30.10.06.00060
Status 02.2009
Index 01
Page 12/16
2008 J. Schmalz GmbH
J. Schmalz GmbH
Förder- u. Handhabungstechnik
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax.: +49(0)7443/2403-259
www.schmalz.com
2.) Pressure Setting Mode
2.1) Manual setting mode
Switching point ON OUT1:
P_1 (for NO) or n_1 (for NC)
Switching point OFF OUT1:
P_2 (for NO) or n_2 (for NC)
Switching point ON OUT2:
P_3 (for NO) or n_3 (for NC)
Switching point OFF OUT2:
P_4 (for NO) or n_4 (for NC)
*1.) The Display shows (P_*) at normal open mode and (n_*) at normal close mode. Pressure
setting value is shown normally and will not lead to pressure sensor pause or stop working.
*2.) Change pressure value:
Press <
“Up button”>, each press will increase one digit. Keep pressing <
>, the pressure
value will keep increasing.
Press <
„Down button“>, each press will decrease one digit. Keep pressing <
>, the
pressure value will keep decreasing.
2.2) Auto setting mode
Prepare auto setting mode at OUT1 switch.
(Under this mode, the device needs to be set repeatedly in order to reach the auto setting
value)
Prepare auto setting mode at OUT2 switch.
(Under this mode, the device needs to be set repeatedly in order to reach the auto setting
value)
In the auto setting mode the setting values ON and OFF are setted according to the following
calculation:
*1.) In case of without need of OUT1 pressure value setting, press <
+
> at the same time to
enter AP2 rather An2.
*2.) In case of without need of OUT2 pressure value setting, press <
+
> at the same time to
enter measure mode.
*3.) The Display shows AP* at normal open mode and AN* at normal close mode.