3
AZM 161../..
Operating instructions
Solenoid interlock
EN
The entire concept of the control system, in which the
safety component is integrated, must be validated to the
relevant standards.
The user must evaluate and design the safety chain in
accordance with the relevant standards and the required
safety level.
2.4 Technical data
Standards:
IEC 60947-5-1, ISO 14119, BG-GS-ET-19
Enclosure:
glass-fibre reinforced thermo-
plastic, self-extinguishing
Actuator and locking bolt:
stainless steel 1.4301
Contact material:
Silver
Coding level according to ISO 14119:
low
Protection class:
IP67
Contact type:
Change-over with double break Zb,
galvanically separated contact bridges
Switching system:
A
acc. IEC 60947-5-1 slow action,
NC contact with positive break
Positive break travel:
10 mm
Positive break force:
10 N for each NC contact fitted
Connection:
screw terminals or cage clamps
or connector plug
Cable type:
flexible
Cable section:
min. 0.25 mm², max. 1.5 mm²
(including conductor ferrules)
Cable entry:
4 x M16
Holding force F:
2000 N
Latching force:
30 N for ordering suffix R
Actuating speed:
max. 2 m/s
Actuating frequency:
max. 1000 operations/h
Mechanical life:
> 1 million operations
Ambient temperature:
−25 °C … +60 °C
Electrical data:
Utilisation category:
AC-15, DC-13
Rated operating current/voltage I
e
/U
e
:
CC, SK, ST 4-pole: 4 A /230 VAC;
2.5 A / 24 VDC;
ST 8-pole: 2 A / 24 VDC
Rated impulse withstand voltage U
imp
:
CC, SK, ST 4-pole: 4 kV;
ST 8-pole: 0.8 kV
Rated insulation voltage U
i
:
CC, SK, ST 4-pole: 250 V;
ST 8-pole: 60 V
Thermal test current I
the
:
CC, SK, ST 4-pole: 6 A;
ST 8-pole: 2 A
Rated control voltage U
s
:
24 VAC/DC; 110/230 VAC
Magnet:
100% ED
Power consumption:
max. 10 W
Max. fuse rating:
6 A gG D-fuse
Required rated short-circuit current:
1000 A
Use Type 4X (Indoor Use) and 12 connector fittings.
Tightening torque rating: 4.4 lb in.
2.5 Safety classification
Standards:
ISO 13849-1
Envisaged structure:
- Basically:
applicable up to Cat. 1 / PL c
- With 2-channel usage and
fault exclusion mechanism*:
applicable up to Cat. 3 / PL d
with suitable logic unit
B
10d
NC contact:
2,000,000
B
10d
NO contact at 10% ohmic contact load:
1,000,000
Service life:
20 years
* If a fault exclusion to the 1-channel mechanics is authorised.
MTTF
B
d
x
x
h
s/h
3600
d
10d
op
op
op
n
0,1 x n
op
t
cycle
(Determined values can vary depending on the application-specific
parameters h
op
, d
op
and t
cycle
as well as the load.)
If multiple safety components are wired in series, the Performance
Level to ISO 13849-1 will be reduced due to the restricted error
detection under certain circumstances.
3. Mounting
3.1 General mounting instructions
Three mounting holes are provided for fixing the enclosure. The
solenoid interlock is double insulated. The use of an earth wire is not
authorised. The solenoid interlock must not be used as an end stop.
Any mounting position. The mounting position however must be chosen
so that the ingress of dirt and soiling in the used opening is avoided.
Unused actuator openings must be sealed with slot sealing plugs.
The safety component and the actuator must be permanently
fitted to the safety guards and protected against displacement
by suitable measures (tamperproof screws, gluing, drilling,
pinning).
Please observe the remarks of the standards ISO 12100,
EN 953 and ISO 14119.
3.2 Dimensions
All measurements in mm.
30
90
25
130
26
30
18
8
6
6
6
6
8
22,5
20
32
72
26
104
28