Schumacher ProSeries 00-99-000742 Скачать руководство пользователя страница 7

6

the  CHARGING  (yellow)  LED  should 

light and the charging process should 

start.

7.  To disconnect the charger, unplug its 

power cord before attempting to discon-

nect the charger clamps. Then, standing 

away from the battery, remove the out-

put clamp from the NEGATIVE battery 

post. Finally, remove the output clamp 

from the POSITIVE battery post.

8. Clean and store the charger in a dry 

location.

USING ENGINE START

Your battery charger can be used to jump 

start  your  car  if  the  battery  is  low.  Fol-

low these instructions on how to use the  

ENGINE START feature.

IMPORTANT: 

Follow all safety instructions 

and precautions when charging your bat-

tery.  Wear  complete  eye  protection  and 

clothing  protection.  Charge  your  battery 

in a well-ventilated area.

IMPORTANT: 

Using the ENGINE START 

feature  WITHOUT  a  battery  installed  in 

the  vehicle  could  cause  damage  to  the 

vehicle’s electrical system.

1.  For battery connections, see page 4 and 

follow instructions 1 – 6 of CHARGING 

BATTERY IN THE VEHICLE. With the 

charger plugged in and connected to the 

battery of the vehicle, press the CHARGE 

START button until the ENGINE START 

LED  is  lit.  Only  the  ENGINE  START, 

CHARGING, CONNECTED, and VOLT-

AGE LEDs should be lit, unless the 6V  

REGULAR battery type has been se-

lected.  In that case, the 6V REGULAR 

LED will also be lit. 

2. Crank the engine for no more than 5 

seconds. If engine does not start, wait 

3 minutes before cranking again.

3. After the engine starts, unplug the power 

cord  before  disconnecting  the  output 

clamps from the battery.

4.  Clean and store the charger in a dry 

location.

NOTE:

 During the starting sequence listed 

above, the charger is set to one of three 

states. 
1.

  Wait  for  cranking

  -  The  charger 

waits until the engine is actually being 

cranked  before  delivering  125  amps 

for engine start. The charger delivers 

charge at a rate of up to 15 amps while 

waiting  and  will  reset  if  the  engine 

is  not  cranked  within  15  minutes.  (If 

the  charger  resets,  it  sets  itself  for  a 

SMALL  BATTERY  charge  and  12V  

REGULAR  BATTERY  type.)

 

While 

waiting for cranking, the digital display 

shows the battery voltage (it can’t be 

set to percent).

2.

 Cranking 

- When cranking is detected, 

the charger will automatically deliver up 

to its maximum output (at least 125A) 

as required by the starting system for 

up  to  5  seconds  or  until  the  engine  

cranking  stops.  The  digital  display 

shows a countdown of the remaining 

crank time in seconds. It starts at 5 and 

counts down to 0.

3.

 Cool Down

 - After cranking, the char-

ger enters a mandatory 3-minute (180 

second) cool down state. During this 

period, no settings can be changed. The 

buttons are ignored. The digital display 

indicates the remaining cool down time 

in seconds. It starts at 180 and counts 

down to 0. The ENGINE START LED 

blinks once every second.

 

During the 

cool down period, no current is deliv-

ered to the battery. After 3 minutes, the 

ENGINE START LED will stop blinking 

and will light continuously, indicating that 

another crank cycle can be started. The 

digital display will change from display-

ing the countdown back to displaying 

the  battery  voltage.  The  CHARGING 

LED will then be lit.

ENGINE STARTING NOTES:

•  If the battery is disconnected during 

the cool down period, the charger will 

reset. 

Содержание ProSeries 00-99-000742

Страница 1: ...S MANUAL Schumacher Electric Corporation Professional Products Division Mount Prospect IL 60056 U S A Model PSC 12500A For 6 and 12 Volt Batteries Send Warranty Product Repairs to Customer Service Re...

Страница 2: ...arefully IMPORTANT SAFETY INSTRUCTIONS 2 PERSONAL SAFETY PRECAUTIONS 3 BEFORE USING YOUR BATTERY CHARGER 3 Plugging It In 3 Assembling Your Charger 3 Using An Extension Cord 4 PREPARING YOUR BATTERY T...

Страница 3: ...LOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY save these Ins...

Страница 4: ...tely get medical attention Remove all personal metal items from your body such as rings bracelets necklaces and watches while working with a lead acid battery A battery can produce a short circuit cur...

Страница 5: ...e boat battery installed in a boat must be removed and charged on shore Using an extension cord The use of an extension cord is not rec ommended If you must use an extension cord please make sure that...

Страница 6: ...onds the CHARGING yellow LED should light and the charging process should start 8 To disconnect the charger unplug its powercordbeforeattemptingtodiscon nect the output clamps Then standing 1 Note the...

Страница 7: ...ery 4 Clean and store the charger in a dry location Note During the starting sequence listed above the charger is set to one of three states 1 Wait for cranking The charger waits until the engine is a...

Страница 8: ...y blinking the CHARGING LED If successful nor mal charging will resume after the battery is desulfated The CHARGING LED will then stop blinking and light continuously Desulfation could take up to 10 h...

Страница 9: ...les The6V REGULAR batterytypeisnotselectableforbatteries greater than 8 5V DC With the exception of AGM and gel cell batteries all other battery types may or may not have vent caps Vent caps are locat...

Страница 10: ...O 85 130 Alternator tester on bad alternator O O 0 84 131 199 Small Battery 2A charge activated O O O xx or xx x V Regular Battery 15A 40A charge activated O O O xx or xx x V Charge complete Maintain...

Страница 11: ...tester to charger if a battery is connected In that case the charger will be set for the small battery charge rate and 12V regular battery type TESTER WITHOUT TIME LIMIT If either the DIGITAL Display...

Страница 12: ...the digital display button to set the tester to Al ternator and read the alternator percent using the built in alternator tester TESTER STATUS LEDs When the PSC 12500A is operating as an alternator te...

Страница 13: ...arge rate if it is determined that the battery can accept the 40A rate All charging modes will decrease the charge rate as the battery approaches maximum charge After the charging process has started...

Страница 14: ...ur vehicle you don t need to wait for the entire charging process to be completed When the charger displays a battery of 77 or more see page 12 the battery has usually been charged enough for the vehi...

Страница 15: ...hours May be due to a very large battery or a bank of batter ies requiring more power than a 15 40 amp charger can deliver within 24 hours The battery may also be faulty Reset the charger by briefly u...

Страница 16: ...er or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages THI...

Отзывы: