background image

K. A. Schmersal GmbH & Co. KG

Möddinghofe 30, D - 42279 Wuppertal

Postfach 24 02 63, D - 42232 Wuppertal 

Phone:  +49 - (0)2 02 - 64 74 - 0 

Telefax:  +49 - (0)2 02 - 64 74 - 1 00

E-Mail: [email protected]

Internet: http://www.schmersal.com

Содержание EX-CSS 180

Страница 1: ... applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual labelled with the caution or warning symbol above the country specific installation standards as well as all prevailing safety regulat...

Страница 2: ... situation the diagnostic output will be switched off after approx 10 seconds The safety outputs are disabled when the fault is active for 1 minute Signal combination diagnostic output disabled and safety outputs still enabled can be used to shut down the machine in a controlled manner After fault rectification the error message is reset by opening and re closing the corresponding safety guard The...

Страница 3: ... can be fixed using the supplied M18 nuts A F 24 The max tightening torque of the supplied screws is 500 Ncm Alternatively the H18 fixing clamp accessory can be used for the fixation of the safety sensor A concealed mounting is possible however this reduces the switching distance The reduction will be lower when the sensor protrudes a few mm The CST 180 1 actuator has two fixing holes displaced by...

Страница 4: ...anent over voltage Under fault conditions the voltage must not exceed 60 V supply units according to IEC 60204 1 is recommended The safety outputs can be integrated into the safety circuit of the control system For applications of PL e control category 4 to ISO 13849 1 the safety outputs of the safety sensor or sensor of the chain must be wired to a safety monitoring module of the same control cat...

Страница 5: ...ed is load dependent 300 mΩ at 1 A current load i e max load of the safety outputs is 2 x 500 mA 30 mΩ at 100 mA current load i e 2x 50 mA load when a safety monitoring module is connected Power consumption of a safety sensor approx 30 mA Diagnostic output of a safety sensor max 50 mA An approx 200 m long sensor chain with 6 sensors 0 5 mm cable section and at 20 C features approx 2 V voltage drop...

Страница 6: ...sor can be readjusted before the safety outputs are disabled thus stopping the machine Errors in the coding of the actuator at the outputs of the sensor or in the sensor are signalled by the red LED After a short analysis of the active fault signalled by the red permanent signal the defined error is indicated by flash pulses The safety outputs are enabled in a delayed manner when the fault is acti...

Страница 7: ...d the full quality assurance system referred to in Appendix IV 2014 34 EU TÜV Rheinland Industrie Service GmbH Am Grauen Stein 51105 Köln ID n 0035 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal May 2 2017 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original...

Страница 8: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Отзывы: