• Make sure that the induction unit does not take in hot ambient air (concerns units standing side by
side, or one behind the other, or standing near a frying pan or an oven), otherwise an air duct incl.
shackle has to be added.
• The induction unit must not be placed next to an oven or another heat producing unit.
• The air intake temperature must not exceed 40°C.
• The operating staff has to make sure that installation, support and inspection is done by qualified
personnel.
3.4 I
NSTALLATION CLIPPING MODEL
BH/HO/IN
1800
Advice for installation heat retention plate:
As soon as the mounting devices according to the above-mentioned steps are finished, you may continue
with installation. Put the heat retention plate with coil and ceran surface into the clipping. Install the
mounting construction on the working area and seal it with Pactan. The connecting cables have a length of
2.5m. The connecting cable must be laid and must not be rolled up.