Instructions for Use
– SCHMIDT
®
LED Measured Value Display MD 10.015
Page 14
Verification of indication values in display menu (short press of
)
Auxiliary
display
Main
display
Description
.
Main display (standard measurement value):
12.8 m
3
/h
.
Actual measured value of
“Sensor 1”:
12.8 m
3
/h
.
Actual measured value of
“Sensor 2”:
23.9 °C
.
Actual volume quantitiy:
0.2 m
3
Reset to 0 by using
for approx. 5 s
.
Actual raw value
“Sensor 1”:
4.597 mA
.
Actual raw value
“Sensor 2”:
12.179 mA
.
Peak-value memory:
- Maximum measured value of parameter that is selected
for main display:
45.8 m
3
/h
- Deletion of all maximum peak values of sensor by
using
for approx. 5 s
.
Peak-value memory:
- Minimum peak value of parameter that is selected for main
display:
1.8 m
3
/h
- Deletion of all minimum peak values of sensor by
using
for approx. 5 s
.
Switching point of alarm output 1:
150 m
3
/h
Alarm output 2: Deactivated
After the final menu item, the dispaly menu is left automatically for chang-
ing to the main display.