ralementlamen tion D charge pou...

Страница 25: ...terie A A 0 Voltm tre activ A 0 0 17 0 Charge de 2 A avec batterie d tect e A A xx ou xx x V Charge de 15 A activ e A A xx ou xx x V Charge de 40 A activ e A A xx ou xx x V Charge compl te Mode de mai...

Страница 26: ...ch e au chargeur Dans ce cas le chargeur reviendra aux valeurs par d faut de 2 Apour une batterie Ordinaire 12 V TESTEUR SANS LIMITE DE TEMPS Si vous appuyez sur le bouton Mode d affichage ou le bouto...

Страница 27: ...ge de surface en cr ant une demande temporaire sur la batterie du v hicule comme allumer les phares ou d autres accessoires Le pourcentage est mesur de 0 100 Le testeur de batterie est con u pour test...

Страница 28: ...ans les 5 minutes Lorsque le chargeur se r initialise il revient aux valeurs par d faut de 2 A pour une batterie Ordinaire 12 V Pendant l attente l affichage indiquera le voltage de la batterie on ne...

Страница 29: ...ation peut durer jusqu 10 heures Si la d sulfuration ne peut tre effectu e le voyant rouge V rifier se mettra clignoter FIN DU CYCLE DE CHARGE la fin du cycle de charge le voyant vert Charg e s allume...

Страница 30: ...au sujet de la charge d une batterie Lorsque l affichage montre un pourcentage de charge de 77 la batterie est suffisamment charg e pour faire d marrer la plupart des v hicules Lorsque l affichage mo...

Страница 31: ...s de puissance de charge que 40 15 A en 24 heures La batterie pourrait aussi tre d fectueuse R initialisez le chargeur en le d branchant et le rebranchant ou en d branchant bri vement la pince fix e a...

Страница 32: ...pay s au fabricant ou l un de ses repr sentants agr s Cette garantie est nulle si le produit est l objet d un usage impropre s il est manipul avec n gligence ou s il est r par ailleurs que chez le fab...

Отзывы: