background image

GBA C 6001 12 E 

 

BA 

Page 5 of 26 

Mai 5, 2021 

Last revised 05-2021 

 

Rev. 12 

S

ch

o

ll

 A

p

p

ar

at

eb

au

 G

m

b

H

 &

 C

o

KG

 

 

 

G

ENERAL

 

1.1  I

NFORMATION ABOUT THE USER MANUAL

 

This user manual describes the installation, operation and maintenance of the device and serves as an im-
portant source of information and reference. 

The knowledge of all safety and handling instructions contained in the user manual creates the conditions 
for the safe and proper operation of this device. 

In addition, you must comply with all relevant local accident prevention regulations and safety regulations 
concerning the permitted uses of the device. 

The user manual is part of the product and must be accessible at all times in the immediate vicinity of the 
device for the installation, operation, maintenance and cleaning staff. 

 

1.2  L

IABILITY AND WARRANTY

 

All information and instructions in this user manual have been compiled in accordance with cur-rent regula-
tions, the current state of engineering technology and our many years of knowledge and experience. 

The actual scope of delivery may differ for special designs, utilization of additional order options or due to 
the latest technical changes to the explanations and representations described herein. In case of questions, 
please contact the manufacturer. 

   NOTE! 

This user manual should be read carefully before starting work on and with the device, in particular be-
fore commissioning! The manufacturer accepts no liability for damage and faults that arise from non-
compliance with the operating instructions. 

The user manual must be kept directly on the device and accessible to all persons working on or with the 
device. We reserve the right to make technical changes to the product in the context of improving the us-
age properties and further development. 

 

Содержание C 6001

Страница 1: ...001 CPZ 330 C 6003 CPA 330 W C 6106 CP 330 RAL C 6002 CPZ 330 RAL C 6004 CPA 330 SI C 6107 CP 660 C 6005 CPZ 660 C 6007 CPA 330 S C 6108 CP 660 RAL C 6006 CPZ 660 RAL C 6008 CPA 660 W C 6109 CP 990 C...

Страница 2: ...7 2 3 Intended use 8 3 Transport packaging and storage 9 3 1 Transport inspection 9 3 2 Packaging 9 3 3 Storage 9 4 Technical data 10 4 1 Technical specifications 10 4 1 1 Built in hot or cold combipl...

Страница 3: ...ical connections 17 5 3 Operation 17 5 3 1 Control panel 18 6 Cleaning and maintenance 19 6 1 Safety instructions for cleaning 19 6 2 Cleaning 19 6 3 Safety instructions for maintenance 20 6 4 Mainten...

Страница 4: ...lly before starting up this appliance On the following pages you will find important notes regarding its operation care and maintenance so that you will be able to enjoy its use for a long time If a m...

Страница 5: ...1 2 LIABILITY AND WARRANTY All information and instructions in this user manual have been compiled in accordance with cur rent regula tions the current state of engineering technology and our many ye...

Страница 6: ...erpts as well as the utilization and or communication of the content is forbidden without permission in writing from the manufacturer Any non compliance is liable for damages All other rights are rese...

Страница 7: ...egarding operational safety are based on the regulations of the European Union valid at the time of manufacturing of the device If the device is used commercially the operator is obliged during the en...

Страница 8: ...intenance are to be made by qualified service personnel The hot or cold combiplate is for keeping dishes warm or cool not for warming or cooling of prepared dishes ATTENTION Any and all use diverting...

Страница 9: ...kaging of your device It might be useful for storage purposes when moving or if the device needs to be sent to our service centre in case of damage The outer and inner pack aging material has to be re...

Страница 10: ...oise level 49 9 dBA 59 3 dBA 59 3 dBA Condensing temperature 12 1 C 12 1 C 12 1 C Power requirement 230 V 50 60 Hz ready to plug in connection cable with Schuko plug 1 6 m Separate control panel 120 x...

Страница 11: ...50 100 W 1520 100 W 2340 100 W Power requirement 230 V 50 60 Hz ready to plug in connection cable with Schuko plug 1 6 m Separate control panel 120 x 55 x 42 mm controller with cable length 1 2 m Dime...

Страница 12: ...330 x 530mm 660 x 530mm 660 x 530mm Temperature range 5 C to 140 C continuously variable Amount refrigerant 38 g 38 g 38 g 39 g 39 g Refrigerant R600a R600a R600a R600a R600a Heating capacity cooling...

Страница 13: ...i 5 2021 Last revised 05 2021 Rev 12 Scholl Apparatebau GmbH Co KG 4 2 PRODUCT DIAGRAM 4 2 1 BUILT IN HOT OR COLD COMBIPLATE Figure size 1 x 1 1 GN 4 2 2 BUILT IN HOT OR COLD COMBIPLATE FOR CENTRAL CO...

Страница 14: ...GBA C 6001 12 E BA Page 14 of 26 Mai 5 2021 Last revised 05 2021 Rev 12 Scholl Apparatebau GmbH Co KG 4 2 3 TABLE TOP HOT OR COLD COMBIPLATE Figure size 1 x 1 1 GN...

Страница 15: ...g operation some parts of the device become very hot To avoid burns do not touch hot parts Do not use this device if it is not working properly is damaged or has been dropped Do not use any accessorie...

Страница 16: ...le in the accessories and remove the excess silicone After a drying time of 24 hrs you can connect the hot or cold combiplate to the power supply and start to operate NOTE regarding the installation T...

Страница 17: ...r the following devices C 6001 C 6002 C 6005 C 6006 C 6009 C 6010 5 3 OPERATION Clean the device prior to use as described in chapter 6 2 Cleaning Press the button to switch on the device Do not place...

Страница 18: ...ng the button the adjusted tempera ture will be shown in the display To change the temperature press and either or to adjust the temperature accordingly Selection button The button is used to switch b...

Страница 19: ...th a water jet Therefore do not use a pressure water jet to clean the device 6 2 CLEANING Clean the device regularly with a neutral cleaning agent Before cleaning the device switch it off with the but...

Страница 20: ...tenance and repair work may only be performed by qualified professionals using original spare parts and accessories Never try to carry out repairs to the device yourself 6 4 MAINTENANCE Check in regul...

Страница 21: ...pply Contact the seller Contact the seller Bad cooling Evaporator dirty Fan dirty Overheating on installation site Cleaning by service engineer Cleaning by service engineer Check supply and exhaust ai...

Страница 22: ...advisable to contact a specialised waste management company or to contact the local disposal service in your community WARNING To avoid misuse and the associated dangers make sure the old device is un...

Страница 23: ...23 of 26 Mai 5 2021 Last revised 05 2021 Rev 12 Scholl Apparatebau GmbH Co KG 9 INSTALLATION DRAWINGS Dimensioned drawings are available upon request 9 1 TEMPERATURE CONTROLLER HOT OR COLD COMBIPLATE...

Страница 24: ...GBA C 6001 12 E BA Page 24 of 26 Mai 5 2021 Last revised 05 2021 Rev 12 Scholl Apparatebau GmbH Co KG 10 CIRCUIT DIAGRAMS Circuit diagrams are available upon request...

Страница 25: ...will be accepted Further warranty information is contained in our Gen eral Terms and Conditions of Sale or can be made available upon request Appliances not produced by ourselves are subject to the w...

Страница 26: ...he following times Monday Thursday from 7 00 a m till 4 00 p m Fridays from 7 00 a m till 12 15 p m Outside these office hours please communicate your requests per e mail or telefax Scholl Apparatebau...

Страница 27: ......