schmersal PDM-SD-4CC-SD Скачать руководство пользователя страница 8

8

Operating instructions

Passive distribution module

PDM-SD-4CC-SD

EN

5. Set-up and maintenance

5.1  Functional testing

A check must be carried out to ensure that the projected safety function 

is effective.

The safety function, the DIP switch configuration and 

correct installation must be checked by the responsible 

safety specialist / safety representative.

5.2  Maintenance

If installed correctly and used as intended, the passive distribution 

module requires no maintenance.

6. Disassembly and disposal

6.1  Disassembly

The passive distribution module may only be removed when 

de-energised.

6.2  Disposal

The passive distribution module is to be disposed of in the correct 

 manner as per the national regulations and legislation.

7. Configuration

7.1  Configuration examples

3 configurations are shown respectively for the different SCHMERSAL devices. One configuration with long cable lengths (maximum), 

one configuration with medium cable lengths (medium) and one configuration with shorter cable lengths (small).

The following assumptions are made for the configuration examples listed in the table:

•  The examples represent maximum configurations. If individual cable lengths are shortened, larger systems are possible

•  1.5 mm² power supply wiring and 10 A fuse protection

•  Use of SCHMERSAL cables

•  The cable lengths listed in the table between power supply and the 1st module as well as between the modules are maximum lengths.

Reducing the individual cable lengths is not critical.

Device / configuration  

version

Max. number  

of devices

Equals number 

of modules

Length of cable (A) 

until 1st module

Length of cables (B)  

between the modules

Length of stub cables (C) 

for device connection

AZM 200 / Maximum

10

2.5

10.0 m

10.0 m

7.5 m

AZM 200 / Medium

12

3

7.5 m

7.5 m

5.0 m

AZM 200 / Small

16

4

7.5 m

5.0 m

3.5 m

MZM 100 / Maximum

12

3

10.0 m

10.0 m

7.5 m

MZM 100 / Medium

16

4

7.5 m

7.5 m

5.0 m

MZM 100 / Small

18

4.5

7.5 m

5.0 m

3.5 m

AZM 300 / Maximum

16

4

10.0 m

10.0 m

7.5 m

AZM 300 / Medium

20

5

7.5 m

7.5 m

5.0 m

AZM 300 / Small

24

6

7.5 m

5.0 m

3.5 m

RSS & CSS / Maximum

28

7

10.0 m

10.0 m

7.5 m

RSS & CSS / Medium

31

8

7.5 m

7.5 m

5.0 m

RSS & CSS / Small

31

8

7.5 m

5.0 m

3.5 m

Mixed / Maximum

16

4

10.0 m

10.0 m

7.5 m

Mixed / Medium

18

4.5

7.5 m

7.5 m

5.0 m

Mixed / Small

22

5.5

7.5 m

5.0 m

3.5 m

Mixed fitting of module:

 2 x MZM 100, 1 x AZM 300 and 1 x RSS / CSS

(A)

(B)

(C)

(B)

(C)

(C)

24 VDC

Power

Distribution 

module

Distribution 

module

Distribution 

module

Devices

Devices

Devices

K. A. Schmersal GmbH & Co. KG

Möddinghofe 30, D - 42279 Wuppertal

Postfach 24 02 63, D - 42232 Wuppertal 

Phone:  +49 - (0)2 02 - 64 74 - 0 

Telefax:  +49 - (0)2 02 - 64 74 - 1 00

E-Mail: [email protected]

Internet: http://www.schmersal.com

Содержание PDM-SD-4CC-SD

Страница 1: ...y be used in accordance with the following versions or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product...

Страница 2: ...D 4CC SD passive distribution module the secure OSSD outputs of the connected safety switchgear units are connected in series and wired to a relevant safety monitoring module The non secure SD interfa...

Страница 3: ...d condition It is possible to connect wires with and without conductor ferrules with a wire cross section of 0 25 mm to 1 5 mm to the terminals of the passive distribution module The supply voltage of...

Страница 4: ...device connection Pin assignment of safety switchgear connection Function safety switchgear Pin assignment of connector plug or conductor numbers Colour code of the Schmersal connector to DIN 47100 C...

Страница 5: ...2 A1 24 VDC device supplied I Device SD input O Device SD output A2 0 VDC device supplied X1 Safety input 1 X2 Safety input 2 Pin assignment of safety switchgear 2 Y1 Safety output 1 Y2 Safety output...

Страница 6: ...y IN 2 Safety IN 1 0 VDC 24 VDC 10A O N 1 8 7 6 5 4 3 2 1 2 3 4 I1 I2 I3 I4 O1 O2 O3 O4 SD Out 0 VDC 24 VDC SD Out SD In FB PLC Power supply Safety monitoring Safety switchgear Module in middle SW 7 8...

Страница 7: ...A2 X1 X2 A1 A2 X1 X2 I O Y1 Y2 Y2 Y1 A2 A1 I1 I2 I3 I4 O1 O2 O3 O4 A1 A2 X1 X2 A1 A2 X1 X2 I O Y1 Y2 O N 1 8 7 6 5 4 3 2 O N 1 8 7 6 5 4 3 2 1 2 1 2 3 I1 I2 I3 I4 O1 O2 O3 O4 Module in middle SW 7 8 O...

Страница 8: ...er supply wiring and 10 A fuse protection Use of SCHMERSAL cables The cable lengths listed in the table between power supply and the 1st module as well as between the modules are maximum lengths Reduc...

Отзывы: