Translation of Original Operating Instructions
Airport Sweeper / Airport Stand Cleaner
2017-02-02 56
7.19.1.3 Closing
the suction nozzle
channel on the liquid pick-up
unit between the axles
The suction nozzle unit of the liquid pick-up unit
between the axles is closed using a pneumatically
activated shutter gate (1). It is controlled
automatically.
TIP
The gate for the suction between the axles is
closed automatically when the wanderhose
is started.
Gate positions:
Liquid pick-up unit raised
Suction channel closed
Liquid pick-up unit lowered
Suction channel open
7.19.1.4 Opening and closing the
locking plate on the suction
hose
In order for the vacuum created by the blower in the
debris hopper to work within the suction hose, it must
be connected to the debris hopper. The locking plate
can be opened with the blower shut off to do this.
Flap closed (1)
Wanderhose not in use
Flap open (2)
Wanderhose can be put into operation.
After using the wanderhose, the suction nozzle
channels must be opened again and the locking
plate on the suction hose must be closed.
Deactivate the "Wanderhose" menu.
NOTE
Before switching on, open the water pump ball
valve (1) on the water filter
NOTE
Damage to cleaning and water system
►
Completely empty both systems in case
of a danger of frost
1
1
2
11