MAINTAINING A BATTERY

The SC15 charges and maintains 12 volt 

batteries, keeping them at full charge. 

NOTE:

 The maintain mode technology 

allows you to safely charge and maintain 

a healthy battery for extended periods 

of time. However, problems with the 

battery, electrical problems in the 

vehicle, improper connections or other 

unanticipated conditions could cause 

excessive current draws. As such, 

occasionally monitoring your battery and 

the charging process is required. 

12. MAINTENANCE AND CARE

A minimal amount of care can keep your 

battery charger working properly for years.

• Clean the clamps each time you are 

finished charging. Wipe off any battery 

fluid that may have come in contact with 

the clamps to prevent corrosion.

• Occasionally cleaning the case of the 

charger with a soft cloth will keep the 

finish shiny and help prevent corrosion.

• Coil the input and output cords neatly 

when storing the charger. This will help 

prevent accidental damage to the cords 

and charger.

• Store the charger unplugged from the AC 

power outlet in an upright position.  

• Store inside, in a cool, dry place. Do not 

store the clamps on the handle, clipped 

together, on or around metal, or clipped 

to the cables.

13. TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

REASON/SOLUTION

Charger will not turn 

on when properly 

connected.

AC outlet is dead.

Poor electrical connection.

Battery is defective.

Check for open fuse or circuit breaker 

supplying AC outlet.

Check power cord and extension cord 

for loose fitting plug.

Have the battery checked.

The Boost-Charging  

LED is flashing.

The charger has stopped in 

Boost or Charge mode.

The battery is bad.

The charger cannot complete the boost 

or charge. Have the battery checked and 

replace, if necessary.

Disconnect charger from the AC outlet and 

then remove the clamps. Do not continue 

to try to charge the battery. Have the 

battery checked and replace, if necessary.

The Boost-Charging  

LED does not turn off.

The charger is still in Boost or 

Charge mode.

This is normal. The Boost-Charging 

LED will not turn off until the battery is 

disconnected from the charger.

Charger does not 

detect a low voltage 

battery.

The charger was on for more 

than 5 minutes before it was 

connected to the battery.

The clamps are active for only the first 5 

minutes. Switch to the OFF position and 

connect the charger to the battery. Set 

the switch to the Boost/Charge/Maintain 

position. Then push the rate selection 

button to turn on the charger.  

Engine start does  

not work. 

Drawing more than 200 amps.

Failure to wait 3 minutes (180 

seconds) between cranks.

The charger may be 

overheated. 

Battery may be severely 

discharged. 

Crank time varies with the amount of 

current drawn. If cranking draws more 

than 200 amps, crank time may be less 

than 5 seconds.

When the Engine Start LED blinks, wait 3 

minutes of rest time before the next crank.

The thermal protector may have tripped 

and needs a little longer to reset. Make 

sure the charger vents are not blocked. 

Wait and try again.

On a severely discharged battery, use the 

40A Boost rate for 10 to 15 minutes, to 

help assist in cranking.

Содержание SC1285

Страница 1: ...e instructions and precautions carefully POR FAVOR CONSERVE ESTE MANUAL DEL USUARIO Y LEALO ANTES DE CADA USO En este manual le explica c mo utilizar el cargador de bater a de manera segura y confiabl...

Страница 2: ...NS 9 LIMITED WARRANTY 9 WARRANTY CARD 19 CONTENIDOS INSTRUCCIONES IMPORTANTES DE SEGURIDAD 10 PRECAUCIONES DE SEGURIDAD PERSONAL 10 PREPARACI N PARA LA CARGA 11 UBICACI N DEL CARGADOR 11 PRECAUCIONES...

Страница 3: ...NCE THAT YOU FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER b To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any e...

Страница 4: ...from electric outlet Never allow the clips of charger to touch each other Clips may be energized and they may spark 5 2 Attach clips to battery and chassis as indicated in sections 6 and 7 6 FOLLOW T...

Страница 5: ...and ordinances The plug pins must fit the receptacle outlet Do not use with an ungrounded system 8 2 DANGER Never alter the AC cord or plug provided if it does not fit the outlet have a proper ground...

Страница 6: ...the vehicle s accessories 2 Keep the hood open 3 Clean the battery terminals 4 Set the switch to the OFF position 5 Lay the AC DC cables away from any fan blades belts pulleys and other moving parts t...

Страница 7: ...atic Charge is performed the charger switches to the maintain mode automatically after the battery is charged ABORTED CHARGE If charging cannot be completed normally charging will abort When charging...

Страница 8: ...k power cord and extension cord for loose fitting plug Have the battery checked The Boost Charging LED is flashing The charger has stopped in Boost or Charge mode The battery is bad The charger cannot...

Страница 9: ...presentatives in order for repair or replacement to occur Manufacturer does not provide any warranty for any accessories used with this product that are not manufactured by Schumacher Electric Corpora...

Страница 10: ...senchufe el cargador del tomacorriente antes de intentar llevar a cabo cualquier actividad de mantenimiento o limpieza El simple apagado de los controles no reducir este riesgo 1 11 ADVERTENCIA RIESGO...

Страница 11: ...ater as que no cuentan con tapas extra bles para pilas tales como bater as de plomo cido reguladas por v lvulas VRLA por sus siglas en ingl s siga cuidadosamente las instrucciones de recarga del fabri...

Страница 12: ...eh culo o al bloque motor alejado de la bater a No conecte al carburador l neas de combustible o cuerpos met licos Conecte a una pieza met lica de calibre grueso del marco o del bloque motor 6 7 Al de...

Страница 13: ...del cargador Aseg rese de que el cable de extensi n est conectado correctamente y en buenas condiciones el ctricas El tama o del cable debe ser lo suficientemente extenso para el calibre de amperios...

Страница 14: ...que los cables de CA CC lejos de las aspas del ventilador bandas poleas y otras partes m viles que pueden causar lesiones 6 Conectar la bater a seg n las instrucciones que indicadas en las secciones 6...

Страница 15: ...gador cambia del maintain mode modo de mantenimiento autom ticamente despu s que la bater a se cargue CARGA ANULADA Si no se puede completar la carga normalmente la carga se anular Cuando la carga se...

Страница 16: ...sujeta a los cables 13 LOCALIZACI N Y RESOLUCI N DE PROBLEMAS PROBLEMA CAUSA POSIBLE SOLUCI N El cargador no se enciende incluso al estar bien conectado Tomacorriente de CA fuera de funcionamiento Co...

Страница 17: ...un momento y pruebe nuevamente En una bater a muy descargada utilice el tipo de Boost 40A durante 10 a 15 minutos para ayudar a ayudar en el arranque 14 ANTES DE DEVOLVER A REPARACIONES Si estas solu...

Страница 18: ...nas que nos sean el Fabricante o si esta unidad es revendida a trav s de un vendedor minorista no autorizado El Fabricante no realiza ninguna otra garant a incluidas a t tulo enunciativo las garant as...

Страница 19: ...e Purchased____________________ Date of Purchase__________ Store Location_____________________ UPC Number_________________________ Serial Number_______________________________________ SEE PRODUCT For...

Отзывы: