KLG / KNG / SNG / RNG / PNG
II/9
GB
*For troubleshooting: refer to the information in the "Technical data" chapter in part 1 of the instruction manual!
**See Chapter: "Intended use" in Instruction manual part 1!
***For troubleshooting: read chapter: "Commissioning"!
****For troubleshooting: read chapter: "Maintenance"!
If necessary, contact our service staff, see last page.
C Staples / Nails are
not fully inserted,
bend or protrude
Tappet worn or broken
Contact Schneider Druckluft GmbH or an
authorised service partner.
****
Working pressure (flow
pressure) too low
Increase working pressure (flow pressure)
Observe maximum working pressure
*
Compressor output too
small
Use different output
rating
*
Hose diameter too
small
Use correct hose diameter
*
D Tool repeatedly
misfires
Piston sluggish because
lubrication insufficient
Lubricate device well via plug nipple
(item 01)
***
Working pressure (flow
pressure) too low
Increase working pressure (flow pressure)
Observe maximum working pressure
*
O-ring damaged
Contact Schneider Druckluft GmbH or an
authorised service partner.
****
Hose diameter too
small
Use correct hose diameter
*
Insertion depth setting
incorrect (if available)
Check and adjust insertion depth setting.
E Staples / Nails
jammed in the
guide plate
Magazine (item 04)
dirty
Clean magazine
(blow out)
****
Staple / Nail strip
jammed and/or not
pushed all the way for-
wards
Incorrect staples / nails used. Insert the
correct staples / nails
*
Tappet worn
Contact Schneider Druckluft GmbH or an
authorised service partner.
****
Staple/Nail jammed
Unlock the quick-release cover (item 12)
(if available) via the magazine and re-
move the staple or nail.
F No staples / nails
are transported
No staples / nails in the
magazine
Insert the correct staples / nails
****
Tappet does not retract
Increase working pressure (flow pressure)
Observe maximum working pressure
*
or contact Schneider Druckluft GmbH or
an authorised service partner.
****
Staple / Nail slider
faulty
Contact Schneider Druckluft GmbH or an
authorised service partner.
****
Magazine spring faulty
Change magazine spring or
Contact Schneider Druckluft GmbH or an
authorised service partner.
****
Problem
Cause
Remedy