1. About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the 

safe operation and disassembly of the the product. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional 

information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The product must be exclusively used in accordance with the versions 

listed below or for the applications authorised by the manufacturer. 

Detailed information regarding the range of applications can be found in 

the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.3  Settings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.4  Mounting of the actuating heads  . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.5  Actuation of the position switches  . . . . . . . . . . . . . . . . . . . . . . . . . .4

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .5

4.2  Contact variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5  Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

x.000 / 04.2019 / v

.A.   -   10121

1859-EN / K / 2019-04-24 / 

AE-Nr

. 10886

6  Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

7  EU Declaration of conformity

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 6

Original

Содержание EX-T 335

Страница 1: ...tire machine or plant The product must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific...

Страница 2: ...n in ac cordance with the relevant standards and the required safety level The entire concept of the control system in which the safety component is integrated must be validated to the relevant standards The safety technical data and features according to the applicable test certificate or possible other approvals are mentioned in the technical data 2 4 Technical data Designation in accordance wit...

Страница 3: ...the guidance of the actuating system The actuation of the switch beyond its end stop however must be avoided Please observe the recommendations regarding maximum impact energy actuating speed and tightening torque in the technical data Please observe the relevant requirements of the standards ISO 12100 ISO 14119 and ISO 14120 3 2 Dimensions All measurements in mm 76 40 5 30 7 3 5 3 60 66 5 30 5 6 ...

Страница 4: ... the inside of the arm Positioning the lever H 10 10 10 10 The roller lever can be repositioned over 360 on the toothed shaft in 10 steps Unscrew the hexagonal screw approx 4 mm reposition the lever in the desired position and retighten the screw Length adjustable lever 7H 10H To adjust the length of the lever unscrew the fixing screw of the lever Firmly retighten the screw after the length adjust...

Страница 5: ... checked and met The installation is executed according to the instructions The connection is executed correctly The cable is correctly executed and connected Check the free movement of the actuating element The safety component is not damaged Remove particles of dust and soiling Check cable entry and connections in de energised condition 5 2 Maintenance In case of correct installation in accordan...

Страница 6: ...ervice GmbH Am Grauen Stein 51105 Köln ID n 0035 Certificate number 01 220 4316 06 Notified body DEKRA EXAM GmbH Dinnendahlstraße 9 44809 Bochum ID n 0158 EU prototype test certificate BVS 09 ATEX E 152 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal The currently valid declaration of conformity can be downloaded from the internet a...

Отзывы: