LED Measured Value Display MD 10.010
Page 10
Standard mode
After a successful initialization phase, the
MD 10.010
enters its standard
operation mode as
“measured value display” (see Figure 4). The main
display shows the current measured value and the status of the alarm out-
puts are depicted in the auxiliary display (see Table 3).
Display
State
Alarm output 1: Not activated
Alarm output 2: Not activated
Alarm output 1: Activated
Alarm output 2: Not activated
Alarm output 1: Not activated
Alarm output 2: Activated
Alarm output 1: Activated
Alarm output 2: Activated
Table 3
Handling
The device can be operated by means of two different menus which are
activated from standard mode using the parameter key
.
Shortly press the parameter key to open the display menu. In this menu,
the actual measured values, the stored peak values (minimum and maxi-
mum) as well as the switching points of the alarm outputs can be sequen-
tially selected by further pressing of the parameter key. If the key is
n’t
pressed for more than 2 minutes, the device returns automatically to
standard mode.
If the parameter key is pressed for more than 2 seconds, the configuration
menu opens. It can be used to configure the measuring input (sensor sig-
nal), both alarm outputs and the analog output (details see
chapter 7
).
The menu items are selected sequentially by using the parameter key.
The settings of the currently selected menu item can be modified using
the arrow keys (
).
The configuration menu is left automatically after the last menu item or if
no key is pressed for more than 2 minutes. It can also be quitted at any
time by a long press (more than 2 seconds) of the parameter key.
Table 4 shows an overview of the presentation and meaning of the differ-
ent menu items.