![schmersal SRB-E-402ST Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/schmersal/srb-e-402st/srb-e-402st_operating-instructions-manual_1213146005.webp)
5
SRB-E-402ST
Operating instructions
Safety-monitoring module
EN
5.2 Applications for two safety functions can be set separately using rotary mode switch 1 and 2
Rotary knob
position
Reset button (detection
of the trailing edge)
Cross-wire
monitoring active
Input / Sensor
configuration
Monitoring of sensor channels for
synchronisation (< 5 sec.)
1
Yes
Yes
NC / NC
Yes
2
Yes
Yes
NC / NC
No
3
Yes
No
NC / NC
Yes
4
Yes
No
NC / NC
No
5
Yes
Yes
NC / NO
Yes
6
Autostart
Yes
NC / NO
No
7
Autostart
Yes
NC / NC
Yes
8
Autostart
Yes
NC / NC
No
9
Autostart
No
NC / NC
Yes
10
Autostart
No
NC / NC
No
11
Two-hand function type IIIC
Only rotary mode switch 2
NC, NO / NC, NO
< 0.5 sec.
(upon actuation of setting elements)
12
Two-hand function type IIIA
Only rotary mode switch 2
NO / NO
< 0.5 sec.
(upon actuation of setting elements)
C
Configuration mode
5.3 Changing setting or application
Description / procedure
Rotary (mode) switch
System response
LED indications
RUN
In 1/2
In 3/4
Out 1
Out 2
Factory setting
mode 1 and mode 2 in position 1 Ready for application 1
-
-
-
-
-
Switch operating voltage on
Position 1
Without connected sensors!
Lights up
-
-
-
-
Turn rotary mode switch 1
to position C
Application 1 is deleted
Lights up Flashes Flashes Flashes Flashes
Setting cycle active
Application 1 is deleted
-
-
-
-
-
No valid application stored
Flashes
-
-
-
-
SRB-E ready for new applications
Select mode 2, application 2 Select desired application (1-11)
Flashes
-
-
-
-
Select mode 1, application 1 Set desired application (1-10)
(time window for setting
procedure approx. 3 sec.)
New applications will be loaded Lights up
-
-
-
-
Setting cycle active
Lights up Lights up
-
-
-
Lights up Lights up Lights up
-
-
Lights up Lights up Lights up Lights up
-
Lights up Lights up Lights up Lights up Lights up
Ready for operation
The desired applications are
configured
Adopt new application
Lights up
-
-
-
-
Switch off operating voltage and connect wires according to selected application -> SRB-E... ready for operation
Adjustment of application using rotary “mode” switch
• Open front transparent cover (see fig.).
• Opening is carried out by lifting side with lock.
• Select desired application for safety function 2 using rotary mode
switch 2 (1 … 11) by turning up or down (see 5.3).
• Select desired application for safety function 1 using rotary mode
switch 1 (1 … 10) by turning up or down (see 5.3).
• After performing setting, close front cover again.
• Front cover can be secured with a lead seal to protect it from being
opened unintentionally
Only touch the components after electrical discharge!