Instructions for Use
– SCHMIDT
®
Flow Sensor SS 20.700
Page 33
10 Technical data
Measurement-specific data
Measuring values
Standard velocity w
N
of air, based on standard condi-
tions of 20 °C and 1,013.25 hPa
Temperature of medium T
M
Medium to be measured
Standard: Air or nitrogen
Optional: Natural gas, biogas, CO
2
and special gases
or gas mixtures
Measuring range w
N
Standard: 0 ... 10 / 20 / 60 / 90 / 140 / 220 m/s
Special:
10
… 220 m/s (steps: 1 m/s)
Lower detection limit w
N
0.1 m/s
Measuring range T
M
-20 ...+120 °C
Measuring accuracy
26
Standard w
N
±3 % o. m. v. + (0.4 % o. f. v.; min. 0.08 m/s)
27
Response time (t
90
) w
N
10 s (jump of w
N
from 0 to 5 m/s in air)
Temperature gradient w
N
< 8 K/min (at w
N
= 5 m/s)
Measuring accuracy
28
T
M
±1 K (10 ... 30 °C)
±2 K remaining measuring range
Operating temperature
Sensor probe
-20
… +120 °C
Electronics
-
20 … +70 °C
Storage temperature
-
20 … +85 °C
Material
Enclosure
Anodized aluminum
Sensor tube
Stainless steel 1.4571
Compression fitting
Stainless steel 1.4571, NBR (or FKM)
Sensor head
Stainless steel 1.4404
Sensor cable (remote sensor)
Sheathing TPE, halogen-free
26
Under reference conditions
27
„o. m. v.“: of measured value; „o. f. v.“: of final value
28
(w
N
> 2 m/s)