23
Copyright © 2019 Axxiom Manufacturing, Inc.
3.4
Blast System Air Supply Line
The air supply hose and fittings must be rated at a minimum of 150 psi operating pressure. The
air supply hose from the air compressor to the blast unit should be at least the same diameter as
the air inlet piping (see Section 9.0). This size hose will be large enough to supply the required
airflow to operate the blast unit controls and each blast nozzle. See Section 5.14 for further
information on air hose connection.
Note:
If the abrasive blast system will be installed in a permanent location, the inlet connection
can be hard piped. Do Not install hard piping that is smaller than the piping size of the blast
system. Smaller piping size will reduce the air flow capacity. If other equipment will be using
the same source of air as the abrasive blaster, install a check valve at the air inlet. This will
protect against back flow of air pressure that can carry abrasive into the blast controls.
Hard piping connected to the abrasive blaster must be structurally supported so not to apply any
loading on the pressure vessel at the points of connection. Unsupported piping can create
bending loads at the pressure vessel connections which can cause damage and possible failure.
Hard piping connections to the pressure vessel must be designed and installed by qualified
personnel experienced with piping systems and the applicable codes pertaining to them.
External loading at piping connection can cause damage and possible failure of the pressure
vessel. Hard piping connected to the pressure vessel must include supports to eliminate the
possibility of applying a load on the pressure vessel.
3.5
Blast System Air Pressure
The maximum allowable working pressure (MAWP) for the blast unit is stamped on the ASME
nameplate attached to the vessel. For most abrasive blast systems the MAWP is 150psig. Do
Not exceed the MAWP. An air pressure regulator can be installed to reduce air supply pressure
that is higher than the MAWP. To minimize chance of air pressure backflow only use a non-
relieving air regulator. Air pressure backflow will carry abrasive from the blast vessel and
contaminate the blast control system.
CRITICAL
: A regulator with sufficient air flow capacity
must be selected for proper operation of the blast system. Insufficient air flow capacity will
cause pressure drop in the blast system resulting in equipment malfunction, abrasive backflow,
and reduced blast productivity. Select a valve that will operate with little or no pressure drop
(3psi max.) at the required cfm air flow.
Installing an air pressure regulator allows the option of blasting at low pressure. When blasting
at low pressure the air supply to the deadman blast control system must be at least 80psig. The
valves in the abrasive blast system are “spring closed” and therefore require at least 80psig to
operate properly. If the air pressure regulator is set below 80psig the air supply to the blast
controls must be taken upstream of the regulator.
3.6
Blast System Air Quality
Air quality is crucial to the operation of an abrasive blaster. Moisture and contaminants can
cause components to malfunction. Moisture condensation in a blast system causes abrasive flow
problems. Condensation occurs when the hot vapor-filled compressed air cools as it reaches the
abrasive blaster. Water droplets formed during condensation can be absorbed by the abrasive in
the blast vessel which can cause erratic flow to the abrasive valve. To minimize the chance of
abrasive flow problems a moisture removal device installed for the blast system air supply is
highly recommended (i.e. coalescing moisture separator, air-cooled aftercooler or deliquescent
dryer). Contact a local authorized Schmidt® distributor or Axxiom Manufacturing, Inc. to
locate one near you.
3.7
Electrical Requirements
On units equipped with electric blast controls the supply voltage is 12Vdc or 24Vac. The
maximum power required is:
Each outlet: 7 watts Each outlet with abrasive cutoff:
14 watts
4-outlet: 28 watts 4-outlet with abrasive cutoff:
56 watts
Note:
Insufficient electric power output will result in malfunctioning of the electric blast
control system. A power transformer or power supply can be used if the above voltages are not
readily available.
Содержание AmphiBlast 120
Страница 20: ...20 Copyright 2019 Axxiom Manufacturing Inc 2 6 b Bulk AmphiBlast Dimensional Specifications ...
Страница 21: ...21 Copyright 2019 Axxiom Manufacturing Inc 2 7 Bulk AmphiBlast Strapping Packing Detail ...
Страница 30: ...30 Copyright 2019 Axxiom Manufacturing Inc Figure 5 1 Typical Bulk AmphiBlast With Electric Controls ...
Страница 51: ...51 Copyright 2019 Axxiom Manufacturing Inc Figure 7 1 Typical Bulk AmphiBlast With Electric Controls ...
Страница 60: ...60 Copyright 2019 Axxiom Manufacturing Inc Figure 8 4 Typical Bulk AmphiBlast With Electric Controls ...
Страница 66: ...66 Copyright 2019 Axxiom Manufacturing Inc This page was intentionally left blank ...
Страница 68: ...68 Copyright 2019 Axxiom Manufacturing Inc 9 1 a Bulk AmphiBlast Pneumatic Control System Parts List ...
Страница 69: ...69 Copyright 2019 Axxiom Manufacturing Inc 9 1 b Bulk AmphiBlast with Pneumatic Control System Side View ...
Страница 70: ...70 Copyright 2019 Axxiom Manufacturing Inc 9 1 c Bulk AmphiBlast with Pneumatic Control System Back View ...
Страница 71: ...71 Copyright 2019 Axxiom Manufacturing Inc 9 1 d Bulk AmphiBlast Water Panel Back View ...
Страница 72: ...72 Copyright 2019 Axxiom Manufacturing Inc 9 1 e Bulk AmphiBlast Pneumatic Panel Schematic for Outlets 1 and 2 ...
Страница 74: ...74 Copyright 2019 Axxiom Manufacturing Inc 9 1 g Bulk AmphiBlast Pneumatic Control System Schematic ...
Страница 75: ...75 Copyright 2019 Axxiom Manufacturing Inc 9 2 a Bulk AmphiBlast Electric Control System Parts List ...
Страница 76: ...76 Copyright 2019 Axxiom Manufacturing Inc 9 2 b Bulk AmphiBlast with Electric Control System Side View ...
Страница 77: ...77 Copyright 2019 Axxiom Manufacturing Inc 9 2 c Bulk AmphiBlast with Electric Control System Back View ...
Страница 78: ...78 Copyright 2019 Axxiom Manufacturing Inc 9 2 d Bulk AmphiBlast Water Panel Back View ...
Страница 79: ...79 Copyright 2019 Axxiom Manufacturing Inc 9 2 e Bulk AmphiBlast Electric Panel Schematic for Outlet 1 and 2 ...
Страница 80: ...80 Copyright 2019 Axxiom Manufacturing Inc 9 2 f Bulk AmphiBlast Electric Panel Schematic for Outlet 3 and 4 ...
Страница 81: ...81 Copyright 2019 Axxiom Manufacturing Inc 9 2 g Bulk AmphiBlast Electric Control System Schematic ...
Страница 82: ...82 Copyright 2019 Axxiom Manufacturing Inc 9 3 a Vessel and Trailer Assembly ...
Страница 83: ...83 Copyright 2019 Axxiom Manufacturing Inc 9 3 b Vessel and Trailer Parts List ...
Страница 84: ...84 Copyright 2019 Axxiom Manufacturing Inc 9 4 Thompson Valve II with Diverter Plate ...
Страница 85: ...85 Copyright 2019 Axxiom Manufacturing Inc 9 5 Automatic Air Valve normally closed ...
Страница 86: ...86 Copyright 2019 Axxiom Manufacturing Inc 9 6 Control Valves Pneumatic and Electric ...
Страница 87: ...87 Copyright 2019 Axxiom Manufacturing Inc 9 7 Water Control Valve ...
Страница 88: ...88 Copyright 2019 Axxiom Manufacturing Inc 9 8 a G2 Pneumatic Deadman ...
Страница 89: ...89 Copyright 2019 Axxiom Manufacturing Inc 9 8 b Deadman Valves Pneumatic ...
Страница 91: ...91 Copyright 2019 Axxiom Manufacturing Inc 9 10 AmphiBlast Injection Module ...
Страница 92: ...92 Copyright 2019 Axxiom Manufacturing Inc 9 11 Vacuum Loading System ...
Страница 93: ...93 Copyright 2019 Axxiom Manufacturing Inc 9 12 Palm Detent Control Valve ...
Страница 94: ...94 Copyright 2019 Axxiom Manufacturing Inc 9 13 Halok Assembly ...
Страница 96: ...96 Copyright 2019 Axxiom Manufacturing Inc This page was intentionally left blank ...
Страница 98: ...98 Copyright 2019 Axxiom Manufacturing Inc Figure 11 1 Typical Bulk AmphiBlast With Electric Controls ...
Страница 111: ...111 Copyright 2019 Axxiom Manufacturing Inc 14 0 Water Pump Manual ...
Страница 112: ...112 Copyright 2019 Axxiom Manufacturing Inc ...
Страница 113: ...113 Copyright 2019 Axxiom Manufacturing Inc ...
Страница 114: ...114 Copyright 2019 Axxiom Manufacturing Inc ...
Страница 115: ...115 Copyright 2019 Axxiom Manufacturing Inc ...
Страница 116: ...116 Copyright 2019 Axxiom Manufacturing Inc ...