Operating instructions

Passive distribution module

PDM-SD-4CC-SD

EN

1.6  Warning about misuse

In the event of improper or unintended use or tampering, 

use of the passive distribution module could expose 

persons to danger or cause damage to the machine or 

system components.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages result-

ing from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-

pairs, conversions and modifications to the device are strictly forbidden; 

the manufacturer shall accept no liability for damages resulting from 

such invasive work, arbitrary repairs, conversions and/or modifications 

to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

PDM-SD-4CC-SD
Option

Description

PDM

Passive distribution module

SD

Evaluation side: SD interface

4CC

4 device connections with cage clamps

SD

Device connection: SD interface

2.2  Destination and use

The PDM-SD-4CC-SD passive distribution module is designed for the 

connection of 4 electronic safety switchgear units with SD interface 

manufactured by SCHMERSAL. It serves to connect up to 4 safety 

switchgear units in series.

To increase the safety functionality, more passive distribution modules 

can also be connected in series.

With the PDM-SD-4CC-SD passive distribution module, the secure 

OSSD outputs of the connected safety switchgear units are connected 

in series and wired to a relevant safety-monitoring module.

The non-secure SD interface signals of the devices are connected in 

series and wired to an SD Gateway.

The user must evaluate and design the safety chain in 

accordance with the relevant standards and the required 

safety level.

2.3  Technical data

Standards:

 

IEC 60947-1

Material of housing:

 

Plastic, polyamide 66

Mounting:

 

35 mm standard rail in  

accordance with EN 60715

Mechanical data 

Type of connection:

 

Clips, cage clamps

Cable section:

 

min. 0.25 mm², max. 1.5 mm²  

(including conductor ferrules)

De-insulation length:

 

5 … 6 mm

Actuator tool blade:

 

3.5 x 0.5 mm

Ambient conditions 

Ambient temperature:

 

−25 °C … +65 °C

Storage and transport temperature:

 

−40 °C … +85 °C

Relative humidity:

 

5 % … 95 %, non condensing

Resistance to shock:

 

30 g / 11 ms

Resistance to vibration:

 

10 ... 55 Hz, amplitude 1 mm

Protection class:

 

IP00 to IEC 60529

Protection class:

 III

Insulation values to IEC 60664-1: 

 

- Rated insulation voltage Ui:

 

32 VDC 

- Rated impulse withstand voltage U

imp

:

 

0.8 kV 

- Over-voltage category:

 III 

- Degree of pollution:

 2

Electrical data 

Supply voltage U

B

:

 

24 VDC -15% / +10%  

(stabilised PELV mains unit)

Rated operating voltage U

e

 

24 VDC

Operating current I

e

 

- Distribution module (external fuse needed):

 

10 A  

- Device connection (internal fuse fitted):

 

1.5 A  

- Safety outputs Y1 and Y2:

 

0.1 A

Device connection line fuse:

 

Automatically resetting  

fuse element 1.5 A

LED indications 

Green “Power” LED:

 

Distribution module supply voltage

Green “F4” LED:

 

Device connection 4 fuse element

Green “F3” LED:

 

Device connection 3 fuse element

Green “F2” LED:

 

Device connection 2 fuse element

Green “F1” LED:

 

Device connection 1 fuse element

Содержание PDM-SD-4CC-SD

Страница 1: ...y be used in accordance with the following versions or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product...

Страница 2: ...D 4CC SD passive distribution module the secure OSSD outputs of the connected safety switchgear units are connected in series and wired to a relevant safety monitoring module The non secure SD interfa...

Страница 3: ...d condition It is possible to connect wires with and without conductor ferrules with a wire cross section of 0 25 mm to 1 5 mm to the terminals of the passive distribution module The supply voltage of...

Страница 4: ...device connection Pin assignment of safety switchgear connection Function safety switchgear Pin assignment of connector plug or conductor numbers Colour code of the Schmersal connector to DIN 47100 C...

Страница 5: ...2 A1 24 VDC device supplied I Device SD input O Device SD output A2 0 VDC device supplied X1 Safety input 1 X2 Safety input 2 Pin assignment of safety switchgear 2 Y1 Safety output 1 Y2 Safety output...

Страница 6: ...y IN 2 Safety IN 1 0 VDC 24 VDC 10A O N 1 8 7 6 5 4 3 2 1 2 3 4 I1 I2 I3 I4 O1 O2 O3 O4 SD Out 0 VDC 24 VDC SD Out SD In FB PLC Power supply Safety monitoring Safety switchgear Module in middle SW 7 8...

Страница 7: ...A2 X1 X2 A1 A2 X1 X2 I O Y1 Y2 Y2 Y1 A2 A1 I1 I2 I3 I4 O1 O2 O3 O4 A1 A2 X1 X2 A1 A2 X1 X2 I O Y1 Y2 O N 1 8 7 6 5 4 3 2 O N 1 8 7 6 5 4 3 2 1 2 1 2 3 I1 I2 I3 I4 O1 O2 O3 O4 Module in middle SW 7 8 O...

Страница 8: ...er supply wiring and 10 A fuse protection Use of SCHMERSAL cables The cable lengths listed in the table between power supply and the 1st module as well as between the modules are maximum lengths Reduc...

Отзывы: