Schumacher Electric XI41DU Скачать руководство пользователя страница 6

• 5 •

Plug the device into the inverter AC outlet.

3. 

Press and hold the ON/OFF 

4. 

 switch to turn the inverter on. 

(The internal speaker will make a brief “beep”. This is normal.) 

The Wattage out   LED will glow and the digital display will 

show 

.

Turn the device on. The display will now show the total 

5. 

wattage used by the device. To change the digital display, 

press the Display 

 button.

To disconnect, reverse the above procedure.

6. 

NOTE:

 If more than one device is to be powered, start one device 

at a time to avoid a power surge and overloading the inverter. 

The surge load of each device should not exceed the inverters 

Continuous Operation wattage rate.

If there is a short circuit or power surge in the 

device, 



 will display and the alarm will sound. Press the ON/

OFF   switch to turn off the alarm. If the 



 displays after several 

attempts, there is a short circuit or the device requires more 

“starting” or “peak” load than the inverter is capable of providing.

NOTE:

 After two 



 events the inverter will go into a mandatory 10 

second cool down period before it will turn on again.

 If you are using the power inverter to operate a 

battery charger, monitor the temperature of the battery charger for 

about 10 minutes. If the battery charger becomes abnormally 

warm, disconnect it from the inverter immediately.

NOTE:

 You can use an extension cord from the inverter to the 

device without significantly decreasing the power being generated 

by the inverter. For best operating results, the extension cord 

should be no longer than 50 feet.

Using the USB Port 

The USB port provides up to 500mA at 5V DC.

Plug the device into the USB port.

1. 

Press and hold the ON/OFF 

2. 

 switch to turn the inverter on. 

(The internal speaker will make a brief “beep”. This is normal.)

Turn the USB device on.

3. 

Reverse these steps when finished using the USB port.

4. 

Содержание XI41DU

Страница 1: ...l del usuario READ THE ENTIRE MANUAL BEFORE USING THIS PRODUCT FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH ADVERTENCIA LEA EL MANUAL COMPLETO ANTES DE UTILIZAR ESTE PRODUCTO CUALQUIER FAL...

Страница 2: ...o the operator or bystanders Indicates a potentially hazardous situation which if not avoided could result in moderate or minor injury to the operator or bystanders Indicates a potentially hazardous s...

Страница 3: ...onnecting to a 6 volt or 16 volt battery will cause damage to the inverter Make sure the AC plug connection is tight 1 11 Do not modify the inverter in any way including cables plugs or 1 12 switches...

Страница 4: ...cessory port this inverter is designed to supply 60 to 70 watts when the vehicle is not running With the vehicle s engine running it can supply up to 100 watts To use the full output you must connect...

Страница 5: ...Connecting inverter cables to 12v battery or 12v power source Keep hands hair clothing and jewelry clear of battery terminals 1 Wear eye protection and clothing protection 2 Connect the positive red...

Страница 6: ...r several attempts there is a short circuit or the device requires more starting or peak load than the inverter is capable of providing NOTE After two SC events the inverter will go into a mandatory 1...

Страница 7: ...most electronic supply stores NOTE You may hear a buzzing sound being emitted from inexpensive sound systems when operated with the inverter This is due to ineffective filters in the sound system s p...

Страница 8: ...age drops below 15 0 volts The continuous load demand from the device exceeds the inverter s wattage output The inverter is overheated and automatically turns off for a period of 1 to 3 minutes to coo...

Страница 9: ...surge power Display shows 12 volt battery is too low Display shows voltage in between 10 5 and 11 0 volts Cycle the inverter power OFF and ON If problem persists use a larger inverter or a smaller de...

Страница 10: ...e alternator or charging system Use a properly sized and rated 12 volt battery If the input voltage returns to 15 volts or less the inverter will automatically restart Cycle the inverter power OFF and...

Страница 11: ...a qualified service technician who will diagnose the inverter and replace the fuse s with the appropriate replacement s See warranty and call Customer Service 1 800 621 5485 Hours 7 00 am to 5 00 pm...

Страница 12: ...DC High Voltage Shutdown Over 15 5V 0 5V DC AC Receptacle Two NEMA 5 15 USA USB Port One 0 5A 5V DC Dimensions 5 L x 4 W x 2 2 H Weight Approximately 2 lbs Model XI75DU Maximum Continuous Output 750 W...

Страница 13: ...our product with a new or reconditioned unit at the option of the Manufacturer It is the obligation of the purchaser to forward the unit along with mailing charges prepaid to the Manufacturer or its a...

Страница 14: ...fic legal rights and it is possible you may have other rights which vary from this warranty THIS LIMITED WARRANTY IS THE ONLY EXPRESS LIMITED WARRANTY AND THE MANUFACTURER NEITHER ASSUMES OR AUTHORIZE...

Страница 15: ...cause it will be required for any warranty claims This warranty is not transferable Mail To Schumacher Electric Corporation 801 Business Center Drive Mount Prospect IL 60056 2179 Name_________________...

Страница 16: ...l le otorga todo derecho a cualquier reclamo de garant a Esta garant a no es tranferible Dirigase a Schumacher Electric Corporation 801 Business Center Drive Mount Prospect IL 60056 2179 Nombre_______...

Страница 17: ...ialmente riesgoso que si no se evita podr a resultar o de serios perjuicios al operador o personas alrededor Indica una situaci n potencialmente peligrosa que de no evitarse podr a resultar en menores...

Страница 18: ...agua y muchos otros l quidos pueden conducir electricidad lo cual puede llevar a una lesi n seria o la muerte No coloque el convertidor sobre o cerca de ventilas de calefac 1 8 ci n radiadores u otra...

Страница 19: ...mpatible con una onda senoidal modificada Para calcular el vataje Vataje AMPS x 120 Voltaje CA Para calcular la carga de arranque Carga de Arranque 2 x WATTS En general la carga de arranque del dispos...

Страница 20: ...er as sin tranformador 9 Al hacerlo podr a operar el aparato bajo intenso calor y sobrecalentarlo PARA CONECTAR LOS CABLES DEL Inversor 3 El Inversor y la fuente de energ a deben estar en el modo APAG...

Страница 21: ...s conexiones correctas resultar en fusibles quemados y da o permanente el Inversor INSTRUCCIONES DE OPERACI N 4 Conecte el Inversor ver la secci n PARA CONECTAR LOS 1 CABLES DEL INVERSOR Aseg rese de...

Страница 22: ...or al aparato sin disminuir la carga generada por el inversor Para obtener mejores resultados en la operaci n la extension no debe sobrepasar 50 pies de largo El uso de Puerto USB El puerto USB provee...

Страница 23: ...Lamentablemente este problema solamente puede ser resuelto comprando un sistema de sonido con una calidad m s alta de abastecimiento de sonido o un filtro de m s alta calidad FUENTE DE ENERG A 5 Su b...

Страница 24: ...de la bater a del veh culo es m s de 15 5 voltios El inversor autom ticamente se reactivar despu s de que el voltaje baje a hasta a menos de 15 0 voltios Hip La demanda continua de carga del aparato e...

Страница 25: ...e corregir la causa del fusible quemado antes de usar el convertidor de nuevo RESOLUCI N DE PROBLEMAS 8 PROBLEMA CAUSA POSIBLE SOLUCION La alarma est encendida El indicador muestra SC El aparato tiene...

Страница 26: ...12V est baja Recargue reemplace la bater a El inversor se apagar autom ticamente cuando el voltaje de la bater a alcance 10 5 voltios Si el veh culo necesita reparaci n reemplazar el alternador o car...

Страница 27: ...El Inversor puede estar defectuoso Revise las conexiones a la bater a o de la fuente de poder Aseg rese que las puntas est n bien limpias Remueva rozando las pinzas para una mejor conexi n Una conexi...

Страница 28: ...Continua 500 Watts Capacidad de Tensi n 0 1 segundos 1000 Watts ptima Eficiencia 85 Consumo de Corriente en Vac o 0 5A Forma de Onda de Salida Onda Senoidal Modificada mbito de Tensi n de Salida 120V...

Страница 29: ...ESTA GARANT A LIMITADA NO ES TRANSFERIBLE O ASIGNABLE Schumacher Electric Corporation el Fabricante garantiza este Inversor por dos a os a partir de la fecha de compra al menudeo contra material defe...

Страница 30: ...luidas en el este est n por el presente expresamente denegadas y excluidas Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o de consecuencia o el largo de la garant a impl...

Отзывы: