Operating and Menu Concept
EN-US · 30.30.01.01961 · 00 · 06/19
21 / 68
4. Press the
button to save the modified value.
ð
The first digit is accepted and the second digit flashes.
5. Use the
button to set the second digit.
6. Press the
button to save the modified value.
ð
The second digit is accepted and the third digit flashes.
7. Use the
button to set the third digit.
8. Press the
button to save the modified value.
ð
If the value entered lies within the permissible value range, it is accepted and the modified parame-
ter is displayed.
ð
If the entered value does not lie within the permissible value range, this is briefly indicated on the
display [
1nc
] and the new value is not accepted.
If input is interrupted for longer than 1 minute or if no input is made, the display automatically switches
to the measurement display.
6.3 Extended Functions menu (EF)
An “Extended Functions” menu (EF) is available for applications with special requirements.
6.3.1 Functions in the Extended Functions menu (EF)
The following table shows an overview of the display codes and parameters in the “Extended Functions”
menu:
Display
code
Parameter
Possible settings
Explanation
ctr
Energy-saving
function
oFF
on
on5
Control function off
Control active
Control with leak monitoring active
dc5
Deactivate
auto. control
shutoff
NO
YE5
Suppresses the automatic valve protection function
when set to
YE5
.
Cannot be activated when
Ctr
=
off
.
t-1
Max. permissi-
ble evacuation
time
configurable be-
tween 0.01 and
9.99 seconds in
steps of 0.01
off
Permitted evacuation time
No monitoring
-L-
Max. permissi-
ble leakage
Values config-
urable between
0
and
999
Permitted leakage
Unit: millibar per second
bLo
Blow-off func-
tion
-E-
1-t
E-t
Externally controlled
Internally controlled (triggered internally, time can
be set)
Externally controlled (triggered externally, time can
be set)
0u2
Output func-
tion
no
nc
Normally open contact [
NO
]
Normally closed contact [
NC
]
P-n
Output type
PNP
NPN
Output
PNP switch
NPN switch