background image

2

Operating instructions

Position switches

EX-T 335

EN

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of 

the component, personal hazards or damage to machinery 

or plant components cannot be excluded. The relevant 

requirements of the standard ISO 14119 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories. 

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

EX-T

➀ 

335-

Y

-

-

No. Option

Description

Actuator selection, refer to catalogue

11

1 NO  / 1 NC 

02

2 NC 

20

2 NO

UE

With overlapping contacts

with staggered contacts

2138

Roller lever 7H for safety applications

RMS

Brass actuating roller

In accordance with the Machinery Directive, the type 

plate of safety components is type plate is labelled "safety 

component".

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and 

therefore the compliance with the Machinery Directive and 

the Explosion Protection Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Purpose

The position switches are suitable for sliding and hinged guards, which 

need to be closed in order to ensure the required operational safety.

The components can be used in explosion-endangered areas of Zone 

1 and 21 equipment category 2GD. The installation and maintenance 

requirements to the standard series EN IEC 60079  

(ABNT NBR IEC 60079) must be met.

The user must evaluate and design the safety chain in ac-

cordance with the relevant standards and the required safety 

level.

The entire concept of the control system, in which the safety 

component is integrated, must be validated to the relevant 

standards.

The safety-technical data and features according to the 

applicable test certificate (or possible other approvals) are 

mentioned in the technical data.

2.4  Technical data

Designation in accordance with the ATEX Directive:

 

L

 II 2GD

Designation in accordance with the standards:

 

Ex db eb IIC T6 Gb  

Ex tb IIIC T80°C Db

Applied standards:

 

EN 60947-5-1, EN 60079-0,  

EN 60079-1, EN IEC 60079-7, EN 60079-31,  

ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-1,  

ABNT NBR IEC 60079-7, ABNT NBR IEC 60079-31

Certificate numbers:

 

 

- EU-prototype test certificate: 

 

BVS 09 ATEX E 152    

- IECEx: 

 

BVS 10.0040  

- INMETRO: 

 

DNV 14.0041

 

Enclosure:

 

zinc die-cast, paint finish

Design:

 

EN 50041

Design according to ISO 14119:

 1

Max. impact energy:

 

7 J

Actuating speed:

 

max. 1 m/s

Protection class:

 IP65

Contact material:

 Silver

Contact type:

 

change-over with double break Zb,  

or 2 NC contacts, galvanically separated contact bridges

Switching system:

 

A

 EN 60947-5-1, slow action,  

NC contact with positive break

Connection:

 

screw terminals

Max. cable section:

 

1 mm² … 2.5 mm²  

(incl. conductor ferrules)

Cable entry:

 M20

Rated impulse withstand voltage U

imp

:

 

4 kV

Rated insulation voltage U

i

:

 

250 V

Thermal test current I

the

:

 

5 A

Utilisation category:

 

AC-1, AC-15, DC-13

Max. fuse rating:

 

6 A gG D-fuse

Required short-circuit current: 

1,000 A

Ambient temperature: 

 

- cable section 2.5 mm²

 

–20 °C … +55 °C 

- cable section 1 mm²

 

–20 °C … +50 °C

Mechanical life:

  

1 million operations

Max. switching frequency:

 1,800/h

Bounce duration:

 

Slow action: < 3 ms

Switchover time:

 

in accordance with actuating speed

Cable cross-section of the cable glands:

 

min. Ø 7 mm;  

max. Ø 12 mm

Cable glands:

 

L

 II 2GD  

(1,21 ABNT NBR IEC 60079)

Tightening torque:

 

 

- Cover screws: 

 

min. 1.4 Nm 

- Head screws: 

 

min. 1.5 Nm 

- Screwed cable gland/Cap nut: 

 

10 Nm 

- Earth screw: 

 

min. 1 Nm

Maximum ambient temperature: 55°C.

The power-source has to be an isolated limited voltage/limited 

current protected by maximum 30Vdc, 4A (42.4Vdc peak).

2.5  Safety classification

Standards:

 

ISO 13849-1

B

10D

 (NC contact):

 20.000.000

B

10D 

(NO contact) at 10% ohmic contact load:

 1,000,000

Service life:

 

20 years

MTTF

B

d x

x

h

s/h

3600

D

10D

op

op

op

n

0,1 x n

op

t

cycle

(Specifications can vary depending on the application-specific 

parameters h

op

, d

op

, t

cycle

 as well as the load.)

Содержание EX-T 335

Страница 1: ...tire machine or plant The product must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific...

Страница 2: ...n in ac cordance with the relevant standards and the required safety level The entire concept of the control system in which the safety component is integrated must be validated to the relevant standards The safety technical data and features according to the applicable test certificate or possible other approvals are mentioned in the technical data 2 4 Technical data Designation in accordance wit...

Страница 3: ...the guidance of the actuating system The actuation of the switch beyond its end stop however must be avoided Please observe the recommendations regarding maximum impact energy actuating speed and tightening torque in the technical data Please observe the relevant requirements of the standards ISO 12100 ISO 14119 and ISO 14120 3 2 Dimensions All measurements in mm 76 40 5 30 7 3 5 3 60 66 5 30 5 6 ...

Страница 4: ... the inside of the arm Positioning the lever H 10 10 10 10 The roller lever can be repositioned over 360 on the toothed shaft in 10 steps Unscrew the hexagonal screw approx 4 mm reposition the lever in the desired position and retighten the screw Length adjustable lever 7H 10H To adjust the length of the lever unscrew the fixing screw of the lever Firmly retighten the screw after the length adjust...

Страница 5: ... checked and met The installation is executed according to the instructions The connection is executed correctly The cable is correctly executed and connected Check the free movement of the actuating element The safety component is not damaged Remove particles of dust and soiling Check cable entry and connections in de energised condition 5 2 Maintenance In case of correct installation in accordan...

Страница 6: ...ervice GmbH Am Grauen Stein 51105 Köln ID n 0035 Certificate number 01 220 4316 06 Notified body DEKRA EXAM GmbH Dinnendahlstraße 9 44809 Bochum ID n 0158 EU prototype test certificate BVS 09 ATEX E 152 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal The currently valid declaration of conformity can be downloaded from the internet a...

Отзывы: