background image

7

2.1.2 Available FSP Models

with RS-232 or USB Interface (Code 232 / USB)

FSP Guide Pins:

2.1.3 Available FSH Models

with RS-232 or USB Interface (Code 232 / USB)

FSH Guide Rollers:

Model with

Tension Range

Tension

Ranges [cN]

*Measuring 

Head Width 

[mm]

**Schmidt

Calibration Material

FSP-50-

0 - 50

64

PA: 0.12 mm Ø

FSP-100-

0 - 100

64

PA: 0.12 mm Ø

FSP-200-

0 - 200

64

PA: 0.12 mm Ø

FSP-500-

0 - 500

64

PA: 0.20 mm Ø

Ceramic Pins

Line Speed 

[m/min ... max.]

Pin Material

Standard

2000

Oxide ceramic 5.2 mm Ø

Model with

Tension Range

Tension

Ranges [cN]

*Measuring Head 

Width [mm]

**Schmidt

Calibration Material

FSH-1000-

0 - 1000

150

PA: 0.30 mm Ø

FSH-2000-

0 - 2000

150

PA: 0.50 mm Ø

FSH-5000-

0 - 5000

150

PA: 0.80 mm Ø

FSH-10K-

0 - 10 daN

200

PA: 1.00 mm Ø

FSH-20K-

0 - 20 daN

240

PA: 1.50 mm Ø

FSH-50K-

0 - 50 daN

240

Steel rope: 1.5mm Ø 

(7 x 7 x 0.20)

*  Outside dimensions of front plate. 
** Suitable for 95% of applications. PA = Polyamide Monofilament 
  Should the process material differ significant from the SCHMIDT calibration material  
  in size, rigidity or shape, we recommend special calibration using customer supplied  
  material. 
  International unit of tensile force: 

1 cN  =  1.02 g  =  0.01 N 

   

1 daN  =  1.02 kg =  10.00 N

V-Groove

Line Speed 

[m/min ... max.]

Roller Material

Standard

4000

Hardened steel

U-Groove 

Code 

R1

4000

Hard chrome-plated steel (radius 5)

flat

Code

 B6

2000

Hardened steel, width 6 mm

Code

 B10

2000

Hardened steel, width 10 mm

Содержание FS Series

Страница 1: ... Series Option RS 232 USB Model FS1 FSP FSH FSW FSL FSB1 Edition FS 232 USB 01 0 E Instruction Manual Valid as of 01 12 2017 Please keep the manual for future reference S C H M I D T c o n t r o l i n s t r u m e n t s ...

Страница 2: ...nnector only Code 232 10 2 4 Optional Accessories 11 2 5 Delivery Includes 11 2 6 Unpacking 11 3 Initial Setup and Operating Procedure 11 3 1 Notes Before Starting Measurement 11 3 2 Mounting possibilities 11 3 3 Connecting the Sensors to a PC 12 3 4 Internal Adjustment of the Sensors 13 3 4 1 ZERO Adjustment 13 3 4 2 GAIN Adjustment 14 4 The TENSION INSPECT 3 Program 15 4 1 System Requirements 15...

Страница 3: ... the device Insufficient inspection of device components that are subject to wear Opening the device or improper repair work Disasters caused by the effects of foreign objects or by force majeure 1 1 Notices within the Operating Instructions The fundamental prerequisite for the safe handling of this device and its troublefree opera tion is the knowledge of the basic safety notices and safety instr...

Страница 4: ...tion will be regarded as misuse Under no circumstances shall HANS SCHMIDT Co GmbH be held liable for damage resulting from misuse The intended use also includes Complying with all notices included in the Operating Instructions and observing all inspection and maintenance works 1 8 Copyright 1 9 Declaration of Conformity RoHs II and WEEE Registration In compliance with the EU Directives 2014 30 EU ...

Страница 5: ...difications customized versions Customized measuring head width Special tension ranges Customized roller dimensions and materials Customized distance between outside guide rollers Special calibration using customer supplied material The Operating Instructions can also be used for these instruments as their handling is the same Model Numbers Model with tension range Code for guide rollers if not st...

Страница 6: ...ted aluminium Code H 5000 Plasma coated aluminium FS1 100 and higher ranges Code T 1000 Plastic POM black Code W 1000 Nickel plated steel Code ST 1000 Hardened steel Code B 1000 Heat treated steel specially for measuring tire cord Code CE2 1000 Aluminium ceramic coated Asymmetrical Groove Code ASY 1000 Hard coated aluminium FS1 500 and higher ranges Code ASYB 1000 Heat treated steel FS1 500 and hi...

Страница 7: ...00 0 1000 150 PA 0 30 mm Ø FSH 2000 0 2000 150 PA 0 50 mm Ø FSH 5000 0 5000 150 PA 0 80 mm Ø FSH 10K 0 10 daN 200 PA 1 00 mm Ø FSH 20K 0 20 daN 240 PA 1 50 mm Ø FSH 50K 0 50 daN 240 Steel rope 1 5mm Ø 7 x 7 x 0 20 Outside dimensions of front plate Suitable for 95 of applications PA Polyamide Monofilament Should the process material differ significant from the SCHMIDT calibration material in size r...

Страница 8: ... the process material differ significant from the SCHMIDT calibration material in size rigidity or shape we recommend special calibration using customer supplied material International unit of tensile force 1 cN 1 02 g 0 01 N 1 daN 1 02 kg 10 00 N 2 1 4 Available FSW Models with RS 232 or USB Interface Code 232 USB FSW Guide Rollers Model with Tension Range Tension Ranges daN Measuring Head Width ...

Страница 9: ...r significant from the SCHMIDT calibration material in size rigidity or shape we recommend special calibration using customer supplied material International unit of tensile force 1 cN 1 02 g 0 01 N 1 daN 1 02 kg 10 00 N Model with Tension Range Tension Ranges cN Measuring Head Width mm Roller Widths mm FSB1 100 0 100 60 7 10 15 20 FSB1 200 0 200 60 7 10 15 20 FSB1 500 0 500 60 7 10 15 20 FSB1 100...

Страница 10: ...ibration material 3 FS or better Overload Protection 100 of range Measuring Principle Strain gauge bridge Meas Roller Deflection 0 5 mm max Natural Frequency of Measuring Spring Approx 500 Hz depending on tension range Signal Processing Digital 24 bit A D converter sample time max 5000 s Internal averaging up to 1 s Communication Frequency Approx 100 readings s Output Signal Code 232 57600 Baud 8 ...

Страница 11: ...erating Procedure 3 1 Notes Before Starting Measurement Tensions that exceed the tension range of the instrument by more than 100 may cause permanent damage to the measuring spring and must be avoided under any circumstances HANS SCHMIDT Co GmbH provides no warranty or liability for self made cables The model number the serial number the calibration label option and the SCHMIDT Quality Seal are pr...

Страница 12: ...tension cord Before connecting the AC adapter check the setting for the supply voltage 12 V Hans Schmidt Co GmbH disclaims any warranty or liability and assumes no responsibility whatsoever for AC adapters from other suppliers Code RS 232 Code USB Die Stromversorgung des Sensors erfolgt über den PC Sensor FS USB series USB connecting cable PC ...

Страница 13: ...end special calibration using customer supplied material If the material path is other than vertical or if the process material deviates sig nificantly from the SCHMIDT calibration material you need to carry out static ZERO and GAIN adjustment as described in Chapters 3 4 1 and 3 4 2 3 4 1 ZERO Adjustment Mounting holes 4x Weight fig 3 4a fig 3 4b Material path symbol Measuring roller Guide roller...

Страница 14: ...ERO Adjustment Cont Requirement ZERO adjustment carried out Thread the process material through the measuring and guide rollers following the material path symbol on the front of the sensor Hang a weight that corresponds to e g 95 of the tension range from the process material Start the measuring in the software Adjust the potentiometer which you can reach through the GAIN hole in the housing with...

Страница 15: ...you should make a backup of your hard disk contents before you start installing In no event will HANS SCHMIDT Co GmbH be held liable for any data loss or damage 1 Insert the CD ROM with the Tension Inspect 3 program into the CD ROM drive 2 Start the installation process by double clicking the application file 3 Follow the instructions on the screen to install the software Tension Inspect 3 and the...

Страница 16: ...Button START REC Chapter 4 3 8 5 Menu samplerate SAMPLERATE Select the sampling rate 6 Button AUTO Chapter 4 3 4 7 Menu setup SETUP Chapter 4 3 1 8 Menu alarms ENABLE ALARMS Chapter 4 3 3 Menu alarms SHOW ALARMS Chapter 4 3 3 Menu alarms CLEAR ALARMS Chapter 4 3 3 9 Menu data CLEAR DATA Clear all measuring values Menu data CREATE HTML REPORT Chapter 4 3 5 Menu data EXPORT SCREEN TO EXCEL Chapter 4...

Страница 17: ...rement 16 Display MODEL Display the connected unit 17 Display TIMESHIFTBUFFER Chapter 4 3 4 18 Display TIMESHIFT Chapter 4 3 4 19 Display STATISTICS DIAGRAMM Display the statistical values shown currently at the graph 20 Display READINGS ON SCREEN Chapter 4 3 4 21 Display TENSION Readings as graph as well as the Hi Lo Set points only when activated Enter the COM PORT 1 4 to which the tension meter...

Страница 18: ...3 Hi Lo Set Points Tension Inspect 3 has a comparison function Thereby the displayed value will be com pared with the preset set points During exceeding or underrunning a set point the background of the display TENSION change to red The background of the display NO ALARMS change the colour permanently to red and shows now ALARMS after exceed ing or underrunning a setpoint for one time ENABLE ALARM...

Страница 19: ...MESHIFT To select the timeframe of a series of measurements that should be displayed in the diagram Is the setup Value of READINGS ON SCREEN bigger or equal to the recorded readings the scroll bar cannot be moved Print Click CREAT HTML REPORT in the menu DATA to open the print preview Click the PRINT THIS PAGE button to open the printer setup box The print out includes the statistical data of the ...

Страница 20: ...ings are in the internal memory before opening the existing file the internal memory will be overwritten 4 3 8 Online Recording Click first the button START STOP and afterwards START STOP REC to start the continuously data recording The recorded data is now saved as CSV file If the file reaches a size of 10 MB a new CSV file will be generated automatically for further data aquisition and saving By...

Страница 21: ...ding the ring buffer only USB ASCII Code Function Description d AVG value current value s Fast Value current value z zero set zero t get information request the in formation of the device e g me auring range ASCII Code Function g integration 2 ms h integration 5 ms i integration 10 ms j integration 20 ms k integration 50 ms l integration 100 ms m integration 200 ms n integration 500 ms Ring buffer...

Страница 22: ...y customer No Yes No Yes No Yes Vertification of the calibration Visual inspection and functional test Values within specification Prepare certification for incoming calibration Determination of costs Make of cost estimate Repair and adjustment Verification of the calibration Calibration label on the instrument No Invoice scrapping and disposal Invoice repair and calibration services and dispatch ...

Страница 23: ...r possible misunderstandings please return the instrument with a detailed fault description to our service department Please indicate in your order whether you require an Inspection Certificate 3 1 according to DIN EN 10204 9 Repairs HANS SCHMIDT Co GmbH Schichtstr 16 D 84478 Waldkraiburg Germany Service address Shipping instructions We kindly ask for return free of charge for us if possible by ai...

Страница 24: ...Thickness Gauge Yarn Package Durometer and Shore A Durometer Sample Cutter Balance Moisture Meter Leak Tester Softometer Mailing address P O B 1154 84464 Waldkraiburg Germany Shipping address Schichtstr 16 84478 Waldkraiburg Germany Hans Schmidt Co GmbH Phone int 49 0 8638 9410 0 Fax int 49 0 8638 4825 int 49 0 8638 67898 More than 70 years Worldwide e mail info hans schmidt com Internet http www ...

Отзывы: