![SCHMITT MPN Series Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/schmitt/mpn-series/mpn-series_original-operating-manual_1213682022.webp)
Maintenance
13. Screw in the hexagon socket screw (09) and secure the
external magnet (07).
14. Check the correct installation dimension
B
.
15. Insert the unit of the rear cover (05) together with the
impeller (04) into the external magnet (07).
16. Assemble the housing (36) on to the rear cover (05) and the
impeller (04). When doing so, make sure that the ring (13v)
is seated correctly on the angle ring (12v).
17. Using the hex-head bolts (27-3),
washers (42-3)
and hexagon nuts (43), attach the housing (36) to
the pump support (01).
When doing so, tighten
the nuts across diagonals and to the correct torque
9.2.5 Tightening torques of casing screws, Page 29).
18. Spin the motor fan impeller and make sure that the
impeller (04) runs freely in the plain bearings.
7.5.3
Install the pump into the system
Install the pump in the system.
22
MPN
11333/0519