![SCHOLTES TT 6044 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/scholtes/tt-6044/tt-6044_operating-instructions-manual_1214018015.webp)
GB
15
UNDERSIDE OF HOB
The thickness of the supporting surface should be taken
into account when choosing screws for the fixing hooks:
30 mm thick: 17.55 mm screws
40 mm thick: 7.55 mm screws
Fix the hob as follows:
1. Use short flat-bottomed screws to fix the 4 alignment
springs in the holes provided in the centre of each side
of the hob.
2. Insert the hob in the cavity, make sure it is in a central
position and push down on the whole perimeter until the
hob is stuck to the supporting surface.
3. For hobs with raised sides: After inserting the hob into
its cavity, insert the 4 fixing hooks (each has its own pin)
into the lower edges of the hob, using the long pointed
screws to fix it in place, until the glass is stuck to the
supporting surface.
The screws for the alignment springs must remain
accessible.
In order to adhere to safety standards, the appliance
must not come into contact with electrical parts once it
has been installed.
All parts that ensure the safe operation of the appliance
must not be removable without the aid of a tool.
Electrical connection
The electrical connection of the hob and any built-in
oven must be carried out separately, both for safety
purposes and to make extracting the oven easier.
Terminal board
On the lower part of the
appliance there is a connection
box for the different types of
electricity supply (the picture is
only an indication and is not an
exact representation of the
purchased model).
Single-phase connection
The hob is equipped with a preconnected electricity
supply cable, which is designed for single-phase
connection. Connect the wires according to the
instructions given in the following table and diagrams:
Voltage and
mains frequency
Electrical cable
Wire connection
230V 1+N ~
50 Hz
: yellow/green;
N: the two blue wires
together
L: brown and black
together
Other types of connection
If the mains supply corresponds with one of the
following:
Voltage and mains frequency
400V - 2+N ~ 50 Hz
230V 3 ~ 50 Hz
400V - 2+2N ~ 50 Hz
Separate the wires and connect them according to the
instructions given in the following table and diagrams:
Voltage and
mains frequency
Electrical cable
Wire connection
400V - 2+N ~
50 Hz
230V 3 ~
50Hz
: yellow/green;
N: the two blue wires together
L1: black
L2: brown
400V - 2+2N ~
50 Hz
: yellow/green;
N1: blue
N2: blue
L1: black
L2: brown
If the mains supply corresponds with one of the
following:
Voltage and mains frequency
400V 3 - N ~ 50 Hz
proceed as follows:
The cable provided is not suitable for the following
types of installation.
1. Use a suitable supply cable, H05RR-F or higher, with
the right dimensions (cable section: 2.5 mm).
2. To open the terminal board, insert a screwdriver into
the side tabs of the cover and open it (
see Terminal
board picture
).
3. Loosen the cable clamp screw and the terminal board
screws according to the type of connection required and
position the connection supports as shown in the
following table and diagrams.
4. Position the wires according to the following table and
diagrams and connect the appliance by tightening all
the screws for the springs as much as possible.
Voltage and
mains frequency
Electrical connections
Terminal board
400V 3-N ~ • 50
Hz
Three-phase 400
5. Secure the power supply cable by fastening the cable
clamp screw, then put the cover back on.