Instructions for use.
fridolin 1. & fridolin 2.
The functional sub-frames for
indoor areas.
Страница 1: ...Instructions for use fridolin 1 fridolin 2 The functional sub frames for indoor areas fridolin 1 fridolin 2 ...
Страница 2: ...s for use carefully prior to initial commissioning of the product and to observe them Please note that guidelines and representations in these Instructions for use may deviate from your product due to differing equipment We reserve the right to make technical modifications Important information Ensure that these Instructions for use remain with the product Your schuchmann Team ...
Страница 3: ...model equipment 07 2 6 List of accessories 07 2 7 Product overview 08 3 Settings 09 3 1 Locking unlocking the castors 09 3 2 Seat height 09 3 3 Seat angle adjustment 10 3 4 Adaptation of seat pans 11 3 5 Central locking brake 12 3 6 Foot support 12 3 7 Push bar handling 12 3 8 Handling push handle 13 3 9 Wheel base extension 13 4 Cleaning and maintaining 14 4 1 Cleaning and disinfecting 14 4 1 1 C...
Страница 4: ...Identification 19 7 1 EU Declaration of Conformity 19 7 2 Serial number date of manufacture 20 7 3 Product version 20 7 4 Issue of the document 20 7 5 Name and address of the manufacturer specialist dealer supplying the product 20 ...
Страница 5: ...otect the environment to prevent environmental pollution and to improve the recycling of raw materials please note the disposal instructions in points 1 3 1 and 1 3 2 1 3 1 Packaging The packaging of the product should be kept for any future transport that might be required Should you have to return the product for repairs or in case of a guarantee claim please if possible use the original box so ...
Страница 6: ... according to the intended purpose The fridolin 1 and fridolin 2 indoor sub frames are medical products of risk class 1 and are suited exclusively for indoors use The sub frames are designed as substructure to accommodate seating systems and seat pans Any other use or use over and above this purpose shall be conside red not in accordance with the intended purpose 2 3 1 Indication The indication fo...
Страница 7: ...b frame if all components have been correctly mounted and adjusted Please read out the Instructions for use for users suffering from a visual or reading impairment so that they can use the sub frame safely 2 5 Basic model equipment Tilt adjustment of the seat unit via gas pressure spring 500N Mechanical height adjustment for fridolin 1 Height adjustment by means of gas pressure spring for fridolin...
Страница 8: ...he most important components as well as the terms which you will find in these Instructions for use fridolin 1 fridolin 2 Support head Hand trigger for seat angle adjustment Uprights Castors Trapezoidal adapter Hand trigger for seat angle adjustment Central column Castors Foot pedal for height adjustment ...
Страница 9: ...A 3 2 Seat height fridolin 1 To adjust the seat height undo the screws of the clamps B on the uprights and put the seat pan into the desired position The height of the gas pressure spring must then be adjusted To this end undo the two screws C in the centre between the two uprights and adjust the gas pressure spring to the required height Firmly tighten all screws again If the seat height is adjus...
Страница 10: ...he right as far as it will go and then release it again Now the foot pedal is secured against in advertent operation The locking mechanism is released by pulling on the knurled knob B and turning it to the right For safety reasons the adjustment may only take place when no one is on the product 3 3 Seat angle adjustment In order to adjust the angle of the seat unit the hand trigger C at the rear b...
Страница 11: ...pulling the button Tilt the pan slightly and remove it Ensure that the patented closure is correctly engaged and that the knurled knob is firmly tightened so that it can no longer be pulled Seat pan adapter trapezoidal shape Place the seat pan with the trapezoi dal shaped mounted adapter piece on the trapezoidal shaped seat pan adapter plate and push back Here the patented closure engages au tomat...
Страница 12: ...t has been plugged into the support head B and after the depth has been adjusted the knee angle can be adjusted using the two clamping levers C 3 7 Push bar handling Thepushbarmakesiteasiertorelocate the room frame and can be adjusted in depth and angle The angle is ad justed by releasing the quick release clamp D on both sides Then bring the push bar into the correct position and tighten the quic...
Страница 13: ...e levers B Release them to adjust the correct position and then tighten the lever firmly again Only use the push handle to push the sub frame Do not hang objects onto the push handle Increased risk of tipping 3 9 Wheel base extension The wheel base extension is used to keep the product steady in particular with larger seat pans and seat angles tilted far to the rear The wheel base extension 10 cm ...
Страница 14: ...and evenly applied with a soft cloth Alternatively wipes pre soaked with disinfectant can be used to wipe the products over the entire surface In both cases care must be taken to ensure complete wetting Disinfection in fully automatic disinfection systems is also possible and recommended The exposure times may vary and can be found in the manufacturer s ins tructions for the products used 4 2 Serv...
Страница 15: ...onality of other adjustment elements push bar and footrests Functionality of the gas pressure springs if necessary readjustment of thebowden cables Functionality of the safety elements anti tilt Functionality of brakes Functionality of the rollers concentricity smooth running Legibility of the type label Final complete functional check of the aid Check that all mounting parts and associated access...
Страница 16: ...if the usage takes place in accordance with the information in these Instructions for use It may be possible to use the product over and above this time period if it is in a safe condition The expected duration of use does not refer to wear parts such as for example covers wheels batteries The maintenance and evalua tion of the condition and if applicable the potential for re use must be decided b...
Страница 17: ...otal width 43 cm 51 cm max load 50 kg 50 kg Weight 7 kg 8 kg A D C B A D C B Size 1 Size 2 A Height of seat pan support 41 53 cm 41 53 cm B Seat angle 5 35 5 35 C Total length 66 cm 77 cm D Total width 45 cm 53 cm Thickness of the gas pressure spring for tilt adjustment 250 N 350 N max load 50 kg 50 kg Weight 7 kg 8 kg 5 2 Dimensions fridolin 2 A D C B A D C B ...
Страница 18: ...ts This begins with the delivery or handover of the goods Should a verifiable material or manufacturing fault occur within this time period we shall after carriage paid return to us view the indicated damage and if applicable either repair or deliver a new product at our discretion ...
Страница 19: ...aufgeführten Richtlinien und Standards entspricht is are in conformity with the requirements of the below listed directives and standards Verordnung EU 2017 745 über Medizinprodukte vom 05 April 2017 Regulation EU 2017 745 on medical devices of 5 April 2017 DIN EN 12182 2012 Technische Hilfen für behinderte Menschen Technical aids for disabled persons DIN EN ISO 14971 2013 Medizinprodukte Anwendun...
Страница 20: ...of the manufacturer specialist dealer supplying the product This product was manufactured by 7 Identification This product has been delivered by the following specialist dealer Schuchmann GmbH Co KG Rudolf Runge Str 3 49143 Bissendorf Germany Phone 49 0 5402 40 71 00 Fax 49 0 5402 40 71 109 info schuchmann de www schuchmann de A Product name Item number Serial number schuchmann de info schuchmann ...