background image

6

Operating instructions

Solenoid interlock

AZM 161 AS

EN

System condition

Magnet input

AS-i D Out: 0

Channel 1

Yellow LED

Channel 2

Yellow LED

SaW code

Reset

AS-i FID

Red LED

Parameter port

P0

P1

P2

P3

Safety guard open

0

---

---

0

0

0

0

---

0

0

1

0

Safety guard closed

0

---

---

0

0

0

0

---

1

0

1

0

Safety guard locked

1

ON

ON

SaW code

---

1

1

1

0

Locking blocked

1

---

---

0

0

0

0

Flashes

1

0

1

1

Unlocking blocked

0

ON

ON

SaW code

Flashes

1

1

1

1

AZM 161 B ST-AS .A. 

B-variant, power to lock (magnet-operated locking)

System condition

Magnet input

AS-i D Out: 0

Channel 1

Yellow LED

Channel 2

Yellow LED

SaW code

Reset

AS-i FID

Red LED

Parameter port

P0

P1

P2

P3

Safety guard open

0

---

---

0

0

0

0

---

0

0

1

0

Safety guard closed

0

ON

ON

SaW code

---

1

0

1

0

Safety guard locked

1

ON

ON

SaW code

---

1

1

1

0

Locking blocked

1

ON

ON

SaW code

Flashes

1

0

1

1

Unlocking blocked

0

ON

ON

SaW code

Flashes

1

1

1

1

AZM 161 BZ ST-AS .A.  

BZ-variant, power to lock (magnet-operated locking)

System condition

Magnet input

AS-i D Out: 0

Channel 1

Yellow LED

Channel 2

Yellow LED

SaW code

Reset

AS-i FID

Red LED

Parameter port

P0

P1

P2

P3

Safety guard open

0

---

---

0

0

0

0

---

0

0

1

0

Safety guard closed

0

ON

---

HC1*

0

0

---

1

0

1

0

Safety guard locked

1

ON

ON

SaW code

---

1

1

1

0

Locking blocked

1

ON

---

HC1*

0

0

Flashes

1

0

1

1

Unlocking blocked

0

ON

ON

SaW code

Flashes

1

1

1

1

HC1

* AS-i half code 1 (AS-i SaW bit 0.1)

AZM 161 Z ST-AS   Z-variant, power to unlock (spring-operated locking)

System condition

Magnet input

AS-i D Out: 0

Channel 1

Yellow LED

Channel 2

Yellow LED

SaW code

Reset

AS-i FID

Red LED

Parameter port

P0

P1

P2

P3

Safety guard open

1

---

---

0

0

0

0

---

0

0

1

0

Safety guard closed

1

---

---

0

0

0

0

---

1

0

1

0

Safety guard locked

0

ON

ON

SaW code

---

1

1

1

0

Locking blocked

0

---

---

0

0

0

0

Flashes

1

0

1

1

Unlocking blocked

1

ON

ON

SaW code

Flashes

1

1

1

1

AZM 161 B ST-AS   B-variant, power to unlock (spring-operated locking)

System condition

Magnet input

AS-i D Out: 0

Channel 1

Yellow LED

Channel 2

Yellow LED

SaW code

Reset

AS-i FID

Red LED

Parameter port

P0

P1

P2

P3

Safety guard open

1

---

---

0

0

0

0

---

0

0

1

0

Safety guard closed

1

ON

ON

SaW code

---

1

0

1

0

Safety guard locked

0

ON

ON

SaW code

---

1

1

1

0

Locking blocked

0

ON

ON

SaW code

Flashes

1

0

1

1

Unlocking blocked

1

ON

ON

SaW code

Flashes

1

1

1

1

AZM 161 BZ ST-AS  BZ-variant, power to unlock (spring-operated locking)

System condition

Magnet input

AS-i D Out: 0

Channel 1

Yellow LED

Channel 2

Yellow LED

SaW code

Reset

AS-i FID

Red LED

Parameter port

P0

P1

P2

P3

Safety guard open

1

---

---

0

0

0

0

---

0

0

1

0

Safety guard closed

1

ON

---

HC1*

0

0

---

1

0

1

0

Safety guard locked

0

ON

ON

SaW code

---

1

1

1

0

Locking blocked

0

ON

---

HC1*

0

0

Flashes

1

0

1

1

Unlocking blocked

1

ON

ON

SaW code

Flashes

1

1

1

1

HC1

* AS-i half code 1 (AS-i SaW bit 0.1)

Содержание AZM 161 AS

Страница 1: ...ons listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety inst...

Страница 2: ...riants can be used as safety switch with interlocking function either as solenoid interlock for the position monitoring and locking of movable safety guards Interlocks with power to lock principle may...

Страница 3: ...on SaW AS interface outputs Bit 0 magnet control solenoid interlock Bit 1 Bit 3 no function Parameter port P0 actuator identified P1 solenoid interlock locked P2 magnet voltage in tolerance range P3 e...

Страница 4: ...soiling in the used opening is avoided Unused actuator openings must be sealed with slot sealing plugs The safety component and the actuator must be permanently fit ted to the safety guards and protec...

Страница 5: ...any time in which case the safety outputs are reactivated The safety guard must not be opened The redundancy and the Safety guard closed signal are not tested in this configuration To test these cond...

Страница 6: ...0 1 1 Unlocking blocked 0 ON ON SaW code Flashes 1 1 1 1 HC1 AS i half code 1 AS i SaW bit 0 1 AZM 161 Z ST AS Z variant power to unlock spring operated locking System condition Magnet input AS i D O...

Страница 7: ...ding the following steps is recommended 1 Check for a secure installation of the actuator and the switch 2 Remove particles of dust and soiling 3 Check cable entry and connections Adequate measures mu...

Страница 8: ...the component Interlocking device with electromagnetic interlock for safety functions with integrated AS i Safety at Work Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42...