9.  Declaration of conformity

The currently valid declaration of conformity can be  
downloaded from the internet at www.schmersal.net.

9.1  EC Declaration of conformity

Name of the safety component:

SRB301STV.2;
SRB301ST/CCV.2;
SRB301ST/PCV.2;
SRB301STV.3;
SRB301ST/CCV.3;
SRB301ST/PCV.3

Description of the safety component:

Safety-monitoring module for emergency 
stop circuits, guard door monitoring,  
magnetic safety switches and AOPD's

Relevant EC-Directives:

2006/42/EC EC-Machinery Directive
2004/108/EC EMC-Directive
1995/16/EG EC-Lift Directive

Person authorised for the compilation 
of the technical documentation:

Oliver Wacker
Möddinghofe 30
42279 Wuppertal

Notiied body:

TÜV Rheinland Industrie Service GmbH
ID n°: 0035

Place and date of issue:

Wuppertal, July 06, 2015

Authorised signature

Philip Schmersal

Managing Director

EC Declaration of conformity

Translation of the original  
Declaration of Conformity

K.A. Schmersal GmbH & Co. KG

Industrielle Sicherheitsschaltsysteme
Möddinghofe 30, 42279 Wuppertal
Germany
Internet: www.schmersal.com

We hereby certify that the hereafter described safety components both in its basic design and  
construction conform to the applicable European Directives.

Содержание SRB301ST/PCV.2

Страница 1: ...ust be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the...

Страница 2: ...11 S12 and or S21 S22 are opened The safety relevant current paths with the outputs contacts 13 14 23 24 and 33 34 meet the following requirements under observation of a PFH value assessment also refe...

Страница 3: ...for electrical connection As far as the electrical safety is concerned the protection against unintentional contact of the connected and therefore electrically interconnected apparatus and the insulat...

Страница 4: ...ch the components after electrical discharge Setting the switch see Fig 3 The cross wire short monitoring function factory setting is pro grammed by means of the switch underneath the front cover of t...

Страница 5: ...reset button e g welded contacts or manipulations which could lead to an inadvertent restart are detected in this configuration and will result in an inhibition of the operation Automatic start see Fi...

Страница 6: ...he control circuits are detected Cross wire shorts between the control circuits are not detected Category 3 PL e to DIN EN ISO 13849 1 possible Dual channel control of magnetic safety switches accordi...

Страница 7: ...nt EC Directives 2006 42 EC EC Machinery Directive 2004 108 EC EMC Directive 1995 16 EG EC Lift Directive Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe...

Страница 8: ...A Schmersal GmbH Co KG M ddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal c...

Отзывы: