Schumacher ProSeries 00-99-000742 Скачать руководство пользователя страница 10

9

CONTROL PANEL GUIDE

PSC-12500A CONTROL PANEL GUIDE

MODE OF OPERATION

Cha

rge

d

Cha

rgi

ng

Con

nec

ted

Bat

ter

y%

Vol

tag

e

Alte

rna

tor

%

12V

Reg

ula

r

12V

Dee

p-C

ycl

e

12V

AG

M,

Gel

6V

Reg

ula

r

Sm

all

Bat

ter

y

Reg

ula

rB

atte

ry

Eng

ine

Sta

rt

Digital Display

Initial power-up, battery not detected

O

O

0.0

No battery or reversed battery detected

0(%) or 0.0(V)

Battery tester activated

O

0~100

Battery tester with charged battery

O

O

O

100

Battery tester with no battery

O

0

Voltage meter activated

O

0.0~17.0

Alternator tester activated

O

0~199

Alternator tester on good alternator

O

O

O

85~130

Alternator tester on bad alternator

O

O

0~84,131~199

Small Battery (2A) charge activated

O

O

O

xx(%) or xx.x(V)

Regular Battery (15A

Ż

Ź

40A) charge activated

O

O

O

xx(%) or xx.x(V)

Charge complete - Maintain Mode started

O

O

100(%) or xx.x(V)

Engine Start

Waiting for engine crank

O

O

O

*

O

1.0~16.0

Cranking engine

O

O

*

O

5

ĺ

0

Cool down after cranking

O

*

B

180

ĺ

0

Desulfation mode activated

B

O

15(%) or 16(V)

Charge aborted

O

8.8.8 (B)

Empty spaces indicate LEDs that are off.

O indicates an LED that is on continuously.

B indicates an LED that blinks on and off.

x indicates a digit 0 ~ 9.

* indicates an LED that is on if 6V Regular is selected.

User selected

User selected

User selected

User selected

User selected

User sel.

User selected

User selected

User sel.

User sel.

User selected

User selected

User selected

User selected

User sel.

User sel.

User selected

User selected

User selected

Содержание ProSeries 00-99-000742

Страница 1: ...S MANUAL Schumacher Electric Corporation Professional Products Division Mount Prospect IL 60056 U S A Model PSC 12500A For 6 and 12 Volt Batteries Send Warranty Product Repairs to Customer Service Re...

Страница 2: ...arefully IMPORTANT SAFETY INSTRUCTIONS 2 PERSONAL SAFETY PRECAUTIONS 3 BEFORE USING YOUR BATTERY CHARGER 3 Plugging It In 3 Assembling Your Charger 3 Using An Extension Cord 4 PREPARING YOUR BATTERY T...

Страница 3: ...LOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY save these Ins...

Страница 4: ...tely get medical attention Remove all personal metal items from your body such as rings bracelets necklaces and watches while working with a lead acid battery A battery can produce a short circuit cur...

Страница 5: ...e boat battery installed in a boat must be removed and charged on shore Using an extension cord The use of an extension cord is not rec ommended If you must use an extension cord please make sure that...

Страница 6: ...onds the CHARGING yellow LED should light and the charging process should start 8 To disconnect the charger unplug its powercordbeforeattemptingtodiscon nect the output clamps Then standing 1 Note the...

Страница 7: ...ery 4 Clean and store the charger in a dry location Note During the starting sequence listed above the charger is set to one of three states 1 Wait for cranking The charger waits until the engine is a...

Страница 8: ...y blinking the CHARGING LED If successful nor mal charging will resume after the battery is desulfated The CHARGING LED will then stop blinking and light continuously Desulfation could take up to 10 h...

Страница 9: ...les The6V REGULAR batterytypeisnotselectableforbatteries greater than 8 5V DC With the exception of AGM and gel cell batteries all other battery types may or may not have vent caps Vent caps are locat...

Страница 10: ...O 85 130 Alternator tester on bad alternator O O 0 84 131 199 Small Battery 2A charge activated O O O xx or xx x V Regular Battery 15A 40A charge activated O O O xx or xx x V Charge complete Maintain...

Страница 11: ...tester to charger if a battery is connected In that case the charger will be set for the small battery charge rate and 12V regular battery type TESTER WITHOUT TIME LIMIT If either the DIGITAL Display...

Страница 12: ...the digital display button to set the tester to Al ternator and read the alternator percent using the built in alternator tester TESTER STATUS LEDs When the PSC 12500A is operating as an alternator te...

Страница 13: ...arge rate if it is determined that the battery can accept the 40A rate All charging modes will decrease the charge rate as the battery approaches maximum charge After the charging process has started...

Страница 14: ...ur vehicle you don t need to wait for the entire charging process to be completed When the charger displays a battery of 77 or more see page 12 the battery has usually been charged enough for the vehi...

Страница 15: ...hours May be due to a very large battery or a bank of batter ies requiring more power than a 15 40 amp charger can deliver within 24 hours The battery may also be faulty Reset the charger by briefly u...

Страница 16: ...er or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages THI...