background image

 

6

 

7.  FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE

A SPARK NEAR THE BATTERY MAY 

CAUSE A BATTERY EXPLOSION. TO 

REDUCE THE RISK OF A SPARK NEAR 

THE BATTERY:

7.1 

Check polarity of battery posts. POSITIVE 

(POS, P, +) battery post usually has a larger 

diameter than NEGATIVE (NEG, N, –) post.

7.2 

Attach at least a 24-inch-long 6-gauge 

(AWG) insulated battery cable to 

NEGATIVE (NEG, N, –) battery post.

7.3 

Connect POSITIVE (RED) charger clip to 

POSITIVE (POS, P, +) post of battery.

7.4 

Position yourself and free end of cable as 

far away from battery as possible – then 

connect NEGATIVE (BLACK) charger clip 

to free end of cable.

7.5 

Do not face battery when making final 

connection.

7.6 

When disconnecting charger, always do 

so in reverse sequence of connecting 

procedure and break first connection 

while as far away from battery as 

practical.

7.7 

A marine (boat) battery must be removed 

and charged on shore. To charge it on 

board requires equipment specially 

designed for marine use. 

8.  GROUNDING AND AC POWER CORD CONNECTIONS 

This battery charger is for use on a nominal 

120 volt circuit and has a grounded plug. 

The charger must be grounded, to reduce 

the risk of electric shock. The plug must 

be plugged into an outlet that is properly 

installed and grounded in accordance with 

all local codes and ordinances. The plug 

pins must fit the receptacle (outlet). Do not 

use with an ungrounded system.

DANGER:

 Never alter the AC cord or 

plug provided – if it does not fit the outlet, 

have a proper grounded outlet installed 

by a qualified electrician. An improper 

connection can result in a risk of an 

electric shock or electrocution. 

NOTE:

 Pursuant to Canadian 

Regulations, use of an adapter plug 

is not allowed in Canada. Use of an 

adapter plug in the United States is not 

recommended and should not be used.

USING AN EXTENSION CORD

The use of an extension cord is not 

recommended. If you must use an 

extension cord, follow these guidelines:

• Pins on plug of extension cord must be 

the same number, size, and shape as 

those of plug on charger.

• Ensure that the extension cord is properly 

wired and in good electrical condition.

• Wire size must be large enough for the AC 

ampere rating of charger, as specified:

Length of cord (feet)

25

50

100 150

AWG* size of cord

18

18

16

14

*AWG-American Wire Gauge

9.  ASSEMBLY INSTRUCTIONS

9.1 

Remove all cord wraps and uncoil the cables prior to using the battery charger. 

10. CONTROL PANEL

 

LED INDICATORS

 

CLAMPS REVERSED (red) LED 

flashing: 

The connections are reversed.

 

CHARGING (yellow/orange) LED lit:

 

The charger is charging the battery.

 

CHARGING (yellow/orange) LED 

flashing:

 The charger is in abort mode.

 

CHARGED/MAINTAINING (green) 

LED pulsing:

 The battery is fully charged 

and the charger is in maintain mode.

NOTE:

 See

 Operating Instructions

 for 

a complete description of the charger 

modes.

RATE SELECTION

Use this button to select one of the following:

• 

6<>2A CHARGE/MAINTAIN –  

For charging small and large batteries. Not 

recommended for industrial applications. 

The charger will automatically adjust the 

charging current, based on battery size, 

in order to charge the battery completely, 

efficiently and safely. 

• 

10A BOOST – 

For quickly adding energy 

to a severely discharged or large capacity 

battery prior to Engine Start. The unit will 

automatically switch to 6<>2A Charge/

Maintain after the 10A Boost operation 

has completed.

• 

50A ENGINE START – 

Provides 

additional amps for cranking an engine 

with a weak or run-down battery. Always 

use in combination with a battery.

Содержание FARM & RANCH FR01237

Страница 1: ...ill explain how to use the battery charger safely and effectively Please read and follow these instructions and precautions carefully POR FAVOR CONSERVE ESTE MANUAL DEL USUARIO Y LEALO ANTES DE CADA U...

Страница 2: ...LLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE 5 FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE 6 GROUNDING AND AC POWER CORD CONNECTIONS 6 ASSEMBLY INSTRUCTIONS 6 CONTROL PANEL 6 OPERATING...

Страница 3: ...NDO LA BATER A EST COLOCADA EN EL VEH CULO 13 SIGA ESTOS PASOS CUANDO LA BATER A SE ENCUENTRE FUERA DEL VEH CULO 13 CONEXIONES A TIERRA Y ENERG A DE CA 14 INSTRUCCIONES DE MONTAJE 14 PANEL DE CONTROL...

Страница 4: ...ce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery Review cautionary marking...

Страница 5: ...ff position and removing AC cord from electric outlet Never allow clips to touch each other 5 2 Attach clips to battery and chassis as indicated in the sections 6 and 7 6 FOLLOW THESE STEPS WHEN BATTE...

Страница 6: ...Regulations use of an adapter plug is not allowed in Canada Use of an adapter plug in the United States is not recommended and should not be used USING AN EXTENSION CORD The use of an extension cord...

Страница 7: ...battery clamps until a battery is properly connected The clamps will not spark if touched together BATTERY CHARGING TIMES Times are based on a 50 discharged battery and may change depending on age and...

Страница 8: ...ore cranking the engine 4 If the engine fails to start boost the battery for 5 more minutes before attempting to crank the engine again 5 After the engine starts unplug the AC power cord before discon...

Страница 9: ...ry and charger to cool down On a severely discharged battery use the 10A Boost setting for few minutes to help assist in cranking Crank time varies with the amount of current drawn If cranking draws m...

Страница 10: ...ng repaired or modified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including but not limited to express implied...

Страница 11: ...esenchufe el cargador del tomacorriente antes de intentar llevar a cabo cualquier actividad de mantenimiento o limpieza El simple apagado de los controles no reducir este riesgo 1 11 ADVERTENCIA RIESG...

Страница 12: ...hasta que el cido de la bater a alcance el nivel especificado por el fabricante de la bater a No provoque derrames En lo que concierne a bater as que no cuentan con tapas extra bles para pilas tales...

Страница 13: ...eh culo o al bloque motor alejado de la bater a No conecte al carburador l neas de combustible o cuerpos met licos Conecte a una pieza met lica de calibre grueso del marco o del bloque motor 6 7 Al de...

Страница 14: ...e extenso para el calibre de amperios del cargador de CA como se especifica a continuaci n Longitud del cable pies 25 50 100 150 Calibre del cable AWG 18 18 16 14 AWG American Wire Gauge 9 INSTRUCCION...

Страница 15: ...a las pinzas de la bater a hasta que la bater a est apropiadamente conectada Significado las pinzas no har n corto si se juntan una con otra TIEMPOS DE CARGA Los tiempos est n basados en un 50 descar...

Страница 16: ...nutos antes de intentarlo de nuevo NOTA Bajo clima fr o extremo o si la bater a es inferior a 2 volts utilizar el ajuste Boost 10A por 5 minutos antes de poner en marcha el motor 4 Si el motor no arra...

Страница 17: ...or a el ndice de arranque del motor El cargador podr a encontrarse en estado de recalentamiento Verifique la posible presencia de fusibles abiertos o disyuntores que suministren energ a al tomacorrien...

Страница 18: ...zados con este producto que no sean los fabricados por Schumacher Electric Corporation y que no est n aprobados para su uso con este producto La presente Garant a Limitada ser nula si el producto se u...

Страница 19: ...e Purchased____________________ Date of Purchase__________ Store Location_____________________ UPC Number_________________________ Serial Number_______________________________________ SEE PRODUCT For...