![schmersal SLG 422 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/schmersal/slg-422/slg-422_operating-manual_1213276020.webp)
1 White
2 Brown
3 Green
4 Yellow
5 Grey
6 Pink
7 Blue
8 Red
The following arrangement shows the sensor connection with the individual connectors:
Muting sensor 1/ machine contact MC, muting sensor 2, muting lamp
6.5 Power supply
The external power supply (+24V/DC) must comply with EN 60204. Furthermore the following requirements
must be fulfilled:
- A short-term power outage of 20 ms must be bridged by the power supply.
- The power supply unit has double insulation between the primary and the secondary side.
- The power supply is protected against overload.
- The power supply fulfills the regulations of the EEC (industrial environment).
- The power supply fulfills the low voltage directive.
- The grounded conductor of the power supply unit should be connected to a grounding point PE.
- The voltage levels must be within the limits (24VDC +/- 10%).
Subject to technical changes
Page 17
Safety light grid SLG 422/ 425I-P
Diagnosis OUT
Power supply
6.3 Connection of cables
Input
Freigabe/Override
Designation
SLG 422/425 IP
Top view of plug
Pin Nr. / Color
Description
Signal
Input
EDM/Conveyor stop
24 V DC
Input Diagnostic data
Safety Output 1
OSSD 1
Safety Output 2
Power supply
Output Diagnostic data
0 V DC
OSSD 2
Diagnosis IN
6.4 Sensor connection
MS1 / MC
MS2
M L
1
2
5
8
3
4
6
7
1
2
5
8
3
4
6
7