![Schmalz SCPSb-2 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/schmalz/scpsb-2/scpsb-2_operating-instructions-manual_1212890012.webp)
S
CHMALZ
SCPSb
-
2
5-12
T
ROUBLESHOOTING
Fault
Possible cause
Solution
Vacuum level is
not reach or vacu-
um is created too
slowly
Silencer is dirty
Replace silencer
Leakage in hose line
Check hose connections
Leakage at suction pad
Check suction pad
Operating pressure too low
Increase operating pressure (observe max.
limits)
Internal diameter of hose
lines too small
See recommended hose diameters
Payload cannot be
held securely
Vacuum level too low
Increase operating pressure
(observe max. limits)
Suction pad too small
Select a larger suction pad
A
CCESSORIES
Designation
Article no.
Connection cable for Pilot valves
21.04.06.00086
Top-hat rail clamp for TS35 top-hat rail, incl. plastic tapping
screws (optional)
10.02.02.04149