Instructions for Use SS 20.261
Page 10
Mounting
The sensor is installed using its integrated compression fitting. Normally,
a sleeve is welded as a connecting piece onto a bore in the medium-
guiding pipe, in which the external thread (G½) of the compression fitting
is screwed (see Figure 3).
L
AL
66
SL
32
MET=20
8
E
D
A
Figure 3
L
Probe length [mm]
SL
Length of weld-in sleeve [mm]
AL
Projecting length [mm]
D
A
Outer diameter of pipe [mm]
MID
Minimum immersion depth [mm]
E
Setting length of probe [mm]
!
Before mounting depressurize system with overpressure media.
Bore a mounting opening in a pipe wall.
Weld connecting piece with an internal thread G½ in the center
above the mounting opening on the pipe.
Recommended length of connecting piece: 15 ... 40 mm
Slacken compression fitting nut (SW17) to such an extent that
sensor probe can be moved without jamming.
Wrap thread using a common sealing tape, for example made of
PTFE.
Remove protective cap from sensor tip and push compression fitting
up to the dead end of the sensor head.
MID = 20