Instructions for Use SS 20.60
Page 9/16
ATTENTION
The stop face of the housing must
not
be used
for securing.
The housing
must not
be turned any more,
once the through bolt joint has been tightened.
Otherwise, the housing may be detached from
the sensor tube
.
6 Electrical connections
1
4
3
2
bn
sw
bl
+ 24 VDC
Signal
GND
ws
Digital
Figure 3: SS 20.60 connection assignment (view of the plug pins at
the sensor)
The cable supplied has the following color assignment:
ws = white, bn = brown, sw = black, bl = blue
The negative of the dc voltage (GND) is at the same time the
reference potential for the analog signal.
ATTENTION
Only operate the sensor in the defined range of
operating voltage (24 VDC +/- 20 %).
Undervoltage
may
result
in
malfunction.
Overvoltage may lead to irreversible damage to
the sensor.