schmersal SRB-E-402ST Скачать руководство пользователя страница 5

5

SRB-E-402ST

Operating instructions

Safety-monitoring module

EN

5.2   Applications for two safety functions can be set separately using rotary mode switch 1 and 2

Rotary knob 

position

Reset button (detection 

of the trailing edge)

Cross-wire 

monitoring active

Input / Sensor 

configuration 

Monitoring of sensor channels for 

synchronisation (< 5 sec.)

1

Yes

Yes

NC / NC

Yes

2

Yes

Yes

NC / NC

No

3

Yes

No

NC / NC

Yes

4

Yes

No

NC / NC

No

5

Yes

Yes

NC / NO

Yes

6

Autostart

Yes

NC / NO

No

7

Autostart

Yes

NC / NC

Yes

8

Autostart

Yes

NC / NC

No

9

Autostart

No

NC / NC

Yes

10

Autostart

No

NC / NC

No

11

Two-hand function type IIIC  

Only rotary mode switch 2

NC, NO / NC, NO

< 0.5 sec.  

(upon actuation of setting elements)

12

Two-hand function type IIIA  

Only rotary mode switch 2

NO / NO

< 0.5 sec.  

(upon actuation of setting elements)

C

Configuration mode

5.3  Changing setting or application

Description / procedure

Rotary (mode) switch

System response

LED indications

RUN

In 1/2

In 3/4

Out 1

Out 2

Factory setting

mode 1 and mode 2 in position 1 Ready for application 1

-

-

-

-

-

Switch operating voltage on

Position 1

Without connected sensors!

Lights up

-

-

-

-

Turn rotary mode switch 1  
to position C

Application 1 is deleted

Lights up Flashes Flashes Flashes Flashes

Setting cycle active

Application 1 is deleted

-

-

-

-

-

No valid application stored

Flashes

-

-

-

-

SRB-E ready for new applications

Select mode 2, application 2 Select desired application (1-11)

Flashes

-

-

-

-

Select mode 1, application 1 Set desired application (1-10) 

 (time window for setting 
procedure approx. 3 sec.)

New applications will be loaded Lights up

-

-

-

-

Setting cycle active

Lights up Lights up

-

-

-

Lights up Lights up Lights up

-

-

Lights up Lights up Lights up Lights up

-

Lights up Lights up Lights up Lights up Lights up

Ready for operation

The desired applications are 
configured

Adopt new application

Lights up

-

-

-

-

Switch off operating voltage and connect wires according to selected application -> SRB-E... ready for operation

Adjustment of application using rotary “mode” switch

•  Open front transparent cover (see fig.).

•  Opening is carried out by lifting side with lock.

•  Select desired application for safety function 2 using rotary mode 

switch 2 (1 … 11) by turning up or down (see 5.3). 

•  Select desired application for safety function 1 using rotary mode 

switch 1 (1 … 10) by turning up or down (see 5.3).

•  After performing setting, close front cover again.

•  Front cover can be secured with a lead seal to protect it from being 

opened unintentionally

Only touch the components after electrical discharge!

Содержание SRB-E-402ST

Страница 1: ...e could lead to physical injury and or damage to the machine Content 1 About this document 1 1 Function 1 1 2 Target group authorised qualified personnel 1 1 3 Explanation of the symbols used 1 1 4 Ap...

Страница 2: ...elay module is to be operated in an area in which access by personnel is restricted 2 Product description 2 1 Ordering code This operating instructions manual applies to the following types SRB E 402S...

Страница 3: ...0 Inductive consumers provision is to be made for suitable protective wiring for suppression Mechanical data Connection type refer to 2 1 Cable section refer to 2 1 Connecting cable rigid or flexible...

Страница 4: ...etic Compatibility EMC of DIN EN 60204 1 4 2 Coding of connecting terminals 5 Operating principle and settings 5 1 Description of the terminals and LED indications Pin Function LED Function A1 Operati...

Страница 5: ...sition C Application 1 is deleted Lights up Flashes Flashes Flashes Flashes Setting cycle active Application 1 is deleted No valid application stored Flashes SRB E ready for new applications Select mo...

Страница 6: ...of contactors or relays with positive guided contacts H2 Feedback circuit Signalling outputs must not be used in safety circuits 6 Diagnostic 6 1 LED indications LED Function Display type RUN Ready f...

Страница 7: ...position 6 Rotary knob position 2 Rotary knob position 7 Rotary knob position 3 Rotary knob position 8 Rotary knob position 4 Rotary knob position 9 Rotary knob position 5 Rotary knob position 10 7 4...

Страница 8: ...S32 S42 S31 S41 S32 S42 S31 S41 24VDC S12 S22 Rotary knob position Function 5 Reset button detection of the trailing edge 6 Reset without monitoring autostart Two hand control type IIIC safety functi...

Страница 9: ...chine Machine n Machine type Module n Configured application mode 1 Configured application mode 2 Set on date Signature of the responsible person 8 5 Maintenance A regular visual inspection and functi...

Страница 10: ...35 EC prototype test certificate 01 205 5365 00 18 Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal J...

Отзывы: