1  Warranty and Liability

In principle, the supply of the device is subject to our “General Conditions of Sale and  
Delivery.” These have been provided to the operating company on conclusion of the  
contract, at the latest. 
Warranty: 
- Thickness gauges are warranted for 12 months. 
Parts subject to wear, electronic components and measuring springs are not covered by 
the warranty. No warranty or liability will be accepted for bodily injury or property damage 
resulting from one or several of the following causes: 
- Misuse or abuse of the device. 
- Improper mounting, commissioning, operation and maintenance of the device 
  (e.g. verification interval). 
- Operation of the device if any safeguards are defective or if any safety and protection  
  precautions are not properly installed or not operative. 
- Failure to comply with the notices in the Operating Instructions regarding transport,  
  storage, mounting, commissioning, operation, maintenance and setup of the device. 
- Any unauthorized structural alteration of the device. 
- Insufficient inspection of device components that are subject to wear. 
- Opening the device or improper repair work. 
- Disasters caused by the effects of foreign objects or by force majeure.

1.1  Notices within the Operating Instructions

The fundamental prerequisite for the safe handling of this device and its troublefree opera-
tion is the knowledge of the basic safety notices and safety instructions. 
These Operating Instructions contain the most important notices for the safe operation of 
the device. 
These Operating Instructions, in particular the safety notices, must be observed by any 
person who works with the device. In addition, the applicable local rules and regulations 
for the prevention of accidents must be complied with. 
The representations within the Operating Instructions are not true to scale. 
The dimensions given are not binding. 
General indications of direction, such as FRONT, REAR, RIGHT, LEFT apply when view-
ing the front of the device.

1.2  Responsibilities of the Operating Company

In compliance with the EC Directive 89/655/EEC, the operating company agrees to only 
permit persons to work with the device who: 
- are familiar with the basic regulations on industrial safety and accident prevention and  
  who have been trained in handling the device. 
- have read and understood the chapter on safety and the warning notices in these  
  Operating Instructions and have confirmed this with their signatures. 
- are examined regularly on their safe and conscientious working method. 

1.3  Responsibilities of the Personnel

All persons who work with the device agree to perform the following duties before starting 
work: 
- to observe the basic regulations on industrial safety and accident prevention. 
- to read the chapter on safety and the warning notices in these Operating Instructions and  
  to confirm with their signatures that they have understood them.

Содержание D-2005 Series

Страница 1: ...Thickness Gauge D 2005 Series Edition D 2005 01 E Instruction Manual Valid as of 01 11 2020 Please keep the manual for future reference S C H M I D T c o n t r o l i n s t r u m e n t s ...

Страница 2: ...2 3 Unpacking 6 2 4 Optional Accessories 6 3 Measuring 7 3 1 Notices Before Starting Measurement 7 3 2 Operating Elements 7 3 3 Setup 7 3 4 Preparations Before Measuring 8 3 4 1 Setting the Measurement Parameters 8 3 4 2 Checking and Setting the Zero Point 8 3 5 Operating Procedures 8 3 6 Adjusting the Thickness Gauge to Different Materials 9 3 6 1 Changing the Feeler 9 3 6 2 Load Change 9 3 7 Int...

Страница 3: ...ion is the knowledge of the basic safety notices and safety instructions These Operating Instructions contain the most important notices for the safe operation of the device These Operating Instructions in particular the safety notices must be observed by any person who works with the device In addition the applicable local rules and regulations for the prevention of accidents must be complied wit...

Страница 4: ... works 1 7 Dangers in Handling the Device The device has been designed according to the state of the art and the approved safety standards Nevertheless its use may cause serious or fatal injury to the user or third persons and or an impairment of the device or of other material assets The device may only be applied For its intended use in a faultless condition with regard to the safety requirement...

Страница 5: ...r 2 50 kPa and 100 kPa D 2005 HY DIN EN ISO 54540 Toilet tissue 25 2 kPa D 2005 L DIN EN ISO 2589 Leather 0 785 49 1 kPa D 2005 Gi Rubber 10 5 kPa Feeler Calotte D 2005 F DIN 53370 Foil R 30 mm 0 5 N 2 1 Specifications Measuring Range 0 10 mm Option 0 25 mm or 0 50 mm Resolution 0 01 mm Option 0 001 mm D 2000 P and D 2000 F 0 001 mm Standard Accuracy 0 02 mm up to 0 002 mm optional Units of Measur...

Страница 6: ...or dial gauge Load table 2 3 Unpacking Unpack the thickness gauge and inspect it for any shipping damage Notices of defect must be announced immediately in writing at the latest within 7 days on receipt of the goods 2 4 Optional Accessories Code R Higher resolution 0 001 instead of 0 01 mm Code E25 Higher measuring range 0 25 mm Code E50 Higher measuring range 0 50 mm P DMG Software for data acqui...

Страница 7: ...s gauge on a horizontal flat surface for use Connect the dial gauge to a power supply connect the device with the Sub D9 USB adapter cable to a PC or connect the thickness gauge with the adapter cable and USB AC adapter to a power supply Connect the motor to a power supply Connect the device by using the AC adapter with the power supply Connect the PEDAL SWITCH Switch on the thickness gauge The st...

Страница 8: ...contact with the material to be measured You can now perform the test in accordance with the applicable standard 4 The measured value is shown on the digital display 5 Press and hold the SWITCH PEDAL to raise the FEELER 6 Remove the measured material Start the next measurement from step 1 When you are finished measuring return the FEELER to its home position on the MEASURING TABLE 3 4 Preparations...

Страница 9: ...ave to be exactly parallel 3 6 2 Load Change On some models see chapter 2 you can change the pressure applied to the mate rial This is done by placing an additional weight on the FIXTURE for ADDITIONAL WEIGHTS Use only original weights supplied by the manufacturer to ensure that the correct measuring force is applied according to the relevant standard 3 8 Software optional 3 8 1 Overview The softw...

Страница 10: ...measuring series Minimum value of measuring series Average value of measuring series Standard deviation of measuring series Current actual value of measuring series Batch or part number Number of the current measurement Display of data source see ch 3 8 4 Name of file for measured data Currently selected port see ch 3 8 4 Stops the measurement series Opens the Configuration dialog box see ch 3 8 4...

Страница 11: ...two digits H Hour two digits M Minute two digits S Second two digits N Name entered in the Part Charge number box Data acquisition starts as soon as you click the Init measurement button All the data received from then on will be stored To stop the measurement series click the Stop measurement button You can now ac cess the stored data in the program directory 3 8 4 Basic Settings Click the Config...

Страница 12: ...vise the shipment in advance by fax or eMail Seit 70 Jahren in aller Welt Postadresse P O B 1154 84464 Waldkraiburg Germany Lieferadresse Schichtstr 16 84478 Waldkraiburg Germany Hans Schmidt Co GmbH Telefon int 49 0 8638 9410 0 Fax int 49 0 8638 4825 int 49 0 8638 67898 e mail info hans schmidt com Internet http www hans schmidt com 4 Service and Maintenance The instrument is easy to maintain Dep...

Отзывы: