Schumacher 101-7 Скачать руководство пользователя страница 6

• 6 •

4.  Crank the engine until it starts or 7 seconds pass. If the engine does not start, repeat. Do not crank 

during the cool down period (see below). This allows the charger and battery to cool down. NOTE: 

During extremely cold weather, or if the battery is under 2 volts, charge the battery for 5 minutes 

before cranking the engine.

5.  If the engine fails to start, charge the battery for 5 more minutes before attempting to crank the engine again.

6.  After the engine starts, unplug the AC power cord before disconnecting the battery clamps from the vehicle.

7.  Clean and store the charger in a dry location.

NOTE: If the engine does turn over but never starts, there is not a problem with the starting system; 

there is a problem somewhere else with the vehicle. STOP cranking the engine until the other problem has 

been diagnosed and corrected.
ENGINE STARTING NOTES

During the starting sequence listed above, the charger is set to one of four states:

• Wait for ready – The charger charges the battery for 2 minutes before the Wait for Cranking state. 

While waiting for ready, the engine can be cranked. For severely discharged batteries, it is not 

recommended to crank during this time.

• Wait for cranking – The charger waits until the engine is actually being cranked before delivering the 

amps for engine start. 

• Cranking – When cranking is detected, the charger will automatically deliver up to its maximum output 

as required by the starting system for up to 7 seconds. 

• Cool Down – After repeated cranking during a 3-minute ready period, the charger enters a mandatory 

3 minute (180 second) cool down state. After 2 hours of Engine Starting, the unit will automatically exit 

from the charging mode, just as if the STOP button had been pressed; the ON LED will not be lit.

POWER-UP AUTO-START

This charger is equipped with an auto-start feature, which is triggered only when the charger is first 

powered up. If the START button is not pressed within 30 seconds, the unit will search for a battery. If the 

unit detects a battery that is properly connected, the unit will set the rate to Boost, and it will automatically 

start the charge process. The On (yellow/orange) LED will light. 
FAN OPERATION

The fan will operate as needed and it is normal for the fan to sometimes operate continuously. Keep the 

area near the charger clear of obstructions to allow the fan to operate efficiently.

12.  MAINTENANCE AND CARE

A minimal amount of care can keep your battery charger working properly for years.

• Clean the clamps each time you are finished charging. Wipe off any battery fluid that may have come 

in contact with the clamps to prevent corrosion.

• Occasionally cleaning the case of the charger with a soft cloth will keep the finish shiny and help 

prevent corrosion.

• Coil the input and output cords neatly when storing the charger. This will help prevent accidental damage 

to the cords and charger.

• Store the charger unplugged from the AC power outlet in an upright position.  

• Store inside, in a cool, dry place. Do not store the clamps on the handle, clipped together, on or around 

metal, or clipped to the cables.

Содержание 101-7

Страница 1: ...RATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER b To reduce risk of battery explosion follow these instructions and those published by...

Страница 2: ...in any way 4 5 Do not set a battery on top of charger 5 DC CONNECTION PRECAUTIONS 5 1 Connect and disconnect DC output clips only after setting any charger switches to off position and removing AC co...

Страница 3: ...o not use with an ungrounded system 8 2 DANGER Never alter the AC cord or plug provided if it does not fit the outlet have a proper grounded outlet installed by a qualified electrician An improper con...

Страница 4: ...tlet 8 Select the charge rate 9 Press the START button to begin charging immediately If START button is not pressed within thirty seconds after unit was first powered up and the charger detects a batt...

Страница 5: ...tinuous 12 hour period it will go into abort mode seeAborted Charge section This is usually caused by a drain on the battery or the battery could be bad MAINTAINING A BATTERY This unit charges and mai...

Страница 6: ...p to 7 seconds Cool Down After repeated cranking during a 3 minute ready period the charger enters a mandatory 3 minute 180 second cool down state After 2 hours of Engine Starting the unit will automa...

Страница 7: ...ry or 5V for a 6V battery after 2 hours of charging The charger cannot desulfate the battery The battery was unable to reach the full charge voltage The charger was unable to keep the battery fully ch...

Страница 8: ...ccessories used with this product that are not manufactured by Schumacher Electric Corporation and approved for use with this product This Limited Warranty is void if the product is misused subjected...