3. 

 Die hardwaremäßige Verkabelung durchführen. Minimal 

erforderlich sind der Anschluss

 

der 12-24V DC Versorgung 

und der GSM-Antenne. Ein Beispiel zur Beschaltung:

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
4.

  Externe  Spannungsversorgung  einschalten.  Die  gelbe  LED 

sollte  zunächst  jede  Sekunde  blinken  (das  Modem  loggt  sich 
beim  Provider  ein).  Sobald  das  Modem  im  GSM-Netz 
registriert  ist,  blinkt  die  gelbe  LED  alle 3 Sekunden kurz. Die 
rote  LED  zeigt  eine  Aktivität  an,  sie  blinkt  wenn  ein  SMS 
versandt oder gelesen wird.  
 

ACHTUNG:  Sollten  Sie  zum  Testen  eine  SIM-Karte 
verwenden,  auf  der  viele SMS gespeichert sind, dann 
liest das Gerät nach dem Einschalten alle SMS aus und 
löscht  diese  (=  die  rote  LED  blinkt  die  ganze  Zeit). 
Erst  nach  Abarbeiten  dieser  SMS  ist  das  Gerät  bereit 
neue SMS zu empfangen oder zu senden!

 

 

5.

  Das  Gerät  ist  betriebsbereit  und  muss  nur  noch 

parametrisiert werden. 

 

 

C. GRUNDSÄTZLICHE FUNKTIONSWEISE:  

 

Sobald das Gerät im GSM-Netz eingeloggt ist, schickt es zum 
Selbsttest ein SMS an sich selbst und liest daraus auch gleich 
das  aktuelle  Datum  und  die  Uhrzeit.  (ACHTUNG:  Das 
funktioniert nur, wenn wie in Punkt D beschrieben die eigene 
SIM-Nummer eingetragen wurde!) 
 
Das  Gerät  besitzt  4  digitale  Eingänge.  Jeder  dieser  Eingänge 
löst  genau  eine  Meldung  aus  –  die  per  SMS  und  Email 
geschickt wird – sobald Spannung an diesem Eingang anliegt. 

Bei  den  Eingängen  1  bis  3  muss  mindestens  60 
Sekunden  lang  permanent 

Spannung  anliegen,  um  den 

Versand  der  Meldung  auszulösen.  Der  Eingang  4  löst  schon 
nach  1  Sekunde  die  Meldung  aus  -  er  ist  für 

3.

 Do the hardware wiring. It is necessary at least to connect 

the 24V DC power supply and the GSM-antenna. See also the 
following example for external wiring:

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
4.

 Activate the external power supply system. The yellow LED 

should be blinking every second (the modem dials in). As soon 
as the modem will be registered in the providers network, the 
yellow  LED  is  shortly  blinking  every  3  seconds.  The  red  LED 
always  indicates  an  activity  -  it  starts  blinking  when  a  SMS  is 
been sent or read.  
 

WARNING: Do better not use a SIM card with lots of 
stored SMS! The device reads out all of the SMS and 
afterwards deletes them (= the red LED is 
permanently blinking). Then the device is able to send 
and read new SMS. 
 
 
5.

 The Communication Center is now ready for use; you have 

to set the parameters only. 

 

   C. BASIC INFORMATION

 

 

After  the  Communication  Center  is  registered  in  providers 
network  the  internal  selftest  starts  by  sending  a  SMS  to  its 
telephone  number.  When  the  CC  receives  the  SMS  it  checks 
the  actual  date  and  time  (this  will  work  only  if  the  telephone 
number is entered in the parameters – see D.). 
 
The device contains 4 digital inputs. Each of these inputs can 
trigger  one  message  that  will  be  sent  by  SMS  or  Email,  as 
soon as the input detects an external voltage. Input number 1 
to 3 needs to detect external voltage at minimum 60 seconds 
continuously  to  trigger  a  message.  Only  input  number  4 
triggers  a  message  after  1  second  detecting  an  external 
voltage – it’s ideal for motion detectors or other short signals. 
After  triggering  a  message  the  input  has  to  be  low  (without 

12-24VDC

GND

L1
N

Verbraucher
max. 5A/250VAC

potentialfreier 
Kontakt,
max. 24VDC

Содержание COMMUNICATION CENTER II BZ990001

Страница 1: ...ei dieser Gelegenheit kann auch berpr ft werden ob das GSM Netz am Standort stark genug ist mindestens 3 von 5 Strichen auf der Anzeige je nach Typ des Mobiltelefons 2 Die beiden Seitenlaschen des CC...

Страница 2: ...3 muss mindestens 60 Sekunden lang permanent Spannung anliegen um den Versand der Meldung auszul sen Der Eingang 4 l st schon nach 1 Sekunde die Meldung aus er ist f r 3 Do the hardware wiring It is...

Страница 3: ...612345678 max provider at Die Eingestellten Nummern k nnen jederzeit durch folgendes SMS abgefragt werden Nr D1 4 OPTIONAL Falls die 2 Ausg nge ben tigt werden m ssen ihnen Namen zugewiesen werden das...

Страница 4: ...om GSM Provider und Feiertagen k nnen zum Teil erhebliche Verz gerungen bei der bermittlung von SMS entstehen Generell wird vom Provider keine Garantie auf eine fehlerfreie und zeitlich bestimmte Verm...

Страница 5: ...ie Zust nde der Eing nge und damit auch der Z hler st nde k nnen zyklisch t glich w chentlich monatlich per E mail an die eingestellt Mailadresse gemeldet werden Der Versand erfolgt automatisch um 9 3...

Страница 6: ...ndardgateway Falls danach im Browser bei Eingabe von http 192 168 1 103 keine Eingabe erscheint muss der Proxyserver ausgeschatet werden Dazu Bsp Internet Explorer auf Extras und Internetoptionen klic...

Страница 7: ...nganges weggel scht dann wird dieser deaktiviert und auch in der Zustandsanzeige und der Datenaufzeichnung nicht angezeigt Auch den Ausg ngen k nnen in der Subseite Einstellung der Ausg nge Namen zuge...

Страница 8: ...peichert Die Spalte Meldung gibt an aus welchem Grund die Aufzeichnung erfolgte 0 ein Ausgang wurde geschalten 1 der Eingang 1 hat eine Meldung ausgel st 4 der Eingang 4 hat eine Meldung ausgel st 5 d...

Отзывы: