background image

Edition 

Trum 01.5.E

Instruction Manual

Valid as of: 01.03.2012

 

• Please keep the manual for future reference!

S C H M I D T

c o n t r o l i n s t r u m e n t s

Trummeter 

 

 

Model RTM-400

Содержание RTM-400

Страница 1: ...Edition Trum 01 5 E Instruction Manual Valid as of 01 03 2012 Please keep the manual for future reference S C H M I D T c o n t r o l i n s t r u m e n t s Trummeter Model RTM 400...

Страница 2: ...ation 4 2 General Information 5 2 1 Specifications 5 2 2 Delivery Includes 5 2 3 Unpacking 5 3 Initial Setup and Operating Procedure 6 3 1 Notes Before Starting Measurement 6 3 2 Battery Insertion and...

Страница 3: ...f the device Insufficient inspection of device components that are subject to wear Opening the device or improper repair work Disasters caused by the effects of foreign objects or by force majeure 1 1...

Страница 4: ...d use also includes Complying with all notices included in the Operating Instructions and observing all inspection and maintenance works 1 8 Copyright The copyright on these Operating Instructions rem...

Страница 5: ...ing Temperature 10 to 50 C Transport Temperature 5 to 70 C Display 2 line LCD 16 char line with background lighting Language Selection 10 languages German English Italian French Spanish Portuguese Swe...

Страница 6: ...E block into the BATTERY COMPARTMENT Please ensure proper polarity Close the BATTERY COMPARTMENT 3 2 Battery Insertion and Replacement 3 2 1 Switch On Press the on off key The DISPLAY shows the softw...

Страница 7: ...H ARROW DOWN ENTER ON OFF DISPLAY Displays measured and calculated values in German English Italian French Spanish Portuguese Swedish Norwegian Danish Finnish Measuring probe Measures the natural freq...

Страница 8: ...SI US menu option Set language with ARROW UP DOWN keys and confirm with ENTER Set international or US units of measure SI m kg m N US inch lbs foot Ibf and confirm with ENTER Exit menu menu option Dis...

Страница 9: ...layed in Hz To measure the belt tension Switch on the instrument Set the instrument parameters as described in Chapter 3 4 Menu Structure on page 8 Attention The belt tension can be measured only when...

Страница 10: ...e drive belt are as a rule not caused by a measurement error or fault in the unit In most cases measurement deviations are due to the mechanical tolerances of the drive systems Recommendation Repeat t...

Страница 11: ...improve reflection affix a piece of light colored adhesive tape to the belt or slightly moisten the belt at the measuring point 3 5 3 Measurement Errors In case you have no data from the machine prod...

Страница 12: ...tructions We kindly ask for return free of charge for us if possible by airmail parcel All occurring charges if any such as freight customs clearance duty etc will be billed to customer For return fro...

Отзывы: