Schmalz SCPSb-2 Скачать руководство пользователя страница 6

S

CHMALZ   

SCPSb

 

-

 

2

 

 

2-6

 

 

2  P

RODUCT 

O

VERVIEW

 

G

ENERAL DESCRIPTION OF FUNCTIONS

 

V

ACUUM GENERATION 

(

PICKING UP THE WORKPIECE

The ejector is designed for vacuum handling of parts in combination with suction systems.  
The  venturi  nozzle  is  activated  and  deactivated  using  the  “suction”  pilot  valve.  In  the  NO 
version, the  venturi nozzle  is deactivated  when  voltage is  applied.  In the NC  version, the 
venturi nozzle is activated when voltage is applied. 

When objects with dense surfaces are picked up, the integrated non-return valve prevents 
the vacuum from dropping. 

 

B

LOW

-

OFF 

(

DEPOSITING THE WORKPIECE

The vacuum circuit o

f the ejector is supplied with compressed air using the “blow off” pilot 

valve.This  ensures  that  the  vacuum  drops  quickly,  depositing  the  workpiece  quickly  as 
well. 

 

 

V

ERSIONS

 

Each ejector has a specific item designation (e.g. SCPSb-2-07-S4-NO). 

The item designation can be broken down as follows: 

 

Type 

Perfomance 
class 

Pneumatic

 

connection 

Electrical

 

connection 

Idle position 

SCPSb

 

2-07 

2-09 

2-14 

S4 

(2x D6) 

S4 

(2x D6) 

S2 

(D6 at 1, D8 at 2) 

 

Using the plug con-
nection of the pilot 
valves 

 

NO 

Normally open

 

NC 

Normally closed

 

 

 

E

LECTRICAL CONNECTION

 

Plugs  for  magnetic  valves  are  inserted  until  they  lock  into  place.  Press  the  lock  lever  to 
remove the plugs. 

 

 

 

 

Содержание SCPSb-2

Страница 1: ...Innovative Vacuum for Automation EN SCPSb 2 Eco Nozzle Technology Operating instructions 30 30 01 00664...

Страница 2: ...of Functions 3 8 General functions 3 8 Setting the blow off volume flow 3 8 4 Operating Mode 4 9 Mounting 4 9 Pneumatic connection 4 10 Electrical connection 4 10 5 Maintenance 5 11 General maintenanc...

Страница 3: ...s can be sucked in Compressed air can cause closed containers to explode A vacuum can cause closed containers to implode The ejector may only be operated with a silencer Never look into the exhaust ai...

Страница 4: ...ontrol components and feed back signals INTENDED USE The ejector is designed to generate a vacuum for gripping and transporting objects when used in conjunction with suction pads Neutral gases in acco...

Страница 5: ...e that the ejector is disconnected and depressurized and that it cannot be switched on again without authorization Personal injury or damage to the ejector may occur Protect the ejector from damage at...

Страница 6: ...nts the vacuum from dropping BLOW OFF DEPOSITING THE WORKPIECE The vacuum circuit of the ejector is supplied with compressed air using the blow off pilot valve This ensures that the vacuum drops quick...

Страница 7: ...ng operation Position Description Max tightening torque 1 Pilot valve Suction 0 2 Nm 2 Pilot valve Blow Off 0 2 Nm 3 Blow off valve screw 4 Vacuum connection label 2 V D6 SCPSb 07 10 D8 SCPSb 15 5 Com...

Страница 8: ...sed to set the blow off volume flow Turning the screw clockwise reduces the volume flow Turning the screw counterclockwise increases the volume flow The valve screw is equipped with a stop on both sid...

Страница 9: ...MOUNTING SCPSb 2 We recommend using washers when mounting the securing screws Position Description Max tightening torque 1 M4 securing screw 2 Nm 2 Top hat rail clamp for TS35 top hat rail incl plast...

Страница 10: ...he vacuum side is too small This leads to both a reduction in suction capacity and increased evacuation times Blow off times are also lengthened Hose lines must be laid without bends or crimps Only us...

Страница 11: ...aranteed in accordance with our general terms of trade and delivery The same applies to spare parts provided that these are original parts supplied by us We are not liable for any damage resulting fro...

Страница 12: ...ssure too low Increase operating pressure observe max limits Internal diameter of hose lines too small See recommended hose diameters Payload cannot be held securely Vacuum level too low Increase oper...

Страница 13: ...24 0V 1 The power supply must comply with the requirements of EN60204 protective extra low voltage 2 Parallel control of the suction and blow off valves 3 Separate control of the suction and blow off...

Страница 14: ...ert Porous PE Seals NBR Lubricants Silicone free Screws Galvanized steel MECHANISCHE PARAMETER Type Nozzle size Max vacuum 2 Suction rate 1 Max blow off capacity 1 Air con sumption 1 Sound level 1 Wei...

Страница 15: ...SC HMA LZ SCPSb 2 6 15 DIMENSIONS SCPSb 2 SCPSb 2 L L1 L2 L3 L4 B B1 H H1 H2 H3 H4 93 8 107 1 81 4 22 29 5 18 18 6 77 5 97 40 8 47 5 16 5 H5 d d1 d2 d3 X1 X2 Y1 Y2 5 5 4 4 6 6 2 6 36 9 16 12 12...

Страница 16: ...SC HMA LZ SCPSb 2 6 16 PNEUMATIC CIRCUIT DIAGRAMS SCPSb 2 NO SCPSb 2 NC...

Страница 17: ...SC HMA LZ SCPSb 2 7 17 7 CONFORMITY DECLARATION...

Страница 18: ...s were originally written in German and have been translated into English We reserve the right to make technical changes No responsibility is taken for print errors or other types of errors All inform...

Страница 19: ...ds Tel 31 0 74 255 5757 Fax 31 0 74 255 5758 schmalz schmalz nl Poland Tel 48 0 22 46 04970 Fax 48 0 22 87 40062 schmalz schmalz pl Russia Tel 7 495 9671248 Fax 7 495 9671249 schmalz schmalz ru Spain...

Отзывы: