II/8
PEM
GB
• Be calm and focused and ensure proper
operation.
• Protect yourself and other persons, ani-
mals, property, and the environment by
taking the necessary protective measures
and being trained in use of the devices to
prevent harm to your health, property
damage, financial loss, environmental
harm or risk of accident.
• Repairs may be carried out only by
Schneider Druckluft GmbH or its approved
service partners.
• Observe the Instruction Manual for ves-
sels!
•
Prohibited:
Manipulations, use for pur-
posed other than those intended; tempo-
rary repairs; compressing other energy
sources; removing or damaging safety
equipment; use in case of leaks or mal-
functions; not using original spare parts;
exceeding the specified permitted final
compression pressure; working without
safety equipment; transporting the unit,
maintaining it, repairing it or leaving it un-
supervised while pressurised; using other/
incorrect lubricants; smoking; open flame;
removing stickers.
•
Prohibited:
filling the fuel tank while the
engine is running, adjusting the idle speed
control.
2.4 Commissioning
2.4.1 Transport
• Check the handle for secure fit.
• Vessel depressurised.
• In the vehicle: transport the compressor in
an upright position, secure and protect it.
2.4.2 Conditions at the installation lo-
cation
• Rooms: as dust-free as possible, dry, well
ventilated.
• Installation surface: flat, horizontal.
2.4.3 Before first use
1. Carry out a visual inspection.
2. Check the electrical connection.
3. Check the oil level (see Chap. 2.6.6).
L
For units with attached oil dipstick, re-
place with sealing plug in unit and fill with
oil.
2.4.4 Filling the mist oiler
For compressors with mist oiler:
1. Depressurise the compressor/vessel.
2. Unscrew the oil tank from the mist oiler.
(Figure 3a)
Use suitable oil (Art. No. B770000)!
2.4.5 Adjusting the mist oiler
1. Carefully screw the regulating screw
closed using a screwdriver in a clockwise
direction. The screw it open by 1/2 to 1
turn (Figure 3a).
2. During air extraction, oil deposits in the
form of droplets can be seen at the upper
sight glass.
Dosing: 1 droplet oil at 300 – 600 l/min
air consumption. Readjust If necessary
and check regularly.
Important:
Use separate air hoses oiled air
≤
10 m. Observe the Instruction Manual for
"Compressed air tools"!
2.5 Operation
2.5.1 Use
1. Check the fuel and oil level in the petrol
engine.
2. Depressurise the vessel.
3. Connect the compressed air hose to the
quick-action coupling of the compressor.
It is locked automatically.
4. Connect the consumer.
5. Start the petrol engine to start up the
compressor (see petrol engine instruc-
tion manual).
The compressor fills the vessel and then
switches to idle mode: the compressor is
ready for use.
2.5.2 Adjusting the working pressure
1. Pull up the adjustment button on the (fil-
ter) pressure reducer (Figure 4a).
2. Rotate clockwise = pressure is in-
creased. Rotate anticlockwise = pressure
is reduced.
3. Read the set working pressure on the
pressure gauge (item 13).
WARNING
Hearing damage from noise during op-
eration!
X
Wear ear protection!
WARNING
Risk of poisoning from exhaust fumes!
X
Do not use inside closed rooms!