Schmalz VCMC-R QUICK Скачать руководство пользователя страница 4

ü

This symbol represents a prerequisite that must be met prior to an operational step.

4

This symbol represents an action to be performed.

ð

This symbol represents the result of an action.

Actions that consist of more than one step are numbered:

1. First action to be performed.

2. Second action to be performed.

2  Fundamental Safety Instructions

2.1  Safety

 CAUTION

Noise pollution from leakage

Hearing damage

4

Correct position.

4

Wear ear protectors.

 CAUTION

Falling product

Risk of injury

4

Securely attach the product at the site of operation.

4

Wear safety shoes (S1) and safety glasses when handling and mounting/dismounting the prod-
uct.

2.2  Intended Use

The mechanical clamp VCMC-R is used for clamping dry, rigid workpieces onto table grid plates. It may be used
only in combination with a suitable grid table. The VCMC is to be installed by the customer.

The VCMC-R is aligned with brackets and secured against horizontal slipping. Switching on the operating vacuum
fixes the clamp to the table. The workpiece is then clamped by means of a vertical stroke of the clamping disc.

To guarantee safe operation of the VCMC, ensure the following:

During installation, the clearance between the workpiece surface and the clamping disc must be no more
than 6 mm. Caution: crushing hazard!

Do not allow anyone to reach between the workpiece and the clamping disc during the lowering process.

When the operating vacuum is switched off and the vacuum circuit is vented, the clamping pressure on the work-
piece is released and the VCMC is released from the grid table.

The product is built in accordance with the latest standards of technology and is delivered in a safe operating con-
dition; however, hazards may arise during use.

The product is intended for industrial use.

Intended use includes observing the technical data and the installation and operating instructions in this manual.

2.3  Non-Intended Use

Schmalz accepts no liability for damages resulting from use other than as intended. In particular, the following are
considered non-intended use:

Use in potentially explosive atmospheres

Use in medical applications

2.4  Personnel Qualifications

Unqualified personnel cannot recognize dangers and are therefore exposed to higher risks!

1. Task only qualified personnel to perform the tasks described in these Operating instructions.

2. The product must be operated only by persons who have undergone appropriate training.

4 / 15

EN-US · 30.30.01.03049 · 00 · 10/21

Содержание VCMC-R QUICK

Страница 1: ...Schmalz GmbH 10 21 This document is protected by copyright J Schmalz GmbH retains the rights established thereby Reproduction of the contents in full or in part is only permitted within the limits of...

Страница 2: ...ption of Mechanical Clamp VCMC 5 3 1 1 Use 5 3 1 2 The Adjustment Mechanism 5 3 1 3 Clamping the Workpiece 5 3 2 Design of Mechanical Clamp VCMC 6 3 3 Near Field Communication NFC 6 4 Technical Data 7...

Страница 3: ...malfunctions that result from failure to heed these instructions If you still have questions after reading the technical documentation contact Schmalz Service at www schmalz com services 1 3 Type Plat...

Страница 4: ...e the following During installation the clearance between the workpiece surface and the clamping disc must be no more than 6 mm Caution crushing hazard Do not allow anyone to reach between the workpie...

Страница 5: ...ition as delivered 2 Use only original spare parts from Schmalz 3 The product must be operated only in perfect condition 3 Product Description 3 1 Description of Mechanical Clamp VCMC 3 1 1 Use The VC...

Страница 6: ...3 3 Near Field Communication NFC NFC Near Field Communication refers to a standard for wireless data transfer between different devices over short distances An NFC chip is integrated in the locking di...

Страница 7: ...sed The following parameters can be queried via NFC Product group Type Part number Index Serial number Year of manufacture encoded 4 Technical Data 4 1 General parameters Stroke length Z all 9 mm Dete...

Страница 8: ...and J Schmalz GmbH 6 Installation 6 1 Installation Instructions The VCMC R is designed for grid tables with grids measuring 30x30 40x40 and 50x50 and slot widths between 5 and 7 mm Mounting and remova...

Страница 9: ...lot widths from 5 mm Size 6 0 for slot widths from 6 mm Size 6 5 for slot widths from 6 5 mm Position R30 Position R40 Position R50 Grid dependent positions for positioning inserts and sealing frame A...

Страница 10: ...sure that there is an open vacuum feedthrough in the grid table within the sealing frame 5 Check the position The positioning inserts lock positively into the slots The VCMC R is in full contact with...

Страница 11: ...ism Turn the locking disc counterclockwise until the quick adjustment mechanism is completely opened 2 Releasing the catch of the quick adjustment mech anism Clasp the clamping disc with both hands an...

Страница 12: ...ping Range CAUTION When the clamping disc is lowered body parts may be present in the clamping range Crushing of body parts 4 Ensure that the clamping height is set so that the distance between the cl...

Страница 13: ...unterclockwise and remove it from the clamping disc 1 4 Screw the clamping disc clockwise onto the clamp 5 Open the quick adjustment mechanism see step 1 above 6 For the next steps see section Setting...

Страница 14: ...n be moved then it is not sufficiently tightly clamped Check the clamping height and ad just it if necessary If the clamping is sufficient then machining of the workpiece may commence 7 2 Machining Li...

Страница 15: ...3 NBR 55 Sealing frame for R50 Wearing part 10 Disposing of the Product CAUTION Flying parts resulting from opening the mechanical clamp and releasing the spring Serious injury 4 Open the mechanical c...

Отзывы: