T.FH 232-..UEDR..
Operating instructions
Safety foot switches
EN
2.4 Technical data
Standards:
EN 60947-5-1,
DIN VDE 0660-200, BG-GS-ET-15
Material of the enclosure,
cover and protective shield:
aluminium
Enclosure coating:
powder-coated thermoplastic
Material of the pedal:
glass-fibre reinforced thermoplastic
Mechanical data
Execution of the electrical connection:
screw terminals
Cable section:
2.5 mm²
(incl. conductor ferrules)
Cable entry:
1-pedal: 1 x M20 x 1.5;
2-pedal: 2 x M25 x 1.5
Mechanical life:
> 1,000,000 operations
Switching frequency:
max. 1/s
Resistance to shock:
30 g / 11 ms
Resistance to vibration:
10 … 150 Hz
(0.35 mm / 5 g)
Ambient conditions
Ambient temperature:
−25 °C…+60 °C
Storage and transport temperature:
−25 °C…+85 °C
Relative humidity:
30% … 95%
- no condensation
- no icing
Protection class:
IP65 to IEC/EN 60529
Overvoltage category:
III
Degree of pollution:
3
Electrical data
Execution of the control element:
NC contact, NO contact
Switching principle:
Slow action switching contacts
Rated impulse withstand voltage U
imp
:
6 kV
Rated insulation voltage U
i
:
500 V
Thermal test current I
the
:
10 A
Utilisation category:
DC-13: 24 V / 1 A;
AC-15: 230 V / 4 A
Required short-circuit current:
1000 A
Max. fuse rating:
6 A gG D-fuse
Dimensions:
1-pedal: 170 x 189 x 274 mm;
2-pedal: 295 x 189 x 274 mm
2.5 Safety classification
Standards:
EN ISO 13849-1
B
10d
(NC contact):
100,000
Service life:
20 years
MTTF
B
d
x
x
h
s/h
3600
d
10d
op
op
op
n
0,1 x n
op
t
cycle
(Specifications can vary depending on the application-specific para-
meters h
op
, d
op
and t
cycle
as well as the load.)
If multiple safety components are wired in series, the Performance
Level to EN ISO 13849-1 will be reduced due to the restricted error
detection under certain circumstances.
3. Mounting
3.1 Dimensions
All measurements in mm.
with 1 foot pedals
274
84
2,2
189
48
69
170
M6
45
49
100
¤33
with 2 foot pedals
84
2,2
48
69
189
255
75
75
125
207
274
295
M25x1,5
45
174
M6
100
¤33
4. Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by
authorised personnel in a de-energised condition.
The contact labelling can be found in the wiring compartment of the
switch. For the cable entry, suitable cable glands with an appropriate
degree of protection must be used. The cables must be laid correctly in
the wiring compartment of the switch. For foot switches with 1 foot ped-
al, the M20 x 1.5 cable entry is available, for foot switches with 2 foot
pedals, 2x M25 x 1.5. The non-used cable entry must be sealed with
blanking plugs. After wiring, the wiring compartment of the switch must
definately be cleaned (e.g. removal of cables residues), considering
that foreign bodies can affect the switching behaviour. The tightening
torque for the cover screws is min. 1.8 Nm.