2.4  Technical data

Standards:

 

IEC 60947-5-1, ISO 14119, BG-GS-ET-19 

Enclosure:

 

glass-fibre reinforced thermo- 

plastic, self-extinguishing

Actuator and locking bolt:

 

stainless steel 1.4301

Contact material:

 Silver

Coding level according to ISO 14119:  

low

Protection class:

 IP67

Contact type:

 

Change-over with double break Zb,  

galvanically separated contact bridges

Switching system:

 

A

 acc. IEC 60947-5-1 slow action,  

NC contact with positive break

Positive break travel:

 

10 mm

Positive break force:

 

10 N for each NC contact fitted

Connection: 

screw terminals or cage clamps  

or connector plug

Cable type:

 flexible

Cable section:

 

min. 0.25 mm², max. 1.5 mm²  

(including conductor ferrules)

Cable entry:

 

4 x M16

Holding force F:

 

2000 N

Latching force:

 

30 N for ordering suffix R

Actuating speed:

 

max. 2 m/s

Actuating frequency:

 

max. 1000 operations/h

Mechanical life:

 

> 1 million operations

Ambient temperature:

 

−25 °C … +60 °C

Electrical data: 

Utilisation category:

 

AC-15, DC-13

Rated operating current/voltage I

e

/U

e

:

  CC, SK, ST 4-pole: 4 A /230 VAC;  

2.5 A / 24 VDC; 

ST 8-pole: 2 A / 24 VDC

Rated impulse withstand voltage U

imp

:

 

CC, SK, ST 4-pole: 4 kV;  

ST 8-pole: 0.8 kV

Rated insulation voltage U

i

:

 

CC, SK, ST 4-pole: 250 V;  

ST 8-pole: 60 V

Thermal test current I

the

 

CC, SK, ST 4-pole: 6 A;  

ST 8-pole: 2 A

Rated control voltage U

s

:

 

24 VAC/DC; 110/230 VAC

Magnet:

 

100% ED

Power consumption:

 

max. 10 W

Max. fuse rating:

 

6 A gG D-fuse

Required rated short-circuit current:

 

1000 A

Use Type 4X (Indoor Use) and 12 connector fittings.
Tightening torque rating: 4.4 lb in.

2.5  Safety classification

Standards: 

ISO 13849-1

Envisaged structure: 

 

- Basically: 

applicable up to Cat. 1 / PL c

 

-  With 2-channel usage and  

 

fault exclusion mechanism*: 

applicable up to Cat. 3 / PL d  

with suitable logic unit

B

10d

 NC contact: 

2,000,000

B

10d

 NO contact at 10% ohmic contact load: 

1,000,000

Service life: 

20 years

* If a fault exclusion to the 1-channel mechanics is authorised.

MTTF

B

d

x

x

h

s/h

3600

d

10d

op

op

op

n

0,1 x n

op

t

cycle

(Determined values can vary depending on the application-specific 
parameters h

op

, d

op

 and t

cycle

 as well as the load.)

If multiple safety components are wired in series, the Performance 
 Level to ISO 13849-1 will be reduced due to the restricted error 
 detection under certain circumstances.

3.  Mounting

3.1  General mounting instructions

Three mounting holes are provided for fixing the enclosure. The 
solenoid interlock is double insulated. The use of an earth wire is not 
authorised. The solenoid interlock must not be used as an end stop. 
Any mounting position. The mounting position however must be chosen 
so that the ingress of dirt and soiling in the used opening is avoided. 
Unused actuator openings must be sealed with slot sealing plugs.

The safety component and the actuator must be permanently 
fitted to the safety guards and protected against displacement 
by suitable measures (tamperproof screws, gluing, drilling, 
pinning).

Please observe the remarks of the standards ISO 12100, 
EN 953 and ISO 14119.

3.2  Dimensions

All measurements in mm.

30

90

25

130

26

30

18

8

6

6

6

6

8

22,5

20

32

72

26

104

28

Содержание AZM 161 Series

Страница 1: ...for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Furthe...

Страница 2: ...in switch is opened The safety switchgears are classified according to ISO 14119 as type 2 interlocking devices Manual release for set up maintenance etc The manual release is realised by turning the triangular key M5 triangular key available as accessory so that the locking bolt is pulled into the unlocking position Please ensure that jamming by external influence on the actuator is avoided The n...

Страница 3: ... voltage Us 24 VAC DC 110 230 VAC Magnet 100 ED Power consumption max 10 W Max fuse rating 6 A gG D fuse Required rated short circuit current 1000 A Use Type 4X Indoor Use and 12 connector fittings Tightening torque rating 4 4 lb in 2 5 Safety classification Standards ISO 13849 1 Envisaged structure Basically applicable up to Cat 1 PL c With 2 channel usage and fault exclusion mechanism applicable...

Страница 4: ... 72 52 13 21 41 42 22 14 A2 A1 71 51 63 64 72 52 A2 11 21 41 42 22 12 Q Q A1 71 51 63 64 72 52 11 21 41 42 22 12 A2 P Q AZM 161SK 12 03 AZM 161CC 12 03 A1 71 51 63 64 72 52 13 21 41 42 22 14 A2 Key A Positive break NC contact Monitoring the interlock according to ISO 14119 P Actuated Q Not actuated AZM 161ST with connector AZM 161ST 12 11 AZM 161ST 11 12 A1 A2 41 42 51 52 63 64 13 14 21 22 71 72 1...

Страница 5: ... previously checked and met 1 Fitting of the solenoid interlock and the actuator 2 Check the integrity of the cable entry and connections 3 Check the switch enclosure for damage 5 2 Maintenance A regular visual inspection and functional test including the following steps is recommended 1 Check for tight installation of the actuator and the switch 2 Remove particles of dust and soiling 3 Check cabl...

Страница 6: ... Wuppertal The currently valid declaration of conformity can be downloaded from the internet at www schmersal net 7 EU Declaration of conformity K A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal February 1 2016 ...